GB/T 17006.11-2015 English PDF

US$1079.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17006.11-2015: Evaluation and routine testing in medical imaging departments -- Part 2-6: Constancy tests -- Imaging performance of computed tomography X-ray equipment
Status: Obsolete
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 17006.11-20151079 Add to Cart 5 days Evaluation and routine testing in medical imaging departments -- Part 2-6: Constancy tests -- Imaging performance of computed tomography X-ray equipment Obsolete

Similar standards

GB/T 13797   GB/T 20013.3   GB 9706.5   GB/T 19042.6   GB/T 19042.5   

Basic data

Standard ID: GB/T 17006.11-2015 (GB/T17006.11-2015)
Description (Translated English): Evaluation and routine testing in medical imaging departments -- Part 2-6: Constancy tests -- Imaging performance of computed tomography X-ray equipment
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: C43
Classification of International Standard: 11.040.50
Word Count Estimation: 27,290
Date of Issue: 2015-12-10
Date of Implementation: 2016-09-01
Older Standard (superseded by this standard): GB/T 17006-1997
Quoted Standard: IEC 60788-2004; GB/T 19042.5-2006; GB 9706.18-2006
Adopted Standard: IEC 61223-2-6-2006, IDT
Regulation (derived from): National Standard Announcement 2015 No.38
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard applies to components that affect image quality, patient dose and positioning of the CT scanning device. This standard: - defines the presentation CT scanning device on the basic parameters of image quality, patient dose and positioning performance; these parameters to be measured, see 4.5; - a detailed description of the methods of measurement of these basic parameters; - providing an evaluation measure the standard deviation of the reference value and compliance data used for random file specified parameters.

GB/T 17006.11-2015: Evaluation and routine testing in medical imaging departments -- Part 2-6: Constancy tests -- Imaging performance of computed tomography X-ray equipment


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Evaluation and routine testing in medical imaging departments - Part 2-6. Constancy tests - Imaging performance of computed tomography X-ray equipment ICS 11.040.50 C43 National Standards of People's Republic of China Replacing GB/T 17006-1997 Evaluation of medical imaging departments and routine testing Part 2-6. X-ray computed tomography apparatus Imaging performance stability test Part 2-6. Constancytests-Imagingperformanceofcomputedtomography X-rayequipment (IEC 61223-2-6.2006, IDT) Issued on. 2016-09-01 2015-12-10 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 5 General Stability Test 5 4.1 Pretreatment 4.2 General Conditions on the test procedure 5 4.3 Establishment of reference values \u200b\u200b6 4.4 equipment, instruments to identify and test conditions 6 Range 4.5 stability test 6 4.6 Test apparatus includes a phantom and test devices 7 Frequency stability test 4.7 7 Test Method 5 CT scanning apparatus 7 7 5.1 Positioning stent patients 5.2 patient positioning accuracy 8 5.3 layer slice thickness 10 5.4 dose 11 5.5 noise, uniformity, and the average value of 12 CT 5.6 spatial resolution 13 Measures Appendix A (informative) adopted guidelines 14 Alternative test methods in Appendix B (informative) spatial resolution of 16 Layer thickness slice Annex C (informative) helical scan 18 Annex D (informative) low contrast resolution visual 19 References 20 Index 22

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 17006-1997 "evaluation in medical imaging departments and routine testing - Part 2-6. X-ray computed Tomography equipment Stability Test. " The standards are compared with the GB/T 17006-1997 main changes as follows. --- The number of chapters has been adjusted; --- On the "program" has been modified and added a few details of the note; --- On the part of the definition has been modified; --- Increases the volume of CT concepts and requirements; --- On the part of the standardization of terminology translation made; --- The term "CT operating state" to "CT operating conditions." This standard is equivalent to using the International Electrotechnical Commission IEC 61223-2-6.2006 "evaluation of medical imaging departments and routine testing 2-6 Section. X-ray computed tomography imaging equipment performance stability test. " Correspondence between the consistency of the standards of international documents and normative references of the following documents. --- GB 9706.18-2006 Medical electrical equipment - Part 2. X-ray computer tomography equipment requirements for the safety (IEC 60601-2-44.2002, IDT); --- GB/T 19042.5-2006 medical imaging departments - Evaluation and routine testing - Part 3-5. X-ray computed tomography camera Movies imaging equipment performance acceptance test (IEC 61223-3-5.2004, IDT). Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This standard was proposed by the State Food and Drug Administration. This standard by the National Technical Committee of Standardization for medical electrical equipment and medical X-ray appliances Technical Committee (SAC/TC10/SC1) Centralized. This standard was drafted. Liaoning Provincial Medical Device Testing, China Quality Certification Center sub-centers in Shenyang, Shanghai Siemens medical instruments have Limited. The main drafters of this standard. Wang Jianjun, Wang Yong, Lu Zhi, Liu Jingbo, Houyao Fang Qu Yan, He Yuhua. This standard replaces the standards previously issued as follows. --- GB/T 17006-1997. Evaluation of medical imaging departments and routine testing Part 2-6. X-ray computed tomography apparatus Imaging performance stability test

1 Scope

This standard is in the X-ray computed tomography apparatus (hereinafter referred to as CT scanning device) provide guidance on stability testing. This standard applies to components that affect image quality, patient dose and positioning of the CT scanning device. This standard. --- Define the basic parameters of the CT scanner statements regarding image quality, patient dose and positioning performance; see these parameters to be measured 4.5; --- Detailed description of these measurements basic parameters; --- Providing the evaluation of measurement data parameters for random document regulatory compliance used by the standard deviation of the reference value and. These methods rely on non-invasive measurements, using appropriate test equipment, by testing to ensure that the functional performance of equipment in line with the establishment of a quasi Then, or be able to change the early identification of equipment components characteristics. Purpose is to test about image quality, patient dose and patient positioning specification compliance. This standard does not relate to. --- Mechanical and electrical safety; --- Mechanical, electrical and software performance, unless they are elements of the implementation of the stability tests, and directly affect image quality, patient Dose and positioning.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. IEC 60788.2004 Medical electrical equipment defined in the glossary (Medicalelectricalequipment-Glossaryof definedterms) IEC 61223-3-5.2004 Evaluation and routine medical imaging departments - Part 3-5 test. X-ray computed tomography apparatus Imaging performance acceptance test (Evaluationandroutinetestinginmedicalimagingdepartments-Part 3-5. Accept- ancetests-ImagingperformancesofcomputedtomographyX-rayequipment) IEC 60601-2-44.2002 Medical electrical equipment - Part 2-44. X-ray computer tomography equipment requirements for the safety (Medicalelectricalequipment-Part 2-44. ParticularrequirementsforthesafetyofX-rayequipment forcomputedtomography)

3 Terms and Definitions

IEC 60788.2004 and the following definition of terms and definitions apply to this document. Note 1. The standard term used in the index definition is given in this standard. Note 2. In this standard, the small print of the 5th term blackbody expressed in GB/T 17006.1 or IEC 60788 has been defined it.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17006.11-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17006.11-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17006.11-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17006.11-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.