Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 11205-2009 English PDF

US$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 11205-2009: Determination of thermal conductivity of rubber wire method
Status: Valid

GB/T 11205: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 11205-2009189 Add to Cart 3 days Determination of thermal conductivity of rubber wire method Valid
GB/T 11205-1989199 Add to Cart 2 days Rubber--Determination of thermal conductivity by means of transient hot-wire method Obsolete

Similar standards

GB/T 7762   GB/T 7759.2   GB/T 10707   GB/T 15340   GB/T 11210   GB/T 11206   

Basic data

Standard ID: GB/T 11205-2009 (GB/T11205-2009)
Description (Translated English): Determination of thermal conductivity of rubber wire method
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G40
Classification of International Standard: 83.060
Word Count Estimation: 8,866
Date of Issue: 2009-04-24
Date of Implementation: 2009-12-01
Older Standard (superseded by this standard): GB/T 11205-1989
Regulation (derived from): PRC National Standard Approval Announcement 2009 No.6 (Total No.146)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the method for measuring the thermal conductivity of rubber material with hot method. This standard applies to the determination of uncured rubber vulcanized rubber and thermal conductivity. This standard does not apply to water swelling rubber rubber and metal powders.

GB/T 11205-2009: Determination of thermal conductivity of rubber wire method

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of thermal conductivity of rubber wire method ICS 83.060 G40 National Standards of People's Republic of China Replacing GB/T 11205-1989 Determination of the thermal conductivity of rubber wire method Posted 2009-04-24 2009-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard replaces GB/T 11205-1989 "rubber thermal conductivity measurement of transient hot wire method." The main technical differences between standard compared with GB/T 11205-1989 as follows. --- Modify the standard name; --- Increased warnings; --- Deleted provisions thermal conductivity test range (see Chapter 1); --- The definition of thermal conductivity supplemented (see Chapter 3); --- Added a sample size of 50mm × 6.3mm (1989 Edition 6.3; 6.4 edition); --- Adjust the sample has been modified (see 7.2); --- Remove the formula test error (1989 edition 8.6); --- Added "test results to three significant figures" (edition 9.2). The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standards Commission Oak Common test methods for Standardization Technical Committee (SAC/TC35/SC2) centralized. This standard was drafted. Northwest Rubber Plastic Research and Design Institute. The main drafters of this standard. Gao Yun, Zhu Wei. This standard replaces the standards previously issued as follows. --- GB/T 11205-1989. Determination of the thermal conductivity of rubber wire method Warning. Use of this standard laboratory staff should have regular experience. This standard does not point out all possible security issue, use Those who have the responsibility to take appropriate safety and health practices and to ensure compliance with the relevant provisions of state laws and regulations.

1 Scope

This standard specifies the method for determining the thermal conductivity of the rubber material with a hot wire method. This standard applies to the determination of vulcanized rubber and unvulcanized rubber thermal conductivity. This standard does not apply to water-swellable rubber, rubber and metal powder.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2941 rubber physical test method for preparing and conditioning General Procedure (GB/T 2941-2006, ISO 23529.2004, IDT)

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 Under heat transfer conditions represent two plane temperature difference per unit length apart as one unit (K) when, in unit time through unit area Product heat transfer. Units of W/(m · K).

4 Test principle

The use of thermal resistance material made of a plane probe, making it as a heat source and a temperature sensor. Thermal coefficient resistance temperature of the material --- And a linear relationship between the degree of resistance that by understanding the change in resistance can know the heat loss, reflecting the thermal properties of the samples. In the test Process, the probe is placed in the middle of two samples tested, the current through the resistance of the material to produce a certain amount of heat, the temperature rises, The heat generated at the same time to the two sample diffusion, diffusion rate depends on the heat transfer characteristics of the material. By responding to and recording temperature probe Time, the properties of the material can be calculated. A constant current I, will be produced per unit length q = I 2R (R being the wire resistance, L is the length of the wire) of Joule heat. Heat will lead week It conforms to the following mathematical relationship between. 4πλ - [] C (1) Where. λ --- thermal conductivity of the medium, in units of watts per meter Kelvin [W/(m · K)]; Thermal diffusivity Rao --- medium, in units of meters per second (m2/s); C --- Euler's constant, to 0.5772; T0 --- initial temperature when the unit is Kelvin (K);
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 11205-2009_English be delivered?

Answer: Upon your order, we will start to translate GB/T 11205-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 11205-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 11205-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 11205-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11205-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.