GB/T 17494-2023 English PDFUS$419.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 17494-2023: Diagnostic techniques for equine infectious anemia Status: Valid GB/T 17494: Historical versions
Basic dataStandard ID: GB/T 17494-2023 (GB/T17494-2023)Description (Translated English): Diagnostic techniques for equine infectious anemia Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: B41 Classification of International Standard: 11.220 Word Count Estimation: 22,295 Date of Issue: 2023-09-07 Date of Implementation: 2024-04-01 Older Standard (superseded by this standard): GB/T 17494-2009 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 17494-2023: Diagnostic techniques for equine infectious anemia---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.ICS 11.220 CCSB41 National Standards of People's Republic of China Replace GB/T 17494-2009 Diagnostic Technology for Equine Infectious Anemia Published on 2023-09-07 2024-04-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee Table of contentsPreface III Introduction IV 1 Scope 1 2 Normative reference documents 1 3 Terms and Definitions 1 4 Abbreviations 1 5 Laboratory biosafety measures 2 6 Clinical Diagnosis 2 7 Sample collection, storage and transportation3 8 Real-time PCR 4 9 Virus isolation and identification5 10 Agar gel immunodiffusion test 6 11 Indirect ELISA 8 12 Competitive ELISA 10 13 Western blot assay 11 14 Comprehensive judgment 13 Appendix A (normative) Preparation of reagents 14 Appendix B (informative) Real-time fluorescence PCR primers and probes 16 Appendix C (informative) Preparation of real-time fluorescence PCR positive control plasmid 17ForewordThis document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document replaces GB/T 17494-2009 "Indirect ELISA Diagnostic Technology for Equine Infectious Anemia" and is the same as GB/T 17494-2009 In comparison, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Added clinical diagnosis of equine infectious anemia (see Chapter 6); --- Added real-time fluorescence PCR detection of equine infectious anemia virus (see Chapter 8); ---Added the isolation and identification of equine infectious anemia virus (see Chapter 9); ---Added equine infectious anemia agar gel immunodiffusion test (see Chapter 10); ---Changed the indirect ELISA for equine infectious anemia (see Chapter 11, Chapter 4 and 5 of the.2009 edition); ---Added equine infectious anemia competition ELISA (see Chapter 12); ---Added equine infectious anemia immunoblotting test (see Chapter 13); Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document is proposed by the Ministry of Agriculture and Rural Affairs of the People's Republic of China. This document is under the jurisdiction of the National Animal Health Standardization Technical Committee (SAC/TC181). This document was drafted by. Harbin Veterinary Research Institute of the Chinese Academy of Agricultural Sciences, Xinjiang Uygur Autonomous Region Animal Disease Prevention and Control Center, Guangzhou Customs of the People's Republic of China, China Agricultural University, Beijing Customs of the People's Republic of China. The main drafters of this document. Hu Zhe, Wang Xiaojun, Guo Wei, Lin Yuezhi, Wang Xuefeng, Wang Wen, Chen Ru, Wang Qin, and Bai Yaduo. The previous versions of this document and the documents it replaces are as follows. ---First published as GB/T 17494-2009 in.2009; ---This is the first revision.IntroductionCategory II animal diseases stipulated in the "List of Epidemic Diseases" (2022). EIAV only infects animals of the genus Equus, of which horses are the most susceptible. Infected animals are the main source of infection. After EIAV infects the host, the virus will The body's genome is integrated into the host cell genome, causing persistent host infection and lifelong virus transmission. Clinically, sick animals may show repeated fever, Anemia, jaundice, hemorrhage, edema and emaciation are the characteristics of the disease. However, a certain proportion of horses and most donkeys and mules do not show obvious clinical symptoms after infection. As latent virus carriers. There is currently no available vaccine for this disease. The diagnosis of this disease requires laboratory diagnosis. EIAV belongs to reverse transcription After entering the host cell, the virus and EIAV replicate in the early stage under the action of viral reverse transcriptase to form double-stranded viral DNA (often called provirus). DNA), the proviral DNA is further integrated into the host chromosome under the action of the virus-encoded integrase. EIAV proviral DNA It is relatively stable in the infected host and is often used as a target for viral nucleic acid detection. There are relatively few EIAV genome sequences in different regions of the world. There is a big difference. The nucleic acid detection method used in this document is a universal real-time fluorescence PCR method suitable for different current strains. Diagnostic Technology for Equine Infectious Anemia1 ScopeThis document describes the clinical diagnosis of EIA, real-time fluorescence PCR, virus isolation and identification, agar gel immunodiffusion test, indirect Methods of ELISA, competitive ELISA, and western blot assays. This document applies to the diagnosis, quarantine, surveillance and epidemiological investigation of EIA.2 Normative reference documentsThe contents of the following documents constitute essential provisions of this document through normative citations in the text. Among them, dated references For referenced documents without dates, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document. document. GB/T 6682 Specifications and test methods for water used in analytical laboratories GB 19489 General requirements for laboratory biosafety NY/T 541 Technical specifications for collection, storage and transportation of veterinary diagnostic samples3 Terms and definitionsThere are no terms or definitions to be defined in this document.4 AbbreviationsThe following abbreviations apply to this document. BCA. Bicinchoninic Acid OD value. optical density value (OpticalDensity) Electrophoresis) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 17494-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 17494-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 17494-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 17494-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 17494-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17494-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |