GB/T 16886.3-2019 PDF EnglishUS$460.00 · In stock · Download in 9 seconds
GB/T 16886.3-2019: Biological evaluation of medical devices -- Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 16886.3: Historical versions
Similar standardsGB/T 16886.3-2019: Biological evaluation of medical devices -- Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT16886.3-2019 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.100 C 30 GB/T 16886.3-2019 / ISO 10993-3.2014 Replacing GB/T 16886.3-2008 Biological evaluation of medical devices - Part 3.Tests for genotoxicity, carcinogenicity and reproductive toxicity (ISO 10993-3.2014, IDT) Issued on. JUNE 04, 2019 Implemented on. JANUARY 01, 2020 Issued by. State Administration for Market Regulation; Standardization Administration of the PRC. Table of ContentsForeword... 3 Introduction... 6 1 Scope... 7 2 Normative references... 7 3 Terms and definitions... 8 4 Requirements for test strategies... 9 5 Genotoxicity tests... 11 6 Carcinogenicity tests... 16 7 Reproductive and developmental toxicity tests... 19 8 Test report... 22 Annex A (Informative) Guidance on selecting an appropriate sample preparation procedure in genotoxicity testing... 23 Annex B (Informative) Flowchart for follow-up evaluation... 34 Annex C (Informative) Rationale of test systems... 35 Annex D (Informative) Cell transformation test systems... 37 Annex E (Normative) Considerations for carcinogenicity studies performed as implantation studies... 39 Annex F (Informative) In vitro tests for embryo toxicity... 41 Bibliography... 43ForewordGB/T 16886 "Biological evaluation of medical devices" consists of the following parts. - Part 1.Evaluation and testing within a risk management process; - Part 2.Animal welfare requirements; - Part 3.Tests for genotoxicity, carcinogenicity and reproductive toxicity; - Part 4.Selection of tests for interactions with blood; - Part 5.Tests for in vitro cytotoxicity; - Part 6.Tests for local effects after implantation; - Part 7.Ethylene oxide sterilization residuals; - Part 9.Framework for identification and quantification of potential degradation products; - Part 10.Tests for irritation and skin sensitization; - Part 11.Tests for systemic toxicity; - Part 12.Sample preparation and reference materials; - Part 13.Identification and quantification of degradation products from polymeric medical devices; - Part 14.Identification and quantification of degradation products from ceramics; - Part 15.Identification and quantification of degradation products from metals and alloys; - Part 16.Toxicokinetic study design for degradation products and leachables; - Part 17.Establishment of allowable limits for leachable substances; - Part 18.Chemical characterization of materials; - Part 19.Physico-chemical, morphological and topographical characterization of materials; - Part 20.Principles and methods for immunotoxicology testing of medical devices. This Part is Part 3 of GB/T 16886. This Part is drafted in accordance with the rules given in GB/T 1.1-2009. This Part replaces GB/T 16886.3-2008 "Biological evaluation of medical devices - Part 3.Tests for genotoxicity carcinogenicity and reproductive toxicity". Compared with GB/T 16886.3-2008, in addition to editorial changes, the main technical changes are as follows. - CHANGE the test strategy by adding in vivo test and follow-up evaluation; - ADD Annex A "Guidance on selecting an appropriate sample preparation procedure in genotoxicity testing"; - ADD further in vitro and in vivo tests, to assess the genotoxic potential of medical devices; - ADD Annex B "Flowchart for follow-up evaluation"; - CHANGE the former Annex C to Annex E "Considerations for carcinogenicity studies performed as implantation studies" and develop specifications; - ADD Annex F "In vitro tests for embryo toxicity". This Part, using translation method, is identical to ISO 10993-3.2014 "Biological evaluation of medical devices - Part 3.Tests for genotoxicity, carcinogenicity and reproductive toxicity". China’s documents which have a consistent correspondence with the international documents normatively referenced in this Part are as follows. - GB/T 16886.1-2011 Biological evaluation of medical devices - Part 1. Evaluation and testing within a risk management process (ISO 10993- 1.2009, IDT) - GB/T 16886.2-2011 Biological evaluation of medical devices - Part 2. Animal welfare requirements (ISO 10993-2.2006, IDT) - GB/T 16886.6-2015 Biological evaluation of medical devices - Part 6.Tests for local effects after implantation (ISO 10993-6.2007, IDT) - GB/T 16886.12-2017 Biological evaluation of medical devices - Part 12. Sample preparation and reference materials (ISO 10993-12.2012, IDT) - GB/T 16886.18-2011 Biological evaluation of medical devices - Part 18. Chemical characterization of materials (ISO 10993-18.2005) Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing authority of this document shall not be held responsible for identifying any or all such patent rights. This Part was proposed by National Medical Products Administration. This Part shall be under the jurisdiction of National Technical Committee 248 on Biological Evaluation of Medical Devices of Standardization Administration of China (SAC/TC 248). Drafting organizations of this Part. Shandong Quality Inspection Center for Medical Devices, Sichuan University. Main drafters of Part. Hou Li, Sun Xiaoxia, Liang Jie, Yuan Tun, Li Qiu. The previous editions of the standard replaced by this Part were released as follows. - GB/T 16886.3-1997, GB/T 16886.3-2008.1 ScopeThis Part of GB/T 16886 specifies strategies for risk estimation, selection of hazard (source) identification tests and risk management, with respect to the possibility of the following potentially irreversible biological effects arising as a result of exposure to medical devices.2 Normative referencesThe following documents are indispensable for the application of this document. For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document. ISO 10993-1 Biological evaluation of medical devices - Part 1.Evaluation and testing within a risk management process3 Terms and definitionsFor the purposes of this document, the terms and definitions given in ISO 10993-1, ISO 10993-12 and the following apply.4 Requirements for test strategiesTesting may be warranted for additional states of the device such as, wear debris generated from the device or materials that cure in situ (e.g. cements, adhesives and pre-polymer mixtures) unless toxicological risk assessment determines no cause for concern from additional device/material states. For guidance on in situ curing devices see ISO 10993-12.5 Genotoxicity testsUnless the sample can be dissolved in a solvent compatible with the test system, appropriate extraction solvents shall be chosen on the basis of its ability to maximize extraction of the material or medical device to a level at which the concentration of genotoxic residues would be sufficient to produce a positive response in the test system, but without degradation of the device or the test sample.6 Carcinogenicity testsCarcinogenicity testing of genotoxic materials shall be scientifically justified. In most instances for genotoxic materials, a carcinogenic hazard can be presumed and the risk managed accordingly.7 Reproductive and developmental toxicity testsSample preparation shall be in accordance with ISO 10993-12.Whenever possible the medical device shall be tested in a form representative of its final state. Additional testing may be warranted for additional states of the device such as, device or materials that cure in situ (e.g. bone cements, adhesives and pre-polymer mixtures).8 Test reportIf relevant, the test report shall include at least the following details. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 16886.3-2019 be delivered?Answer: The full copy PDF of English version of GB/T 16886.3-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 16886.3-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 16886.3-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 16886.3-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 16886.3-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16886.3-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 16886.3-2019?A step-by-step guide to download PDF of GB/T 16886.3-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 16886.3-2019". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |