GB/T 15166.4-2021: High-voltage alternating-current fuses - Part 4: Fuse for exteanal protection of shunt capacitors
Status: Valid

GB/T 15166.4: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 15166.4-2021329 Add to Cart 4 days High-voltage alternating-current fuses - Part 4: Fuse for exteanal protection of shunt capacitors Valid
GB/T 15166.4-2008599 Add to Cart 3 days High-voltage alternating-current fuses -- Part 4: Fuses for external protection of shunt power capacitors Obsolete
GB/T 15166.4-1994199 Add to Cart 2 days Alternating-current high-voltage fuses. General test method Obsolete

Similar standards

GB/T 3906   GB/T 11022   GB/T 30092   GB/Z 15166.8   GB/T 15166.3   GB/T 15166.6   

Basic data

Standard ID: GB/T 15166.4-2021 (GB/T15166.4-2021)
Description (Translated English): High-voltage alternating-current fuses - Part 4: Fuse for exteanal protection of shunt capacitors
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K43
Word Count Estimation: 17,184
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 15166.4-2021: High-voltage alternating-current fuses - Part 4: Fuse for exteanal protection of shunt capacitors


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
High-voltage alternating-current fuses -- Part 4: Fuse for exteanal protection of shunt capacitors ICS 29:120:50 CCSK43 National Standards of People's Republic of China Replacing GB/T 15166:4-2008 High Voltage AC Fuses Part 4: Shunt capacitor external protection fuse (IEC 60549:2013, High-voltagefusesforexternalprotectionof Published on 2021-12-31 2022-07-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface I Introduction III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Normal and special conditions of use2 5 Performance Requirements 3 5:1 General requirements 3 5:2 Breaking Requirements 3 6 Type test 3 6:1 Overview 3 6:2 Test practice 4 6:3 Power frequency inductive current breaking test 4 6:4 Power frequency capacitive current interruption test 4 6:5 Capacitor discharge breaking test 8 6:6 Standard status for breaking test performance 10 7 Information provided to users10 8 Application Information 10 8:1 Operating voltage 10 8:2 Rated voltage 11 8:3 Rated current 11 Reference 12

foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted: This document is part 4 of GB/T 15166 "High Voltage AC Fuse": GB/T 15166 has released the following parts: --- Part 1: Terminology; --- Part 2: Current limiting fuses; --- Part 3: Jet fuses; --- Part 4: Fuse for external protection of parallel capacitors; --- Part 5: Guidelines for the selection of fuses for high-voltage fuses in motor circuits; --- Part 6: Guidelines for the selection of fuses for high-voltage fuses in transformer circuits: This document replaces GB/T 15166:4-2008 "High Voltage AC Fuses Part 4: Fuse for External Protection of Parallel Capacitors", and Compared with GB/T 15166:4-2008, in addition to structural adjustment and editorial changes, the main technical changes are as follows: ---Added fuses for external protection of capacitors that meet the provisions of this document and GB/T 15166:2 or GB/T 15166:3 description (see Chapter 1); --- Delete the description of fuse classification (see 3:2 of the:2008 edition); --- Deleted "rated value" (see Chapter 4 of the:2008 edition); --- Deleted the two chapters of "Design, Structure and Performance" (see Chapter 5 of the:2008 edition); ---Added "performance requirements", only for "rated maximum capacitive breaking current" and "rated discharge energy of capacitors withstanding fuse": out requirements (see Chapter 5); --- Deleted the insulation test (see 6:4 of the:2008 edition); --- Delete the temperature rise test (see 6:5 of the:2008 edition); --- Delete the time-current characteristic test (see 6:7 of the:2008 edition); --- Delete the withstand discharge test (see 6:8 of the:2008 edition); --- Changed the breaking times of small capacitive current from 3 times to 2 times (see 6:4:5, 6:6:2:2 of the:2008 edition); --- Deleted "factory test" (see Chapter 7 of the:2008 edition); --- Deleted "Acceptance Test" (see Chapter 8 of the:2008 edition); --- Deleted "transportation and storage" (see Chapter 10 of the:2008 edition); --- Deleted "Security" (see Chapter 11 of the:2008 edition): This document is revised and adopted IEC 60549:2013 "High-voltage fuses for external protection of parallel capacitors": The structure of this document has changed from IEC 60549:2013: Due to the addition of Chapter 4, the numbering of subsequent chapters has been postponed: The technical differences between this document and IEC 60549:2013 and their reasons are as follows: --- Regarding normative reference documents, this document has made adjustments with technical differences to adapt to the technical conditions of our country and the circumstances of the adjustment: The situation is reflected in Chapter 2 "Normative References", and the specific adjustments are as follows: ● Replacing IEC 60871-1 with GB/T 11024-2019, which has been modified to adopt international standards; ● Replacing IEC 60282-1:2009 with GB/T 15166:2-2008, which adopts the international standard; ● Replacing IEC 60282-2 with GB/T 15166:3 which adopts the international standard; ● Added reference to GB/T 15166:1-2019: --- Adjust the applicable capacitors from the text to Note, and make the fuses in 4:1 of IEC 60549:2013 meet the requirements On the basis of GB/T 15133:2 or GB/T 15166:3, the descriptions that meet the requirements of this document are put into the scope (see Chapter 1, Chapter 1 of IEC 60549:2013); --- Terms and definitions The introduction has added reference standards (see Chapter 3); --- Change the term "capacitor rated discharge energy" to "capacitor rated discharge energy withstand by fuse" (see 3:10, IEC 60549: 3:10 of:2013); --- Added normal and special conditions of use (see Chapter 4); --- Added Figure 3 capacitor discharge breaking test wiring diagram (see 6:5:2): The following editorial changes have been made to this document: --- In order to be consistent with my country's technical standard system, the standard name is changed to "High Voltage AC Fuses Part 4: External Protection of Parallel Capacitors" Protective fuse"; --- Adjusted references: Please note that some content of this document may be patented: The issuing agency of this document assumes no responsibility for identifying patents: This document is proposed by China Electrical Equipment Industry Association: This document is under the jurisdiction of the National Fuse Standardization Technical Committee (SAC/TC340): This document is drafted by: Xi'an High Voltage Electric Apparatus Research Institute Co:, Ltd:, Risheng Group Co:, Ltd:, Xi'an Jiaotong University, State Grid Hebei Provincial Electric Power Co:, Ltd: Electric Power Research Institute, Cooper Electronic Technology (Shanghai) Co:, Ltd:, China Electric Power Research Institute Co:, Ltd:, State Grid Electric Power Research Institute of Liaoning Electric Power Co:, Ltd:, Electric Power Research Institute of State Grid Zhejiang Electric Power Co:, Ltd:, State Grid Shaanxi Electric Power Company Electric Power Research Institute, Shanghai Electric Transmission and Distribution Test Center Co:, Ltd:, Schneider Electric (China) Co:, Ltd:, Shanghai Dikang Power Equipment Co:, Ltd:, Shandong Taikai Intelligent Power Distribution Co:, Ltd:, Suzhou Electrical Apparatus Research Institute Co:, Ltd:, Zhejiang Bada Electronic Instrument Co:, Ltd: Shitong Electric Branch, Ningbo Shunli High Voltage Switch Technology Co:, Ltd:, Eaton Electric Co:, Ltd:, Jiangdong Hardware Equipment Co:, Ltd:, Chint Electric Co:, Ltd:, Dekai Quality Certification (Shanghai) Co:, Ltd:, Zhejiang Minyuan High Voltage Electric Co:, Ltd: The main drafters of this document: Zhang Zixiao, Tian Enwen, Shi Weijian, Sun Mei, Feng Wujun, Liu Zhiyuan, Xing Na, Gu Chaomin, Sun Ming, Pang Xianhai, Xie Ruitao, Feng Ying, Fan Guangwei, Wang Feiming, Zhao Qingbin, Xie Cheng, Shi Hongwei, Yang Ren, Kong Xiangjun, Qiu Weifeng, Lei Xiaoqiang, Tan Yan, Ren Xiaodong, Yang Yingjie, Ye Shuxin, Li Xiaodong, Hu Guangfu, Chen Hongfei, Le Sanxiang, Cui Xudong, Chen Wen, Dai Haoze: The previous versions of this document and its superseded documents are as follows: ---First published in:1994 as GB/T 15166:4-1994, first revised in:2008; ---This is the second revision:

Introduction

High-voltage AC fuse products are widely used in power transmission and distribution systems with a nominal voltage of 3kV and above in my country, as well as in factories, mines, and small residents: In the area, it is used as a protection device for lines and equipment such as motors, transformers, and fuses: In this regard, my country has established a support GB/T 15166 series national standard system for current fuse products: GB/T 15166 aims to establish suitable for high-voltage AC fuse design, Ratings, tests and selection criteria for special applications are to be composed of 7 parts: --- Part 1: Terminology: The purpose is to provide common terminology for standards within the system: --- Part 2: Current limiting fuses: The purpose is to put forward specification requirements for high-voltage AC current-limiting fuses: --- Part 3: Jet fuses: The purpose is to put forward specification requirements for high-voltage AC jet fuses: --- Part 4: Fuse for external protection of parallel capacitors: The purpose is to provide the special work of fuses for external protection of parallel capacitors: specific additional requirements: --- Part 5: Guidelines for the selection of high-voltage fuses for motor circuits: The purpose is to protect the motor circuit The special case of fuses puts forward special additional requirements: --- Part 6: Guidelines for the selection of fuses for high-voltage fuses in transformer circuits: The purpose is to protect the transformer circuit with The special case of fuses puts forward special additional requirements: --- Part 7: Guidelines and application guidelines for high-voltage fuses: The purpose is to provide guidance for the selection of fuses under different operating conditions: High Voltage AC Fuses Part 4: Shunt capacitor external protection fuse

1 Scope

This document specifies the terms and definitions, normal and special use conditions, performance requirements, type tests of fuses for external protection of shunt capacitors inspection requirements: This document applies to external fuses used in high-voltage capacitors complying with GB/T 11024:1-2019: Note: GB/T 11024:1-2019 is applicable to both the capacitor unit used and the capacitor bank used, especially in the AC power system For power factor compensation, it is also suitable for capacitors in power filter circuits: This document covers the internal faults used to eliminate a single capacitor unit to allow the rest of the capacitor bank to be connected to this unit fuses that continue to operate (unit fuses); and fuses that eliminate the failure of the entire capacitor bank and isolate it from the system (line blown device): These fuses meet the requirements of this document on the basis of GB/T 15166:2-2008 or GB/T 15166:3: This document does not cover devices that do not need to interrupt capacitive currents [such as no capacitive currents will flow, or as other devices (to interrupt capacitive currents) The "backup" use (breaking large inductive currents)] fuses, see GB/T 15166:2-2008 or GB/T 15166:3 for their requirements: In this document, the terms "capacitive current" and "inductive current" are used on the one hand to denote leading and lagging power factor test currents, respectively; On the one hand, it means that the line mainly contains capacitive or inductive components: On occasions that do not necessarily require special emphasis on different meanings, this paper The term "capacitor unit" and "capacitor bank" in the article may be replaced by the word "capacitor":

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document: GB/T 11024:1-2019 Shunt capacitors for AC power systems with nominal voltages above 1000V - Part 1: General (IEC 60871-1:2014, MOD) GB/T 15166:1-2019 High Voltage AC Fuses Part 1: Terminology (IEC 60050-441:1984, MOD) GB/T 15166:2-2008 High Voltage AC Fuses Part 2: Current-Limiting Fuses (IEC 60282-1:2005, MOD) GB/T 15166:3 High Voltage AC Fuses Part 3: Jet Fuses (GB/T 15166:3-2008, IEC 60282-2: 1995, MOD)

3 Terms and Definitions

The terms and definitions defined in GB/T 15166:1-2019 and the following terms and definitions apply to this document: 3:1 (capacitor) element A component consisting of a dielectric and electrodes separated by it: [Source: GB/T 2900:16-1996, 3:1:1]
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15166.4-2021_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15166.4-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15166.4-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15166.4-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15166.4-2021?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15166.4-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.