GB/T 12164.3-2013 English PDF

US$454.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 12164.3-2013: Reference beta radiations -- Part 3: Calibration of area and personal dosimeters and the determination of their response as a function of beta radiation energy and angle of incidence
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 12164.3-2013454 Add to Cart 3 days Reference beta radiations -- Part 3: Calibration of area and personal dosimeters and the determination of their response as a function of beta radiation energy and angle of incidence Valid

Similar standards

GB 39220   EJ/T 307   GB 18871   GB/T 44645   GB/T 42142   GB/T 42290   

Basic data

Standard ID: GB/T 12164.3-2013 (GB/T12164.3-2013)
Description (Translated English): Reference beta radiations -- Part 3: Calibration of area and personal dosimeters and the determination of their response as a function of beta radiation energy and angle of incidence
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: F74
Classification of International Standard: 17.240
Word Count Estimation: 23,284
Quoted Standard: GB/T 12162.3-2004; GB/T 12164.1; GB/T 12164.3; ISO 6890-1; ISO 6890-2-2004
Adopted Standard: ISO 6980-3-2006.IDT
Regulation (derived from): National Standards Bulletin No. 21 of 2013
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the directional dose equivalent H according to "(0. 07, ��) and personal dose equivalent Hp (0. 07) to determine the calibration and radiation protection dose (rate) instrument response, and to determine the dose (rate) meter energy

GB/T 12164.3-2013: Reference beta radiations -- Part 3: Calibration of area and personal dosimeters and the determination of their response as a function of beta radiation energy and angle of incidence



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Reference beta radiations Part 3.. Calibration of area and personal dosemeters and the determination of their response as a function of beta radiation energy and angle of incidence ICS 17.240 F74 National Standards of People's Republic of China β reference radiation - Part 3. Location and personal dose Instrument calibration and energy response and angular response is determined Referencebetaradiations-Part 3. Calibrationofareaandpersonaldosemeters (ISO 6980-3.2006, IDT) Issued on. 2013-10-10 2014-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 applies to all sites and personal dosimeters calibration procedure 7 5 special place dosimeter calibration procedure 10 6 personal dosimeter special calibration procedure 10 7 Expression of results 11 Appendix A (normative) Symbols and Abbreviations 13 Appendix B (normative) Reference conditions 15 Annex C (informative) Some β reference radiation field conversion coefficient of 17 References 19

Foreword

GB/T 12164 "β reference radiation" is divided into three parts. --- Part 1. generating method; --- Part 2. Characterization of the radiation field and a substantial amount of relevant calibration basis; OK place and personal dosimeters calibrated response and its energy and angular response. Part --- 3. This section GB/T Part of 312,164. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method identical with ISO 6980-3.2006 "β reference particle radiation - Part 3. Location and personal dosimeter Calibration and the energy and angular response is determined. " Consistency correspondence with international standards in this standard references of the following documents. --- GB/T 12164.1-2008 β reference radiation - Part 1. production method (ISO 6980-1.2006, IDT). And ISO 6980-3.2006 as compared to, for ease of use, this section made the following editorial changes. --- 4.1.1 change the title "Select Source" and cancel 4.1.1.1 title. This part is proposed by the China National Nuclear Corporation. This part of the National Nuclear Energy Standardization Technical Committee (SAC/TC58) centralized. This section drafted by. China Institute of Atomic Energy. The main drafters of this section. Wei Kexin, Wang Hongyu, Song Mingzhe, Yang Jing. β reference radiation - Part 3. Location and personal dose Instrument calibration and energy response and angular response is determined

1 Scope

Given radiation protection dose (rate) meter response, and determining the dose (rate) meter energy response and angular response methods. This section applies to a calibration and determine the amount of practical ICRU radiation protection dose (rate) meter response. This section does not apply to fixed place dosimeter field calibration.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 12162.3-2004 for calibrating dosemeters and dose rate meters and for determining their response of X and γ reference radiations 3 . Determination of the calibration response and energy and angular response of dosimeters and workplace personal dosimeter (ISO 4037-3.1999, IDT) GB/T 12164 (all parts) β radiation reference ISO 6980-1 nuclear β reference radiation particles - Part 1. production method (Nuclearenergy-Referencebeta-particle radiation-Part 1. Methodsofproduction) ISO 6980-2.2004 Nuclear β reference particle radiation - Part 2. Characterization of the radiation field and the fundamental basis of the amount of the relevant calibration (Nuclearenergy-Referencebeta-particleradiation-Part 2. Calibrationfundamentalsrelatedtobasic quantitiescharacterizingtheradiationfield) No. ICRU51 Report. Quantities and units (Quantitiesandunitsinradiationprotection 1993 Radiation Protection Dosimetry dosimetry) International Basic and General Terms in Metrology (VIM), BIPM/IEC /International Federation of Clinical Chemistry/International Standard Organization for Standardization/International Union of Pure and applied chemistry/International Union of Pure and Applied Physics/international legal metrology organizations [International vocabularyofbasicandgeneraltermsinmetrology (VIM), BIPM/IEC /IFCC/ISO /IUPAC/IUPAP / OIML]

3 Terms and Definitions

No. ICRU51 and the following terms and definitions are defined reports and VIM apply to this document. 3.1 ICRU tissue ICRUtissue Density of material 1g · cm-3, the quality of the group is divided into. O. 76.2%; H. 10.1%; C. 11.1%; N. 2.6%. Note. See report No. ICRU39. 3.2 Β largest energy maximumbetaenergy Emax One or several specific β particle-emitting nuclide in a continuous spectrum of maximum energy.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 12164.3-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 12164.3-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 12164.3-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 12164.3-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.