GB/T 12455-2010 English PDFUS$349.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 12455-2010: The rationality of electricity usage in guesthouse and hotel Status: Valid GB/T 12455: Historical versions
Basic dataStandard ID: GB/T 12455-2010 (GB/T12455-2010)Description (Translated English): The rationality of electricity usage in guesthouse and hotel Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F01 Classification of International Standard: 27.010 Word Count Estimation: 15,133 Date of Issue: 2010-11-10 Date of Implementation: 2011-02-01 Older Standard (superseded by this standard): GB/T 12455-1990 Quoted Standard: GB/T 14549; GB 19210 Regulation (derived from): Announcement of Newly Approved National Standards No. 8 of 2010 (total 163) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the hotels and restaurants of the supply and distribution systems, HVAC, water supply and drainage systems, lighting systems, energy information management and building automation (BA) systems, electricity metering, analysis, and evaluation methods and requirements, This standard applies to existing, running in the one to five-star tourist hotels, restaurants and other hotels, restaurants, guest houses, new buildings can be designed with reference to the corresponding execution, GB/T 12455-2010: The rationality of electricity usage in guesthouse and hotel---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.The rationality of electricity usage in guesthouse and hotel ICS 27.010 F01 National Standards of People's Republic of China Replacing GB/T 12455-1990 Hotels, restaurants and rational use of electricity Issued on. 2010-11-10 2011-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ 1 Scope 1 2 Normative references 1 3 power supply system 1 HVAC 4 1 5 5 to the drainage system 6 Lighting System 6 7 Other 7 8 energy information management and building automation (BA) system 9 9 electricity metering, analysis and evaluation 9ForewordThis standard replaces GB/T 12455-1990 "hotels, restaurants and rational use of electricity." This standard compared with GB/T 12455-1990, the main changes are as follows. --- Original standard in Chapter 4 of the "air conditioning system" made to supplement and improve more content, such as increasing the "air-conditioning energy-saving technologies, air Conditioning system maintenance "and so on; --- To increase the drainage system of rational use of electricity, including maintenance and other content; --- Increased its hotels and restaurants in the kitchen, swimming pool, laundry room and other special places of power requirements; --- Delete the original standard "cold" this part; --- Added "Building Automation" section, including the "Energy Management Information Systems and BA, cold and heat sources and air-conditioning system monitoring", etc. content; --- The original standard "electricity metering Assessment Analysis" section of the supplement and more perfect. This standard by the National Standardization Technical Committee for Energy Management and focal points. This standard was drafted. Tongji University, Anhui Construction Engineering College, Guangzhou Urban Planning Survey and Design Institute, Shandong Architectural Design Research Institute, China National Institute of Standardization, State Grid Corporation of demand side management guidance center, IPPR International Engineering Design and Research Institute, Guangdong Construction Design and Research Institute, Shanghai with Fida Energy Technology Co., Ltd., Johnson Controls Building Equipment Technology (Wuxi) Co., Ltd., Jiangsu know people ventilators Preparation Company, Jiangsu Province, Nanjing Institute of Architectural Design, AIRSYS Services Limited air-conditioning systems. Drafters of this standard. Meng Hua, Wuxi Ping, Cheng Jianhong, Dike Jun, Dai Jian Chao, Yin Yao which Chen Zhong Hua, Zhang Hu, Li Gang, in Xiaoming Chen, Zhao Wencheng, Hong learn new Maowen Ping, Zhang Jianzhong, Jiang Changsheng, Chen Weimin. Hotels, restaurants and rational use of electricity1 ScopeThis standard specifies the hotels and restaurants of the supply and distribution systems, HVAC, water supply and drainage systems, lighting systems, energy information management and building automation Control (BA) system, electricity metering, analysis and evaluation methods and requirements. This standard applies to both, is running from one to five-star standard tourist hotels, restaurants and other hotels, restaurants, guest houses, The new design of the respective buildings can also be implemented by reference.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 14549 Power quality utility grid harmonic GB 19210 air conditioning and ventilation system cleaning specifications3 power supply system3.1 rational supply and distribution 3.1.1 substation should have two line power supply, it is important to be self-independent emergency power load. Its location should be close to the load center, According to the case load distribution, high-rise buildings should be in an intermediate layer disposed substation. 3.1.2 within the substation suffered power supply voltage terminals rated voltage tolerance of the normal range, the offset voltage electrical equipment value should not be large Rated voltage of ± 5%. 3.2 single-phase electrical equipment should be evenly connected to the three-phase network, voltage unbalance supply network should be less than 2%. 3.3 line loss rate to the receiving end of the electrical equipment, a transformer for power supply and distribution system line loss rate should not exceed 3.5%. 3.4 transformer selection, configuration and operation 3.4.1 According to the actual power load, the choice of energy-saving low-loss transformers, the rational allocation of capacity and the number of units of the transformer. 3.4.2 Transformer total loss minimization principle, optimizing transformer operation mode, economically rational allocation of electricity load. 3.5 rational allocation of reactive power compensation equipment, improve the power factor of electricity, electric power factor compensation to be 0.9 or more. 3.6 Variable equipment inside the substation should be equipped with appropriate measurement and measurement instruments. Monitor and record voltage, current, power, power factor, and there are Reactive power, reactive power, power measuring instruments accuracy class of 1.0 to 0.5. Nonlinear loads 3.7 electrical equipment is harmonic source, easy to cause the grid current and voltage waveforms, harmonic pollution, should be taken to suppress Measures harmonics, meet the requirements of GB/T 14549 requirements.4 HVAC4.1 HVAC system 4.1.1 the air conditioning system at run-time indoor temperature and humidity control values in Table 1. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 12455-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 12455-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 12455-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 12455-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 12455-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 12455-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |