GB/T 17606-2009 English PDFUS$229.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 17606-2009: Determination of sulfur in crude-oil by energy-dispersive X-ray fluorescence spectrometry Status: Valid GB/T 17606: Historical versions
Basic dataStandard ID: GB/T 17606-2009 (GB/T17606-2009)Description (Translated English): Determination of sulfur in crude-oil by energy-dispersive X-ray fluorescence spectrometry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: E21 Classification of International Standard: 75.040 Word Count Estimation: 10,142 Date of Issue: 2009-04-08 Date of Implementation: 2009-11-01 Older Standard (superseded by this standard): GB/T 17606-1998 Adopted Standard: ASTM D4294-2003, MOD Regulation (derived from): National Standard Approval Announcement 2009 No.4 (Total No.144) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard applies to the determination of total sulfur content of crude oil. Determination of the mass fraction of sulfur content in the range of 0. 0150% to 5. 00%. This standard applies to water mass fraction of less than 0. 5% of the crude oil samples, oil samples dehydrated under water if the mass fraction of more than 0. 5%, can not destroy the integrity of the sample. The water content of crude oil according to GB/T 8929-2006 for testing. GB/T 17606-2009: Determination of sulfur in crude-oil by energy-dispersive X-ray fluorescence spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of sulfur in crude-oil by energy-dispersive X-ray fluorescence spectrometry ICS 75.040 E21 National Standards of People's Republic of China Replacing GB/T 17606-1998 Determination of sulfur content in crude oil Energy dispersive X- ray fluorescence spectrometry Posted 2009-04-08 2009-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis revised standard adopts ASTMD4294.2003 "Petroleum and Petroleum Products Standard Test Method for Determination of sulfur emitted energy dispersive X- Ray fluorescence spectroscopy "(in English). This standard is based on ASTMD4294. redrafted 2003. This standard ASTMD4294.2003 main differences are as follows. --- ASTMD4294.2003 name for the "oil and petroleum products in the Standard Test Method for Determination of sulfur emitted energy dispersive X- Ray fluorescence spectrometry, "this standard entitled" Determination of sulfur content in crude oil energy dispersive X- ray fluorescence spectrometry "; --- ASTMD4294.2003 for petroleum and petroleum products, this standard applies to crude oil; --- This standard applies to moisture content does not exceed 0.5% of the crude oil sample; --- This standard does not adopt ASTMD4294.2003 specifically described with respect to petroleum products. This standard replaces GB/T 17606-1998 "Determination of sulfur content in crude oil energy dispersive X- ray fluorescence spectrometry." This standard GB/T 17606-1998 and main technical differences are as follows. --- The standard "range 1", the mass fraction of sulfur content measurement range from GB/T 17606-1998 in "~ 0.05% 5.00% "is replaced by" 0.0150% to 5.00% "; --- This standard adds "4 interference"; --- This standard GB/T 17606-1998 in "Reagent 4" to "6 reagents and materials"; --- GB/T 17606-1998 specified with nitrogen to make the optical path, the optical path of the standard is no longer requested; --- GB/T 17606-1998 in calibration standards into three groups of 14, 10 of the standard into two groups; --- GB/T 17606-1998 There are no loading problems like heavy oil and heavy oil will be described, the present standard adds this part; --- GB/T no quality control of the narrative 17606-1998, the present increase in the standard "13 Quality Control"; --- The standard by ASTMD4294.2003 Dui GB/T 17606-1998 in "9 Precision" in the formula has been modified. The standard proposed by China National Petroleum Corporation. This standard by the National Standardization Technical Committee of Oil and Gas. This standard was drafted. China Petroleum Daqing Oilfield Engineering Co., Ltd. Analysis and Testing Center, China Petrochemical Chemical Research Institute of Petroleum, China Petroleum Dalian Petrochemical Company Environmental Quality Inspection Center, in northwest China Petroleum Geology Center and petrochemical laboratories. The main drafters of this standard. Li Jicheng, Gao Ping, in infants, Jiangqi Guang, Li snow. This standard was first published in 1998. Determination of sulfur content in crude oil Energy dispersive X- ray fluorescence spectrometry1 Scope1.1 standard applies to the determination of total sulfur content of crude oil, sulfur content measured in the range of 0.0150% to 5.00%. 1.2 This standard applies to moisture content does not exceed 0.5% of the crude oil sample, if the crude oil sample moisture content exceeds 0.5%, to In the case of the sample without destroying the integrity of dehydration. The water content of crude oil according to GB/T 8929-2006 for testing. At a concentration of 1.3 units of International System of Units defined as a standard, the preferred sulfur content per unit of mass fraction. 1.4 This standard does not list all of the security problems, users should establish some appropriate security measures and practical management system to ensure that Safety, prevention knowledge, see Chapter 5.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 4075-2003 Sealed radioactive sources - General requirements and classification GB/T 4756-1998 Petroleum liquid manual sampling method GB/T 8929-2006 Determination of water content of crude oil distillation3 Methods SummaryThe sample is placed in X- ray beam emitted by the source, the measurement of sulfur characteristic X- ray spectral intensity and spectral intensity cumulative pre Good spectral intensity of the standard sample is prepared in the first comparison, and sulfur content of the samples should be within a known calibration standard of the sulfur content in the range to give Samples with sulfur content mass fraction expressed.4 Interference4.1 When the crude oil sample other elements emit X- rays, producing a spectral interference, the detector can not detect the correct emission of sulfur emitted X- Line, resulting in a spectral superposition. The aqueous sample, alkyl lead, silicon, phosphorus, calcium, potassium, and halides, sulfur content exceeds one-tenth or Several hundred milligrams per kilogram, it will produce spectral interferences. The device according to the manufacturer's operating instructions to calibrate the instrument to eliminate interference. 4.2 Changes in the concentration of elements in the sample matrix can change directly affects absorption of X- rays, thus changing the measurement result of each element fruit. This interference usually occurs in X- ray fluorescence analysis, but not spectral interference. 4.3 Some instruments equipped with noise reduction software, can automatically check and reduce interference. Crude oil sample 4.4 components are quite different with the white oil of 8.1, the matrix material composition can be selected with the same or similar components Sample analysis.5 InstrumentsEnergy dispersive X- ray fluorescence spectrometer, as long as the structural integrity of the design of energy-dispersive X- ray fluorescence spectrum analyzer can make Use, the instrument should have at least the following components. 5.1 X- ray emission source, its energy is higher than 2.5keV. Warning. In addition to other precautions, the use of radioactive sources, should be in accordance with the requirements of GB 4075-2003 well shielded to avoid ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 17606-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 17606-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 17606-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 17606-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 17606-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17606-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |