Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 15092.101-2020 English PDF

US$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 15092.101-2020: Switches for appliances - Part 1-1: Requirements for mechanical switches
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 15092.101-2020259 Add to Cart 3 days Switches for appliances - Part 1-1: Requirements for mechanical switches Valid

Similar standards

GB/T 4343.2   GB/T 3883.311   GB/T 3787   GB/T 15092.2   GB/T 15092.3   GB/T 15092.4   

Basic data

Standard ID: GB/T 15092.101-2020 (GB/T15092.101-2020)
Description (Translated English): Switches for appliances - Part 1-1: Requirements for mechanical switches
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K64
Classification of International Standard: 29.120.40
Word Count Estimation: 14,115
Date of Issue: 2020-12-14
Date of Implementation: 2021-07-01
Quoted Standard: GB/T 15092.1-2020
Adopted Standard: IEC 61058-1-1-2016, MOD
Regulation (derived from): National Standard Announcement No. 28 of 2020
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration
Summary: This standard applies to mechanical switch appliances and should be used in conjunction with GB/T 15092.1-2020.

GB/T 15092.101-2020: Switches for appliances - Part 1-1: Requirements for mechanical switches

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Switches for appliances Part 1-1: Requirements for mechanical switches) ICS 29:120:40 K64 National Standards of People's Republic of China Switches for appliances Part 1-1: Requirements for mechanical switches (IEC 61058-1-1:2016, MOD) 2020-12-14 release 2021-07-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee

Table of contents

Foreword Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 General requirements 1 5 General precautions for the test 1 6 Rating 3 7 Category 3 8 Signs and documents 3 9 Protection against electric shock 3 10 Grounding device 3 11 Terminals and ends 3 12 Structure 3 13 Organization 3 14 Anti-solid foreign matter, waterproof and moisture-proof 3 15 Insulation resistance and dielectric strength 3 16 Fever 3 17 Durability 4 18 Mechanical strength 9 19 Screws, current carriers and couplings 9 20 Electrical clearance, creepage distance, solid insulation and coating of hard printed circuit board components 9 21 Fire hazard 9 22 Rust prevention 9 23 Abnormal operation and fault conditions of the switch 9 24 Switching components 10 25 Electromagnetic compatibility (EMC) requirements 10 Reference 11 Table 101 Test sample 1 Table 102 AC electrical durability test load 4 Table 103 DC electrical endurance test load 5 Table 104 Switch operating conditions 7

Foreword

GB/T 15092 "Appliance Switch" is divided into the following parts: ---Part 1: General requirements; ---Part 1-1: Mechanical switch requirements; ---Part 1-2: Requirements for electronic switches; ---Part 2: Special requirements; ● Special requirements for soft cord switches; ● Special requirements for conversion selector; ● Special requirements for independent installation switches; ● Special requirements for hand-held and portable power tools and garden machinery switches: This part is Part 1-1 of GB/T 15092: This section was drafted in accordance with the rules given in GB/T 1:1-2009: This section uses the redrafting method to modify and adopt IEC 61058-1-1:2016 "Appliance Switch Part 1-1: Mechanical Switch Requirements": The technical differences between this part and IEC 61058-1-1:2016 and the reasons are as follows: ---IEC 61058-1-1:2016's 14:3 stipulates: "The humidity treatment is carried out in a humid chamber, and the relative humidity of the air in the chamber is 91%~ Between 95%: In all places where the sample is placed, the air temperature is maintained at any suitable temperature (t) between 20°C and 30°C", Considering that some areas of our country have a humid tropical climate, and all electrical and electronic products in our country use (40±2) ℃ for moisture resistance test, Therefore, this part stipulates: "The humidity treatment is carried out in a humid chamber, and the relative humidity of the air in the chamber is between 91% and 95%: In all places where the sample is placed, the air temperature should be maintained at any suitable temperature (t) between 30°C and 40°C: This requirement is consistent with GB/T 2423:4-2008 adopts the same severity level: ---IEC 61058-1-1:2016 17:5:6 stipulates: "When required in Chapter 13, use 3 samples of different test groups for TC10 test, instead of the sample part in the test sequence of Table 101, pass 17:6:1 (TE1) and 17:6:2 (TE2) to test", consider Considering that 17:6:2 (TE2) is the thermal conformity assessment, which is for the complete sequence test of Chapter 14, Chapter 15, Chapter 16, and Chapter 17: After the assessment, the TC10 test is an institutional assessment conducted using 3 samples from different test groups, and passed 17:6:1 (TE1) and 17:6:3 (TE3) are more reasonable to test, that is, functional qualification and insulation qualification are used to evaluate the test results: So the headquarters Sub-regulations: "When required in Chapter 13, use 3 samples from different test groups for the TC10 test instead of the table 101 test: The sample part of the test sequence is tested through 17:6:1 (TE1) and 17:6:3 (TE3)": This section has made the following editorial changes: ---Added references: This part was proposed by China Electrical Equipment Industry Association: This part is under the jurisdiction of the National Electrical Accessories Standardization Technical Committee (SAC/TC67): Drafting organizations of this section: Shanghai Electric Tool Research Institute (Group) Co:, Ltd:, Zhejiang Zhongxun Electronics Co:, Ltd:, Zhangjiagang Huajie Electronics Co:, Ltd:, Zhejiang Jiaben Electronics Co:, Ltd:, Changzhou Yunjie Electric Co:, Ltd:, Yueqing Huiyang Electromechanical Co:, Ltd:, Zhejiang Guanbao Electronics Co:, Ltd: Co:, Ltd:, Fa-German Electric Co:, Ltd:, Zhejiang Changlong Electric Co:, Ltd:, Southeast Electronics Co:, Ltd:, Zhongshan Yonglian Electrical Products Co:, Ltd: The company, Zhongren Shangdong (Shanghai) Testing Technology Co:, Ltd:, Weikai Testing Technology Co:, Ltd:, Zhejiang Heling Electric Co:, Ltd: The main drafters of this section: Zhang Weichang, Chen Ping, Zheng Jianzhong, Fang Liang, Ni Shenglong, Chu Yunyue, Wu Shiqing, Dai Taiguan, Zhou Jinlong, Xue Daode, Qiu Wenkui, Liang Songwen, Du Juan, Shen Dingli, Yan Qunhua, Qu Hailiang, Xu Yunan, Li Shangchun: Switches for appliances Part 1-1: Requirements for mechanical switches

1 Scope

Chapter 1 of GB/T 15092:1-2020 applies: Add at the end of Chapter 1 of GB/T 15092:1-2020: This part of GB/T 15092 applies to mechanical switching appliances and should be used in conjunction with GB/T 15092:1-2020: Note: Additional requirements for special switches can refer to Part 2 of GB/T 15092:

2 Normative references

The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article Pieces: For undated references, the latest version (including all amendments) applies to this document: Chapter 2 of GB/T 15092:1-2020 applies:

3 Terms and definitions

Chapter 3 of GB/T 15092:1-2020 applies:

4 General requirements

Chapter 4 of GB/T 15092:1-2020 applies:

5 General considerations for the test

After adding the following requirements, GB/T 15092:1-2020 Chapter 5 applies: Added at the end of 5:4: Table 101 provides precautions for the following aspects: ---The minimum number of samples required for each test; --- When adding appropriate tests, the minimum number of total samples required for each evaluation; ---Additional samples required due to increased electrical ratings, specific structures, or damage or rupture during the test: Table 101 Test samples Article number entry minimum number of each test sample a Remarks 5 General precautions for the test-iib

6 Rating

7 categories

8 Signs and documents

1 c
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15092.101-2020_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15092.101-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15092.101-2020_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15092.101-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.