Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 17286.1-2016 English PDF

US$194.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17286.1-2016: Liquid hydrocarbons dynamic measurement proving systems for volumetric meters -- Part 1: General principles
Status: Valid

GB/T 17286.1: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 17286.1-2016194 Add to Cart 3 days Liquid hydrocarbons dynamic measurement proving systems for volumetric meters -- Part 1: General principles Valid
GB/T 17286.1-1998319 Add to Cart 3 days Liquid hydrocarbons. Dynamic measurement. Proving systems for volumetric meters. Part 1: General principles Obsolete

Similar standards

GB/T 18604   GB/T 23258   GB/T 21447   GB/T 43926   GB/T 17286.2   GB/T 17286.3   

Basic data

Standard ID: GB/T 17286.1-2016 (GB/T17286.1-2016)
Description (Translated English): Liquid hydrocarbons dynamic measurement proving systems for volumetric meters -- Part 1: General principles
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: E98
Classification of International Standard: 75.180.30
Word Count Estimation: 10,180
Date of Issue: 2016-12-30
Date of Implementation: 2017-07-01
Older Standard (superseded by this standard): GB/T 17286.1-1998
Regulation (derived from): National Standard Notice No.27 of 2016
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 17286.1-2016: Liquid hydrocarbons dynamic measurement proving systems for volumetric meters -- Part 1: General principles


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Liquid suppliers dynamic measurement proving systems for volumetric meters - Part 1. General principles ICS 75.180.30 E98 National Standards of People's Republic of China Replacing GB/T 17286.1-1998 Dynamic measurement of liquid hydrocarbons Volumetric metering system Part 1. General principles Part 1. Generalprinciples (ISO 7278-1. 1987, IDT) 2016-12-30 release.2017-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface I Introduction II 1 Scope 1 2 normative reference document 1 3 metrological standard 1 General conditions 5 standard gauge verification system 3 6 online volume tube test system 4 7 Center Verification Station Verification System 4 Standard Flowmeter Verification System

Foreword

GB/T 17286 "liquid hydrocarbon dynamic measurement volume measurement flowmeter verification system" is divided into four parts. - Part 1. General principles; Part 2. Volume tube; Part 3. Pulse insertion technology; - Part 4. Guide for volume tube operator. This part is part 1 of GB/T 17286. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part of the replacement GB/T 17286.1-1998 "Liquid Hydrocarbon Dynamic Measurement Volumetric Flowmeter Verification System Part 1. General in principle". This section and GB/T 17286.1-1998 technical content on the main changes are as follows. --- deleted ISO preface; --- adjust the standard structure, remove the original ISO standard in the suspension section, an increase of part of the secondary title name; --- for the unified format, in 3.1, given the "standard gauge" interpretation; - the term "counting agency" appears on 4.6 and later, and is changed to "tolerance modulator"; --- on the 4.9, the original "continuous four times after the test, there is no two consecutive data to achieve the allowable repeatability" To "continuous four times after the test, there is no three consecutive data to achieve the allowable repeatability"; - the titles of chapters 5, 6, 7 and 8 have been modified; --- some of the standard inaccurate, non-standard statements were modified. This part uses the translation method equivalent to the international standard ISO 7278-1. 1987 "Liquid Hydrocarbon Dynamic Measurement Volume Metering Flowmeter Verification System Part 1. General principles ". And this part of the normative reference documents have a corresponding relationship between China's documents are. Statistical control of volumetric metering systems for dynamic measurement of liquid hydrocarbons (ISO 4124..1994, IDT) GB/T 17287-1998 This part of the National Oil and Gas Standardization Technical Committee (SAC/TC355) proposed and centralized. This part of the drafting unit. China National Petroleum Corporation Metrology and Testing Institute. The main drafters of this section. Gao Jun, Liu Xiaoguang, Zhao Chenghai, Chen Hongju, Cao Yang, Sun Baoyuan. This part of the previous version of the standard to replace the release of the situation. --- GB/T 17286.1-1998.

Introduction

GB/T 17286.1-1988 is based on the international standard ISO 7278 "liquid hydrocarbon dynamic measurement volume measurement flow meter verification system" 1 part of the draft, in China's dynamic measurement of liquid hydrocarbons played an important guiding role. In order to adapt to China's oil industry continues to develop The need to promote international trade and exchange, it is necessary to GB/T 17286.1-1988 revised. ISO 7278 on volumetric tubes, standard Measuring device and pulse insertion technology are described in detail. The relevant standards for other types of verification systems will be supplemented as needed. The calibration flowmeter is to determine the relative error of the flowmeter or the flowmeter coefficient. Flow meter coefficient and measured liquid flow, temperature, pressure And viscosity and other factors. The purpose of determining the relative error of the flowmeter is to know whether the flowmeter is operating within the specified or permissible error range; The coefficient is used to correct the flowmeter indication value. Dynamic measurement of liquid hydrocarbons Volumetric metering system Part 1. General principles

1 Scope

This part of GB/T 17286 establishes the general principles to be followed in the volumetric flowmeter verification system and is applicable to liquid hydrocarbon dynamics measuring.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. ISO 4124 Liquid Hydrocarbons Dynamic Measurement Volumetric Metering System Statistical Control (Liquidhydrocarbons-Dynamicmeas- urement-statisticalcontrolofvolumetricmeteringsystems)

3 metrological standard

3.1 The type of the standard The type of standard is divided into. a) standard gauge. According to the specified structure, made of metal (stainless steel, carbon steel, etc.), with a certain volume, can be used as capacity Value of the measurement instrument. b) volume tube. Including two-way volumetric tubes and one-way volumetric tubes, and 6.7 small volume tubes for special applications. c) Standard flowmeter. A flowmeter as a transfer standard is called a standard flowmeter. The standard flowmeter should be close to the actual operating conditions After passing the test, the working flow meter is verified by the method of volume comparison. This method may generate additional errors. 3.2 standard set The standard can be located in the measurement station (fixed or active), the flow meter on-line liquid test can also be located in the center of the test Station, on the flow meter for off-line verification. 3.3 Minimum number of pulses In order to control the maximum error of the counting system within ± 0.01% of the test, each test run once, the flow meter should be issued at least 10000 A pulse. If pulse insertion is used, the number of pulses can be reduced and allows the use of a flow meter with a smaller pulse per unit volume or Small volume of the measurement standard.

4 general conditions

4.1 verification requirements In the actual conditions of the pressure and temperature conditions, with the measured liquid according to the expected, or the provisions, or both agreed flow, the flow meter into
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17286.1-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17286.1-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17286.1-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17286.1-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 17286.1-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 17286.1-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.