Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 17286.2-2016 English PDF

US$474.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17286.2-2016: Liquid hydrocarbons -- Dynamic measurement -- Proving systems for volumetric meters -- Part 2: Pipe provers
Status: Valid

GB/T 17286.2: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 17286.2-2016474 Add to Cart 3 days Liquid hydrocarbons -- Dynamic measurement -- Proving systems for volumetric meters -- Part 2: Pipe provers Valid
GB/T 17286.2-1998919 Add to Cart 4 days Liquid hydrocarbons. Dynamic measurement. Proving systems for volumetric meters. Part 2: Pipe provers Obsolete

Similar standards

GB/T 18604   GB/T 23258   GB/T 21447   GB/T 43926   GB/T 17286.1   GB/T 17286.3   

Basic data

Standard ID: GB/T 17286.2-2016 (GB/T17286.2-2016)
Description (Translated English): Liquid hydrocarbons -- Dynamic measurement -- Proving systems for volumetric meters -- Part 2: Pipe provers
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: E98
Word Count Estimation: 25,228
Date of Issue: 2016-12-30
Date of Implementation: 2017-07-01
Older Standard (superseded by this standard): GB/T 17286.2-1998
Regulation (derived from): National Standard Notice No.27 of 2016
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 17286.2-2016: Liquid hydrocarbons -- Dynamic measurement -- Proving systems for volumetric meters -- Part 2: Pipe provers


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Liquid hydrocarbons - Dynamic measurement - Proving systems for volumetric meters - Part 2. Pipe provers ICS 75.180.30 E98 National Standards of People's Republic of China Replacing GB/T 17286.2-1998 Dynamic measurement of liquid hydrocarbons Volumetric metering system Part 2. volume tube volumetricmeters-Part 2. Pipeprovers (ISO 7278-2. 1988, IDT) 2016-12-30 release 2017-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface III Introduction IV 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 4 System Description 2 5 basic performance requirements 6 6 Equipment 7 7 design of the volume tube 9 8 Installation 11 9 test 12 Appendix A (normative) A volume tube 17 with four detection switches Appendix B (informative) Example of calculation of design parameters for volume tube 20

Foreword

GB/T 17286 "Liquid Hydrocarbon Dynamic Measurement Volume Metering Flowmeter Verification System" is divided into the following four parts. - Part 1. General principles; Part 2. Volume tube; Part 3. Pulse insertion technology; - Part 4. Guide for volume tube operator. This part is part 2 of GB/T 17286. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part of the replacement GB/T 17286.2-1998 "Dynamic measurement of liquid hydrocarbon volume measurement flowmeter Verification system Part 2. Volume tube". And GB/T 17286.2-1998 in the technical content of the main changes are as follows. --- deleted ISO preface; - ISO 4267-2 was added to the normative reference file; --- in the normative reference file to delete the abolition of GB/T 17290, changed to ISO 8222; --- in the preface to delete the 5.1 volume tube test flow meter repeatability description; --- The reverberation speed of the two-way volume tube in 7.4.3 is re-described; --- some of the standard inaccurate, non-standard statements were modified; - the English standard is given in the original standard. This part uses the translation method equivalent to ISO 7278-2. 1988 "Liquid Hydrocarbon Dynamic Measurement Volume Metering Flowmeter Verification System Section 2 Part. volume tube ". And this part of the normative reference documents have a corresponding relationship between China's documents are as follows. GB/T 17286.3-2010 Dynamic measurement of liquid hydrocarbon volume measurement flowmeter verification system - Part 3. Pulse insertion technology (ISO 7278.3..1998, IDT) Liquid hydrocarbon volume measurement - Turbine flowmeter metering system (ISO 2715. 1981, IDT) GB/T 17289-2009 Petroleum liquids and gases - Measurement standard reference conditions (neqISO 5024. 1976) GB/T 17291-1998. This part of the National Oil and Gas Standardization Technical Committee (SAC/TC355) proposed and centralized. This part of the drafting unit. China National Petroleum Corporation Metrology and Testing Institute. This part of the main drafters. Cui Jinghai, An Shumin, Sun Ce, Yang Xiaoping, Zhao Chenghai. This part of the previous version of the standard to replace the release of the situation. --- GB/T 17286.2-1998.

Introduction

The volumetric tube is a flow standard device for verifying the liquid flowmeter. This section covers the basic structure and technical performance requirements of the volumetric tube, Guide its design, installation and verification. This standard relates to the volume tube is a dynamic start and dynamic stop test equipment, the fluid in the quarantine period Continuous flow through the volume tube, the flowmeter can work in the normal test. This type of volumetric tube includes. replaceer, standard pipe section, Detection switch three parts. When the displacer enters the ball (or separation) zone with the fluid, the fluid flows through the bypass and the displacer stops run. According to the principle of this part, you can create a fixed or movable volume tube. The standard pipe section of the volumetric tube may be straight pipe or elbow (U-type), can be designed so that the displacer around a closed loop in one direction (one-way), can also be designed in two directions Line (two-way). Dynamic measurement of liquid hydrocarbons Volumetric metering system Part 2. volume tube

1 Scope

This part of GB/T 17286 gives technical guidelines for the design, installation and verification of volume tubes. This section does not include volume tube verification and A detailed calculation method for flowmeter verification. This section applies to different liquids, different types of flowmeters, and volume tubes that are tested using different methods. This part does not apply to small volume tubes.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. ISO 2715 Liquid hydrocarbon volume measurement Turbine metering system (Liquidhydrocarbons-Volumetricmeasure- mentbyturbinemetersystems ISO 4267-2 Petroleum and liquid petroleum products - Calculation of oil volume - Part 2. Dynamic metering (Petroleumandliquidpetro - leumproducts-Calculationofoilquantities-Part 2. Dynamicmeasurement) ISO 5024 Petroleum liquid and gas metering standards Reference conditions (Petroleumliquidsandliquefiedpetroleumgases measurement-standardreferenceconditions ISO 7278-3 Liquid hydrocarbon dynamic measurement - Volume metering system - Verification system - Part 3. Liquid - drocarbonsdynamicmeasurement-Provingsystemsforvolumetricmeters-Part 3. Pulseinterpola- tion techniques ISO 8222 oil measurement system calibration standard gauge temperature correction (Petroleum measurementsystems-Cali- bration-temperaturecorrectionsforusewithvolumetricreferencemeasuringsystems)

3 terms and definitions

The following terms and definitions apply to this document. 3.1 Standard volume basevolume The volume of the standard pipe section of the volumetric tube (ie, the pipe section between the two detection switches) under the specified standard reference conditions. 3.2 K factor Kfactor The ratio of the number of electronic pulses emitted by the flowmeter to the volume of the liquid through the flowmeter during the test run. 3.3 Flow meter coefficient The ratio of the actual volume of the liquid passing through the flow meter to the flow rate of the flow meter.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17286.2-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17286.2-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17286.2-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17286.2-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 17286.2-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17286.2-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.