GB/T 16881-2008: Coagulation -- Deposition jar test of water
Status: Valid

GB/T 16881: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 16881-2008139 Add to Cart 3 days Coagulation -- Deposition jar test of water Valid
GB/T 16881-1997279 Add to Cart 3 days Coagulation--Flocculation jar test of water Obsolete

Similar standards

GB/T 16632   GB/T 15453   GB/T 14643.1   GB/T 45386.1   GB/T 45131   GB/T 14420   

Basic data

Standard ID: GB/T 16881-2008 (GB/T16881-2008)
Description (Translated English): Coagulation -- Deposition jar test of water
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G76
Classification of International Standard: 71.100.40
Word Count Estimation: 6,683
Date of Issue: 2008-06-04
Date of Implementation: 2008-12-01
Older Standard (superseded by this standard): GB/T 16881-1997
Regulation (derived from): National Standard Approval Announcement 2008 No.9 (Total No.122)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the water coagulation, precipitation test device test cup tests, operating conditions and operating procedures. This standard applies to determine the water coagulation, process parameters precipitation process, including: coagulant, kind of flocculant, usage, pH of the water, temperature, and various pharmaceutical dosage order and so on.

GB/T 16881-2008: Coagulation -- Deposition jar test of water

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Coagulation.Deposition jar test of water ICS 71.100.40 G76 National Standards of People's Republic of China Replacing GB/T 16881-1997 Water coagulation, sedimentation test cup test method Posted 2008-06-04 2008-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard replaces GB/T 16881-1997 "coagulation, flocculation jar test of water." This standard and GB/T 16881-1997 compared to the main changes are as follows. --- The standard name was changed to "water coagulation, sedimentation test cup test method"; --- This standard adds support for high speed gradient (G value) test requirements. The standard proposed by the People's Republic of China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee of Chemical Water Treatment Chemicals Branch (SAC/TC63/SC5) centralized. This standard is drafted by. Guangming Chemical Research and Design Institute, Tongji University, Tianjin Chemical Engineering Research and Design Institute. The main drafters of this standard. Abolished Guoxi Min, Guo Fengxiang, Li Fengting, Bai Ying. This standard was first published in 1997. Water coagulation, sedimentation test cup test method

1 Scope

This standard specifies the water coagulation, sedimentation test sample cup test apparatus, operating conditions and operating procedures. This standard applies to determine the water coagulation, sedimentation process parameters, including. coagulants, flocculants species, the amount of water pH Value, temperature, and various drug dosing sequence and so on.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 605 chemical reagent Chroma General method (GB/T 605-2006ISO 6353-1. 1982, NEQ) GB/T 5750 drinking water standards test GB/T 9724 General rule for determination of pH chemical reagent (GB/T 9724-2007, ISO 6353-1. 1982, NEQ) GB/T 15724.1 laboratory glassware beaker (GB/T 15724.1-1995, ISO 3819. 1985, NEQ)

3 Method summary

Water coagulation, sedimentation cuvette tests include rapid stirring, stirring slowly and still subsidence three steps. Dosing of coagulant, flocculant After rapid stirring rapidly dispersed particles in contact with the water samples, particles started to gather produce micro floc. By slow stirring, into a micro floc Step into contact with each other to grow into larger particles. After the stirring was stopped, the formation of micelle aggregate by gravity settling to the bottom of the container. By measuring water samples after the test turbidity, color, you can determine the coagulant properties.

4 device

Over 4.1 United stirrer Speed can be infinitely adjusted between 20r/min ~ 150r/min. Stirring blades made of lightweight corrosion-resistant material, paddle size 60mm × 40mm × 2mm, a rectangular shape. In front of the base or the inside of the multi-joint stirrer illumination device, it can be observed by Flakes formation. Multi-joint stirrer and paddle sizes, submerged position diagram shown in Figure 1.

1 stirring paddle size and location of the schematic

......
Image