Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 17948.5-2016 English PDF

US$294.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17948.5-2016: Rotating electrical machines -- Functional evaluation of insulation systems -- Test procedures for form-wound windings -- Multifactor evaluation by endurance under simultaneous thermal and electrical stresses
Status: Valid

GB/T 17948.5: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 17948.5-2016294 Add to Cart 3 days Rotating electrical machines -- Functional evaluation of insulation systems -- Test procedures for form-wound windings -- Multifactor evaluation by endurance under simultaneous thermal and electrical stresses Valid
GB/T 17948.5-2007599 Add to Cart 3 days Rotating electrical machines -- Functional evaluation of insulation systems -- Test procedures for form-wound windings -- Multifactor functional evaluation -- Endurance under combined thermal and electrical stresses of insulation systems used in machines Obsolete

Similar standards

GB/T 20834   GB/T 20833.1   GB/T 20835   GB/T 17948.7   GB/T 17948.4   GB/T 17948.6   

Basic data

Standard ID: GB/T 17948.5-2016 (GB/T17948.5-2016)
Description (Translated English): Rotating electrical machines -- Functional evaluation of insulation systems -- Test procedures for form-wound windings -- Multifactor evaluation by endurance under simultaneous thermal and electrical stresses
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K20
Classification of International Standard: 29.160.01
Word Count Estimation: 15,111
Date of Issue: 2016-02-24
Date of Implementation: 2016-09-01
Older Standard (superseded by this standard): GB/T 17948.5-2007
Regulation (derived from): National Standard Announcement No
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 17948.5-2016: Rotating electrical machines -- Functional evaluation of insulation systems -- Test procedures for form-wound windings -- Multifactor evaluation by endurance under simultaneous thermal and electrical stresses



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rotating electrical machines - Functional evaluation of insulation systems - Test procedures for form-wound windings - Multifactor evaluation by endurance under simultaneous thermal and electrical stress ICS 29.160.01 K20 National Standards of People's Republic of China Replacing GB/T 17948.5-2007 Functional Evaluation of Rotating Motor Insulation Structure Forming Winding Test Procedure Thermal, Multi - factor Evaluation of Comprehensive Stress Durability enduranceundersim intervalsousthermalandelectricalstresses Lt;/RTI & thermalandelectricalstresses, IDT) 2016-02-24 release.2016-09-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface I Introduction III 1 Scope 1 2 normative reference document 1 3 Overview of test procedures 1 4 test 3 5 aging sub - cycle 4 6 Processing and Diagnosis Subdivision 5 7 End criteria 7 Analysis of data, reports and assessments Reference 8

Foreword

"Rotary motor insulation structure functional assessment" is divided into seven parts. Scatter - winding test procedure - Thermal evaluation and classification (GB/T 17948.1); - Scattered winding test procedure changes and classification of insulation components replacement (GB/T 17948.2); - Test rules for forming windings - Thermal evaluation and classification (GB/T 17948.3); - Specification for voltage durability of forming winding test procedures (GB/T 17948.4); - Code of test for forming windings - Multi - factor assessment of thermal and electrical stress durability (GB/T 17948.5); Test procedure for forming winding - Thermo - mechanical durability (GB/T 17948.6). --- General (GB/T 17948.7); This part is GB/T 17948.5. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part uses the translation method equivalent to the use of IEC /T S60034-18-33..2010 "Rotary motor insulation structure functional assessment molding Winding test procedures for thermal and electrical comprehensive stress and durability of multi - factor assessment "(English version). This part of the replacement GB/T 17948.5-2007 "Rotary motor insulation structure functional evaluation Molding winding test procedures Multi-factor work Energy assessment 50MVA, 15kV and below the electrical insulation structure of thermal, electrical comprehensive stress and durability ", compared with GB/T 17948.5-2007, In addition to editorial changes, the main technical changes are as follows. --- modified the standard name; - modified the scope of the standard (see Chapter 1, Chapter 1 of the.2007 edition); - increased processing and diagnostic sub-cycles (see 3.4.3); - Deletion of Table 1 aging sub-cycle identification (see Table 1 of.2007 edition); --- modified the heating method (see 3.5.1,.2007 version 3.6.1); - to modify the duration of the aging sub-cycle (see 3.8, 3.8 of.2007); - Added baseline processing factors (see 3.8.2); --- modified the acceleration factor (see 5.1.2,.2007 version 5.1.1); Amend Table 1 (see Table 1 in Table 1,.2007); --- 5.1.2 to 5.1.4 (see 5.1.2 to 5.1.4 for.2007); --- modified 5.4 (see 5.3,.2007 version 5.3); --- modified 5.5 (see 5.4,.2007 version 5.4); - 6.1.3, 6.1.4 (see 6.1.3, 6.1.4 for.2007); - 6.2.3, 6.2.4 (see 6.2.3, 6.2.4 of.2007); - 6.3.3, 6.3.4 (see 6.3.3, 6.3.4 for.2007); --- modified 6.5 (see 6.5,.2007 version 6.4); --- Added Chapter 7 (see Chapter 7); - Appendix A has been deleted (see Appendix A of the.2007 edition); --- Added references (see references). And the normative reference in this part of the international standards are consistent with the relationship between China's standards are as follows. Classification of electrical insulation heat resistance (IEC 60085..2004, IDT); GB/T . Evaluation and identification of electrical insulation structures (IEC 60505..1999, IDT); GB/T . --- GB/T 22715 AC motor stator forming coil impact voltage level (IEC 60034-15..2009, IDT); --- GB /Z22720.2-2013 Rotary motor voltage-type inverter-powered rotating motor resistance to partial discharge electrical insulation structure (Type II) identification and accreditation test (IEC /T S60034-18-42..2008, IDT); Guide for statistical analysis of electrical insulation breakdown data (IEC 62539..2007, IDT) GB/T 29310-2012. This part is made by China Electrical Equipment Industry Association. This part is headed by the National Committee for Standardization of Rotating Electric (SAC/TC26). This part is responsible for the drafting of the unit. Shanghai Institute of Electrical Science (Group) Co., Ltd., Zhejiang Xi Ma Motor Co., Ltd., Shandong Hua Li Machinery Group Co., Ltd., Suzhou Taihu Electric New Materials Co., Ltd., Zhejiang Jinlong Motor Co., Ltd., Suzhou Kuifeng Electric Insulation Systems Co., Ltd., Shanghai Dezhao Electric Co., Ltd., Yongji new speed motor electrical limited liability company, Shanghai motor system Energy - saving Engineering Technology Research Center Co., Ltd., Shanghai Electrical Equipment Testing Institute. This part participates in the drafting unit. Anhui Wannan Electric Co., Ltd., Hangzhou MiG Motor Co., Ltd., CSR Zhuzhou Motor Co., Ltd. Division, Zhuzhou era of electrical insulation limited liability company, Xiangtan Electric Co., Ltd. The main drafters of this part. Zhang Shengde, Zhao Chao, Yang Xianfang, Wang Qingdong, Zhang Chunqi, Ye Ye, Yuan Shizhen, Chen Xiangen, Zhang Shandi, Huang Huijie. This part of the previous version of the standard to replace the release of the situation. --- GB/T 17948.5-2007.

Introduction

IEC 60034-18-1 The general principles for the evaluation and classification of insulation structures for rotating electrical machines are presented. This part only applies to the forming winding insulation structure and focuses on the thermal, electrical aging of the multi-factor assessment. Functional Evaluation of Rotating Motor Insulation Structure Forming Winding Test Procedure Thermal, Multi - factor Evaluation of Comprehensive Stress Durability

1 Scope

This section specifies the evaluation procedure for the insulation structure while subjected to thermal and electrical stress durability tests. The test procedures in this section apply AC motor with or for the design of the winding insulation structure, the test protocol provides a benchmark and the structure under consideration in the voltage and temperature synthesis of the performance In contrast, temperature and voltage are used separately to evaluate performance in the past. The selected temperature and voltage should be made for the structure to be evaluated and the reference structure Within the appropriate time range and under actual stress. The test results of the structure to be evaluated indicate whether it is better or worse Run the empirical structure of the benchmark, but can not be used to calculate the operating life. The evaluation of this part does not include the stress gradient. The test procedures in this section do not apply to determining the interaction of heat and electrical stresses during aging and to determine the durability curve. If needed For additional information on the interaction or in order to determine the durability curve, it is necessary to do further testing, the temperature is constant at different voltages Perform an electrical aging or constant voltage at different temperatures for thermal aging.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 17948.7-2016 General specification for functional evaluation of insulating structures for rotating electrical machines (IEC 60034-18-1..2010, IDT) IEC 60034-15 AC motor stator forming coil impact voltage level (Rotatingelectricalmachines-Part 15. Impulsevoltagewithstandlevelsofform-woundstatorcoilsforrotatinga.c.machines) IEC /T S60034-18-42 Rotary motor Voltage-type inverter-powered rotating electric machine Resistive to partial discharge Electrical insulation structure (type II) Of the identification and accreditation test (Rotatingelectricalmachines-Part 18-42. Qualificationandacceptancetestsfor partialdischargeresistantelectricalinsulationsystems (Type II) usedinrotatingelectricalmachines fedfromvoltageconverters) IEC 60085 Electrical Insulation Assessment and Design (Electricalinsulation-Thermalevaluationanddesigna- tion IEC 60505 Evaluation and identification of electrical insulation systems (Evaluation and Quintification ofelectricalinsulationsys- tems) IEC 62539 Guidelines for Statistical Analysis of Electrical Insulation Breakdown Data (Guideforthestatisticalanalysisofelectricalinsu- lationbreakdowndata

3 Overview of test procedures

3.1 Relationship with other standards Unless otherwise recommended in this section, the principles of GB/T 17948.7-2016 and IEC 60505 should be followed. 3.2 Test procedures Tests can be carried out in accordance with the complete or single-point multi-factor test procedure for simultaneous application of temperature and voltage. The single-point test procedure provides only
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17948.5-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17948.5-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17948.5-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17948.5-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 17948.5-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17948.5-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.