Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 15952-2010 English PDF

US$414.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 15952-2010: Electroacoustics -- Specifications for personal sound exposure meters
Status: Valid

GB/T 15952: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 15952-2010414 Add to Cart 4 days Electroacoustics -- Specifications for personal sound exposure meters Valid
GB/T 15952-1995719 Add to Cart 3 days Specifications for personal sound exposure meters Obsolete

Similar standards

GB/T 14365   GB/T 15173   GB/T 18696.1   GB/T 45305.4   GB/T 16405   GB/T 20243.2   

Basic data

Standard ID: GB/T 15952-2010 (GB/T15952-2010)
Description (Translated English): Electroacoustics -- Specifications for personal sound exposure meters
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: A59
Classification of International Standard: 17.140.50
Word Count Estimation: 21,264
Date of Issue: 2010-12-01
Date of Implementation: 2011-05-01
Older Standard (superseded by this standard): GB/T 15952-1995
Quoted Standard: GB/T 3238-1982; GB/T 3240-1982; GB/T 3785-1983; GB 9254-2008; GB/T 14366-1993; GB/T 15173-1994; GB/T 17181-1997; GB/T 17626.2-2006; GB/T 17626.3-2006; GB/T 17799.1-1999; GB/T 17799.2-2003; GB/T 17799.3-2001; GB/T 21230-2007; IEC 60050-801-1984; IEC 60801-2-1984; IEC 60801-3-1984
Adopted Standard: IEC 61252-2002, IDT
Regulation (derived from): Announcement of Newly Approved National Standards 2010 No. 9 (No. 164 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard provides a level of accuracy of personal sound exposure meter electric, acoustic performance requirements, when the A -weighted sound pressure level range is 80dB ~ 130dB, the nominal frequency range of 63Hz ~ 8kHz, this level of accuracy and compliance GB/T17181 type 2 integrating sound level meter requires considerable. This standard applies to steady-state measurements, intermittent, fluctuating, irregular pulse sound or A-weighted sound exposure of the instrument. In line with the standards specified instrument worn on the body to measure sound exposure. Workplace sound exposure measurements for determination according to GB/T14366 and GB/T21230 occupational noise exposure may be useful.

GB/T 15952-2010: Electroacoustics -- Specifications for personal sound exposure meters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electroacoustics.Specifications for personal sound exposure meters ICS 17.140.50 A59 National Standards of People's Republic of China Replacing GB/T 15952-1995 Electro-acoustics personal sound exposure meters Specification (IEC 61252.2002, IDT) Issued on. 2010-12-01 2011-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 3 General performance requirements 4 5 reference conditions 6 absolute sound sensitivity 4 7 Frequency weighting 4 Linear 8-steady-state signal response of 5 Response nine pairs of short duration signal 6 Response 10 pairs of unipolar pulses 6 11 self-locking overload indicator 6 Environmental sensitivity of 12 pairs of 6 13 7 Instrument Flag 14 User's Guide 7 15 electrostatic and electromagnetic compatibility requirements and test procedures 8 Appendix A (informative) sound exposure and the corresponding normalized 8h average sound level 12 Annex B (informative) personal sound exposure meter test performance test recommendations 13 Annex C (informative) emission limits 16 Functional unit 1 personal sound exposure meter 3 Table 1 applies to the entire personal sound exposure meter performance with respect to the design goal A frequency weighting 1kHz response and tolerance ΔA 5 Table A.1 sound exposure and the corresponding normalized 8h average sound level 12 Table B.1 1kHz minimum steady state signal linear combinations of the target test conditions 13 Table B.2 of the short duration of the signal response of the test conditions 15 Table C.1 measured distance is 10m Class B information technology equipment Radiated disturbance limits 16

Foreword

This standard is identical with IEC 61252.2002 "electro-acoustics personal sound exposure meter specifications" (in English). This standard references the following countries The corresponding standard home contents and IEC 61252.2002 "electro-acoustics personal sound exposure meter specifications" (English Version) Content equivalents. a) GB/T 3238-1982 Acoustics volume level and a reference value (neqISO 1683. 1983); b) GB/T 3240-1982 acoustical measurement commonly used frequency (neqISO 266. 1975); c) GB/T 3785-1983 sound level meter Electricity, Sound Performance and Test Methods (neq IEC 60651. 1979); Evaluation of hearing impairment d) GB/T 14366-1993 Acoustics measurements and noise occupational noise-induced (eqvISO 1999.1990). For ease of use, this standard made the following editorial changes. a) instead of as a decimal by decimal comma ",". ","; b) use the "standard" instead of "this International Standard"; c) Remove the IEC 61252.2002 in the preface, in which the individuals concerned and the sound exposure meters and integrating sound level meter is the difference between the contents of cooperation And this standard the "Introduction"; d) Normative documents according to the introductory phrase of GB/T 1.1-2000 rewritten; e) The IEC 61252. "Definitions" section of the 2002 merger of the two key words, according to GB/T 1.1-2000 requirements rewritten; f) 15.1.2 "Before release of the amendments" is replaced by "Prior to this release." This standard replaces GB/T 15952-1995 "personal sound exposure meters." This standard and GB/T 15952-1995 compared to the main changes are as follows. a) the standard name was changed to "electro-acoustics for personal sound exposure meters norms"; b) "Introduction" section of GB/T 1.1-2000 requirements rewritten; c) Remove the "IEC foreword"; d) "Introduction," added the former "IEC foreword" in relation to personal sound exposure meters and integrating sound level meter difference; e) normative reference list file, add about six electromagnetic compatibility standard and GB/T 21230-2007 (ISO 9612.1997, IDT) and other documents; f) increased "(personal sound exposure meter) reference bearing" terms and definitions; g) Chapter 14 of u) item from the 1995 edition of the u), v) the content of the two merger; h) In Chapter 14, "User's Guide," added the first w) to cc); i) an increase of Chapter 15, "electrostatic and electromagnetic compatibility requirements and test procedures"; j) Added Appendix C "emission limits." This standard Annex A, Annex B and Annex C is informative appendix. The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This standard by the National Standardization Technical Committee electro-acoustics (SAC/TC23) centralized. This standard was drafted. Hengyang Heng Instrument Electric Co., Ltd., China Institute of Metrology, red acoustic equipment factory Jiaxing factory, measurement Shenzhen Quality Inspection Institute. The main drafters of this standard. Liu Xiangheng, Chen Jianlin, Tan Teng Shu Guohua, Zhang Guoqing. This standard was first released in December 1995, this is the first revision.

Introduction

The intent of this standard, personal sound exposure meter is used to measure sound exposure, the instantaneous A-weighted sound pressure frequency square time integral. Its work As is the principle according to GB/T 17181 measured sound exposure level is based, that is, "and other energy exchange rate", the integration time constant sound level doubles (Or halved) will sound exposure doubled (or halved). Similarly, the integration time constant of the input sound level increases (or decreases) 3dB, the sound exposure Doubled (or halved). Noise dosimeter is usually designed to indicate the percentage of statutory limit noise dose. Limit its definition of national regulations vary, and will change. In order to facilitate international comparison with the conventional recording sound exposure value represented by this standard specifies a quadratic Pa hour indication sound storm Lu instruments. As long as the manufacturer specified will be shown value is converted to quadratic Pa hour method, it allows outside Pa hours quadratic Other Unit indication sound exposure, for example, display fraction or percentage of the "dose" --- the provisions to sound quadratic Pa units of hours of exposure. Personal sound exposure meter main application is to measure human exposure to sound near the head, for example, according to GB/T 14366 and other standards to evaluate possible hearing Power loss. Personal sound exposure meter microphone can be worn on the shoulder, collar, or other parts of your ear. For a number of specific cases, For example, in the factory, the incident angle of the sound will be great changes during the working day, the sound of the instrument worn on the body indicated may be exposed and personnel Measurements at different time of absence. When the sound when the body is not present estimates of exposure, it should consider wearing affect the body's personal sound exposure meter. The standard for personal sound exposure meter standard and GB/T 17181-1997 comparable specification for integrating sound level meter in a practical range Consistent. Compared with the 1997 release of GB/T 17181 in the specification, there are four main differences. a) measures and displays sound exposure instead of the equivalent continuous sound pressure level or frequency weighted sound exposure level; b) the accuracy of short duration signal points and the square with the provisions of sound exposure duration 1ms ~ 10ms of constant amplitude of 4kHz Repeat measurement burst tone sequence, rather than the measurement of duration ranging from single 4kHz horn tone bursts of 1ms ~ 1s In response, each of the burst tone is accompanied by its own continuous-phase, low 4kHz background signal; c) personal sound exposure meter specifications include positive and negative unipolar acoustic impulse response difference between the exposure limit values are shown; d) does not require the wearing of the human body sound exposure meter used microphone directivity requirements. Electro-acoustics personal sound exposure meters Specification

1 Scope

1.1 standard provides a level of accuracy of the personal sound exposure meter electric, acoustic performance requirements, when A-weighted sound pressure level range is 80dB ~ 130dB, the nominal frequency range of 63Hz ~ 8kHz, this level of accuracy and compliance with GB/T 17181 requirements for Type 2 Points Sound Level Meter fairly. 1.2 This standard applies to the measurement of steady, intermittent, fluctuating, A-weighted sound or irregular pulse sound exposure instrument. Comply with this Standard Specification for instrument worn on the body measurement specified sound exposure. Measurement of workplace sound exposure, according to GB/T 14366 and GB/T 21230 Determination of occupational noise exposure may be useful. 1.3 sound exposure in a given position, by instantaneous frequency-weighted sound pressure squared integrated over time, it included a sound pressure of both its duration Physical measure. 1.4 Instrument performance deviates from a predetermined tolerance level on behalf of a specific instrument performance design goals. Within a specified range of environmental conditions, requirements Within this standard tolerance of personal sound exposure meter work.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 3238-1982 Acoustics volume level and a reference value (neqISO 1683. 1983) GB/T 3240-1982 acoustical measurement commonly used frequency (neqISO 266. 1975) GB/T 3785-1983 sound level meter Electricity, Sound Performance and Test Methods (neq IEC 60651. 1979) GB radio disturbance characteristics - Limits and methods of measurement 9254-2008 information technology equipment (CISPR22.2006, IDT) GB/T 14366-1993 hearing impairment evaluation of occupational noise and acoustic noise caused by (eqvISO 1999.1990) GB/T 15173-1994 acoustic calibrator (eqvIEC 60942. 1988) GB/T 17181-1997 integrated average sound level (idtIEC 60804. 1985) GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2.2001, IDT) GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test (IEC 61000-4- 3.2002, IDT) GB/T 17799.1-1999 Electromagnetic compatibility - Generic standards for residential, commercial and light industrial environment - Immunity (IdtIEC 61000-6-1.1997) GB/T 17799.2-2003 Electromagnetic compatibility - Generic standards - Immunity for industrial environments (IEC 61000-6-2.1999, IDT) GB/T 17799.3-2001 Electromagnetic compatibility - Generic standards for residential, commercial and light industrial environments Emission standard (IdtCISPR61000-6-3.1996) GB/T 21230-2007 Acoustics working environment measurement and evaluation guide of the noise exposure (ISO 9612.1997, IDT) IEC 60050 (801). Enhanced Edition 1984 International Electrotechnical Vocabulary Chapter 801, acoustics and electro-acoustics IEC 60801-2. 1984 Industrial process measurement and control equipment Electromagnetic compatibility - Part 2. Electrostatic discharge requirements IEC 60801-3. 1984 Electromagnetic industrial process measurement and control equipment compatibility - Part 3. Radio frequency electromagnetic field requirements
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15952-2010_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15952-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15952-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15952-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15952-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15952-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.