Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 13526-2007 English PDF

US$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 13526-2007: Unplasticized polyvinyl chloride (PVC-U) pipes -- Dichloromethane resistance test method
Status: Valid

GB/T 13526: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 13526-2007189 Add to Cart 3 days Unplasticized polyvinyl chloride (PVC-U) pipes -- Dichloromethane resistance test method Valid
GB/T 13526-1992279 Add to Cart 3 days Unplasticized polyvinyl chloride (PVC-U) pipes--Dichloromethane test Obsolete

Similar standards

GB/T 15558.1   GB/T 10006   GB/T 15560   GB/T 45232   GB/T 43982.11   GB/T 13519   

Basic data

Standard ID: GB/T 13526-2007 (GB/T13526-2007)
Description (Translated English): Unplasticized polyvinyl chloride (PVC-U) pipes -- Dichloromethane resistance test method
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G33
Classification of International Standard: 83.140.30
Word Count Estimation: 7,713
Date of Issue: 2007-12-05
Date of Implementation: 2008-09-01
Older Standard (superseded by this standard): GB/T 13526-1992
Regulation (derived from): China National Standard Approval Announcement2007 No.13 (Total No.113)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the rigid polyvinyl chloride (PVC-U) pipes methylene chloride immersion test method. The quality standards as a rapid control of the production process, to characterize the degree of plasticizing pipe and homogeneity. This standard applies to a variety of uses rigid polyvinyl chloride (PVC-U) pipes.

GB/T 13526-2007: Unplasticized polyvinyl chloride (PVC-U) pipes -- Dichloromethane resistance test method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Unplasticized polyvinyl chloride (PVC-U) pipes. Dichloromethane resistance test method ICS 83.140.30 G33 National Standards of People's Republic of China Replacing GB/T 13526-1992 Hard polyvinyl chloride (P Vp CU) pipe Methylene chloride immersion test method Posted 2007-12-05 2008-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard replaces GB/T 13526-1992 "hard polyvinyl chloride (PVU-U) pipes methylene chloride immersion test method." Compared with GB/T 13526-1992 main changes are. --- By the sample length 100mm to 160mm (see 5.1); --- Heated sample was immersed 20min to 30min (see 7.3); --- In accordance with international standards, the tilt angle of the sample determined according to pipe wall thickness (see 5.2); --- The results of the determination to destroy or no damage, damage percentage calculated ramps and ramps in the circumferential direction to calculate the percentage of damage (see 8.2). This standard reference ISO /DIS9852.2006 (in English), and the technical requirements of ISO /DIS9852.2006 agreement. This standard Annex A, Annex B normative appendix. The standard proposed by China National Light Industry Council. This standard by the National Plastics Standardization Technical Committee of plastic pipe, fittings and valves at the Technical Committee (SAC/TC48/SC3) Centralized. This standard was drafted. Longhai City of Zhangzhou Chiyu Plastic Co., Ltd. of Wuzhou on May 1 plastic products, four Chuan Chuanke Plastic Group, Pipe Co., Ltd. Hebei Baoshuo. The main drafters. Zhang Lin Hong, Huang Wanxia, Yang Huili, Liyan Ying. Hard polyvinyl chloride (P Vp CU) pipe Methylene chloride immersion test method

1 Scope

This standard specifies the hard polyvinyl chloride (PVC-U) pipe methylene chloride immersion test method. This standard as a fast production process quality control, in order to characterize the extent and plastics pipe uniformity. This standard applies to various uses of hard polyvinyl chloride (PVC-U) pipes. Principle 2 2.1 The PVC-U pipes cut to a predetermined length, according to the wall thickness of its end faces cut to a slant angle, in the sample Dichloromethane was immersed in a water bath (30 ± 1) min to test samples in the relevant product standard specifies the extent of the damage temperature. 2.2 Distilled water was added to make a thick seal layer is formed on the methylene chloride, to reduce evaporation to achieve the protective effect. After immersing the sample should be Seal layer disposed in dichloromethane dropwise to the surface of the sample was impregnated, dried and finally check whether the sample destructive.

3 Reagents

3.1 dichloromethane, analytical grade. Warning. dichloromethane low boiling point (40 ℃), at ambient temperature easily gasified. Further, methylene chloride absorption through the skin and eyes Income caused poisoning, when the operating liquid methylene chloride or impregnated samples have sufficient preventive measures. Vapor is also toxic, the maximum concentration allowed Xu limit of 100mL/m3 (ppm). Thus, the container should be kept dry and ventilated storage rooms and places as well as the sample. 3.2 distilled water.

4 device

This standard uses the following instruments and devices. a) bevel cutting instrument; b) a glass or stainless steel container. the right size, under specified conditions capable of receiving one or more samples from the container at the bottom of 10mm Installed with a strainer, cover to limit evaporation of the liquid; c) thermostat. the thermostat unit with stirring, the temperature can dichloromethane cooled to a predetermined temperature, maintaining the temperature of the test solution (T ± 0.5) ℃ within the range; d) hood. fitted with ventilation systems.

5 Sample Preparation

5.1 interception as a sample from the pipe length of 160mm, should be cut perpendicular to the pipe axis, pipe wall thickness of the sample should be larger than the standard Specified minimum wall thickness of the sample. 5.2 bevel cutting should avoid the heat as much as possible. The samples along the entire thickness of the end face of a fall into a slope, the inclination angle to the pipe wall Thick determine the corresponding relationship between the two in Table 1. Table 1 Relationship between the pipe wall thickness and bevel angle
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 13526-2007_English be delivered?

Answer: Upon your order, we will start to translate GB/T 13526-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 13526-2007_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 13526-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 13526-2007?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13526-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.