Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 16886.6-2022 PDF English

US$440.00 · In stock · Download in 9 seconds
GB/T 16886.6-2022: Biological evaluation of medical devices - Part 6: Tests for local effects after implantation
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 16886.6: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 16886.6-2022440 Add to Cart Auto, 9 seconds. Biological evaluation of medical devices - Part 6: Tests for local effects after implantation Valid
GB/T 16886.6-2015175 Add to Cart Auto, 9 seconds. Biological evaluation of medical devices -- Part 6: Tests for local effects after implantation Obsolete
GB/T 16886.6-1997519 Add to Cart 3 days Biological evaluation of medical devices. Part 6: Tests for local effects after implantation Obsolete

Similar standards

GB/T 16886.4   GB/T 16886.5   GB/T 16886.7   GB/T 16886.10   

GB/T 16886.6-2022: Biological evaluation of medical devices - Part 6: Tests for local effects after implantation


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT16886.6-2022
NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.100.20 CCS C 30 GB/T 16886.6-2022 / ISO 10993-6.2016 Replacing GB/T 16886.6-2015 Biological evaluation of medical devices - Part 6.Tests for local effects after implantation (ISO 10993-6.2016, IDT) Issued on. APRIL 15, 2022 Implemented on. MAY 01, 2023 Issued by. State Administration for Market Regulation; Standardization Administration of the PRC.

Table of Contents

Foreword... 3 Introduction... 5 1 Scope... 8 2 Normative references... 9 3 Terms and definitions... 9 4 Common provisions for implantation test methods... 10 5 Test methods, general aspects... 12 6 Test report... 20 Annex A (Normative) Test methods for implantation in subcutaneous tissue... 22 Annex B (Normative) Test method for implantation in muscle... 25 Annex C (Normative) Test method for implantation in bone... 27 Annex D (Normative) Test method for implantation in brain tissue... 30 Annex E (Informative) Examples of evaluation of local biological effects after implantation... 36 Bibliography... 39

Foreword

This document is drafted in accordance with GB/T 1.1-2020 "Directives for standardization - Part 1.Rules for the structure and drafting of standardizing documents". The document is Part 6 of GB/T 16886 "Biological evaluation of medical devices". GB/T 16886 has issued the following parts. - Part 1.Evaluation and testing within a risk management process; - Part 16.Toxicokinetic study design for degradation products and leachables; - Part 17.Establishment of allowable limits for leachable substances; - Part 18.Chemical characterization of materials; - Part 19.Physico-chemical, morphological and topographical characterization of materials; - Part 20.Principles and methods for immunotoxicology testing of medical devices. This document replaces GB/T 16886.6-2015 "Biological evaluation of medical devices - Part 6.Tests for local effects after implantation". Compared with GB/T 16886.6-2015, in addition to editorial changes, the main technical changes are as follows. a) Add guidance on biological evaluation of absorbable medical devices (see 5.1.2, 5.3.3, 5.3.4, 6.6); b) Add "Test method for implantation in brain tissue" (see Annex D). This document is identical to ISO 10993-6.2016 "Biological evaluation of medical devices - Part 6.Tests for local effects after implantation". Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing authority of this document shall not be held responsible for identifying any or all such patent rights. This document was proposed by National Medical Products Administration. This document shall be under the jurisdiction of National Technical Committee 248 on Biological Evaluation of Medical Devices of Standardization Administration of China (SAC/TC 248). Drafting organizations of this document. Shandong Quality Inspection Center for Medical Devices, Shandong University. Main drafters of this document. Liu Jia, Sun Likui, Liu Shangming, Zhu Fuyu, Liu Zhaohua, Yu Yang. The previous releases of this document and the documents it replaces are as follows. - It was first issued in 1997 as GB/T 16886.6-1997 and first revised in 2015; - This is the second revision.

1 Scope

This document specifies test methods for the assessment of the local effects after implantation of biomaterials intended for use in medical devices. This document applies to materials that are

2 Normative references

The contents of the following documents, through normative references in this text, constitute indispensable provisions of this document. Among them, for dated references, only the edition corresponding to that date applies to this document. For undated references, the latest edition (including all amendments) applies to this document. ISO 10993-1 Biological evaluation of medical devices - Part 1.Evaluation and testing within a risk management process

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 10993-1, ISO 10993-2, ISO 10993-12, ISO 10993-16 and the following apply. Action of a non-endogenous (foreign) material or substance, or its decomposition products passing through or being assimilated by cells and/or tissue step by step.

4 Common provisions for implantation test methods

For devices comprising/composed of two or more different materials, the test articles should be of similar composition or multiple implants may be needed, e.g. if a device is made of HDPE and titanium then the test article should be made of HDPE and titanium.

5 Test methods, general aspects

Each implant site shall be examined for alterations of the normal structure. This should include assessment of the regional draining lymph nodes. Use of a lens with low magnification is recommended. The scoring system used for the histological evaluation shall take into account the extent of the area affected, either quantitatively (e.g. in micrometres) orsemiquantitatively (see Annex E).

6 Test report

The report shall include a comparative evaluation of the local effects after implantation in terms of the biological responses to test and control materials. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 16886.6-2022 be delivered?Answer: The full copy PDF of English version of GB/T 16886.6-2022 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 16886.6-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 16886.6-2022_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 16886.6-2022 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB/T 16886.6-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16886.6-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB/T 16886.6-2022?

A step-by-step guide to download PDF of GB/T 16886.6-2022_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 16886.6-2022".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9