Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 11017.2-2024 English PDF

US$439.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 11017.2-2024: Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV) and 110 kV (Um=126 kV) - Part 2: Power cables
Status: Valid

GB/T 11017.2: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 11017.2-2024439 Add to Cart 4 days Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV) and 110 kV (Um=126 kV) - Part 2: Power cables Valid
GB/T 11017.2-2014529 Add to Cart 4 days Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 110kV (Um=126kV) -- Part 2: Power cables Valid
GB/T 11017.2-2002679 Add to Cart 5 days Rated voltage of 110kV XLPE insulated power cable rated voltage of 110kV XLPE insulated power cables and accessories -- Part 2: Obsolete

Similar standards

GB/T 9330   GB/T 12706.1   GB/T 12528   GB/T 11017.3   GB/T 11017.1   GB/T 11017.3   

Basic data

Standard ID: GB/T 11017.2-2024 (GB/T11017.2-2024)
Description (Translated English): Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV) and 110 kV (Um=126 kV) - Part 2: Power cables
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K13
Classification of International Standard: 29.060.20
Word Count Estimation: 22,234
Date of Issue: 2024-09-29
Date of Implementation: 2025-04-01
Older Standard (superseded by this standard): GB/T 11017.2-2014
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 11017.2-2024: Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV) and 110 kV (Um=126 kV) - Part 2: Power cables


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29.060.20 CCSK13 National Standard of the People's Republic of China Replaces GB/T 11017.2-2014 Rated voltage 66kV (Um=72.5kV) and 110kV (Um=126kV) Cross-linked polyethylene insulated power cable and its accessories Part 2.Cables 110kV(Um=126kV)-Part 2.Powercables Released on 2024-09-29 2025-04-01 Implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Usage Features 1 5 Product naming 2 6 Technical Requirements 3 7 Finished Cable Marking 8 8 Tests and requirements 8 9 Acceptance Rules11 10 Packaging, transportation and storage 11 Appendix A (Informative) Cable usage conditions 13 Appendix B (Informative) Properties of Insulating and Semiconducting Materials 14 Appendix C (Informative) Properties of Semiconducting Buffer Tapes 15 References 16 Table 1 Typical models and names of cables 3 Table 2 Nominal thickness of insulation layer 4 Table 3 Nominal thickness of metal sleeve 7 Table 4 Nominal thickness of non-metallic outer sheath 8 Table 5 Test categories and codes 9 Table 6 Cable routine test (R) items and requirements 9 Table 7 Cable sampling test (S) items and requirements 9 Table 8 Type test (T) items and requirements 10 Table B.1 Properties of cable insulation and semi-conductive materials 14 Table C.1 Product name and model 15 Table C.2 Product performance 15

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document is GB/T 11017 "Rated voltage 66kV (Um=72.5kV) and 110kV (Um=126kV) cross-linked polyethylene insulation Power cables and their accessories" Part 2.GB/T 11017 has been published in the following three parts. --- Part 1.Test methods and requirements; --- Part 2.Cables; --- Part 3.Cable accessories. This document replaces GB/T 11017.2-2014 "Rated voltage 110kV (Um=126kV) cross-linked polyethylene insulated power cables and their Annex Part 2.Cables, compared with GB/T 11017.2-2014, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Added the provisions and corresponding requirements for rated voltage 66kV (Um = 72.5kV) (see Chapter 1, 4.1 and Chapter 6); --- Added the code and requirements for flat aluminum sleeves (see 5.1, Table 1 and Table 3); --- Added the code and requirements for flame retardant sheath and halogen-free low-smoke flame retardant sheath (see 5.1, Table 1 and 6.7); --- Added cable combustion characteristics code and requirements (see 5.1, Table 1 and Table 8); --- Changed the technical requirements for conductors (see 6.1, 6.1 of the.2014 edition); --- Increased the performance of semi-conductive buffer tape (see 6.4.1); --- Changed the diameter requirements for shielded copper wire (see 6.5.2, 6.5.2 of the.2014 edition); --- Changed the requirements for metal sleeve materials (see Table 6.6.1, 6.6.1 of the.2014 edition); --- Changed the provisions for the nominal thickness of non-metallic sheath (see Table 4, Table 4 of the.2014 edition); --- Changed the type test items and requirements (see Table 8, Table 8 of the.2014 edition). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the China Electrical Equipment Industry Association. This document is under the jurisdiction of the National Technical Committee for Standardization of Wire and Cable (SAC/TC213). This document was drafted by. Shanghai Cable Research Institute Co., Ltd., China Electric Power Research Institute Co., Ltd., Shanghai Guolan Testing Co., Ltd. Ltd., Qingdao Hancable Co., Ltd., TBEA Shandong Luneng Taishan Cable Co., Ltd., Hangzhou Cable Co., Ltd., Baosheng High Cable Co., Ltd., Chongqing Taishan Cable Co., Ltd., Zhongtian Technology Submarine Cable Co., Ltd., Hangzhou Huaxin Power Cable Co., Ltd., Jiang Suhengtong High Voltage Submarine Cable Co., Ltd., Jiangsu Shangshang Cable Group Co., Ltd., Shenyang Furukawa Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd. Co., Ltd., Zhejiang Chenguang Cable Co., Ltd., Zhejiang Wanma Co., Ltd., Yangzhou Shuguang Cable Co., Ltd., Guangzhou Nanyang Cable Group Group Co., Ltd., Fujian Nanping Sun Cable Co., Ltd., Ningbo Dongfang Cable Co., Ltd., New Far East Cable Co., Ltd., Guangzhou Lingnan Cable Co., Ltd. and Ningbo Qiuguan Cable Co., Ltd. The main drafters of this document are. Sun Jiansheng, Ouyang Benhong, Fan Yujun, Zhang Yanhua, Long Haiyong, Teng Zhaofeng, Zhu Baojun, Zhang Ya, Xia Yunhai, Guo Haijun, Qiao Yuchang, Li Haohao, Song Liya, Ma Zhuang, Yue Zhenguo, Liu Huanxin, Hu Jianhong, Wang Zhihui, Fan Defa, Ye Xinhong, Xu Jing, Deng Shenghua, Wen Shanghai. The previous versions of this document and the documents it replaces are as follows. ---First published in 1989 as GB/T 11017-1989; --- The first revision in.2002 was adjusted to GB/T 11017.2-2002, and the second revision in.2014; ---This is the third revision.

Introduction

Rated voltage 66kV and 110kV power cables are widely used in power transmission networks, in urban power grids, large enterprises, and new energy power generation. GB/T 11017 is a product standard for power cables and accessories with rated voltages of 66kV and 110kV. The naming rules, test methods, technical requirements, etc. of power cables and accessory systems are planned to be composed of three parts. --- Part 1.Test methods and requirements. The purpose is to specify the general Requirements for test methods and procedures. --- Part 2.Cables. The purpose is to unify the classification, naming, structure and technical specifications of power cables with rated voltages of 66 kV and 110 kV. Technical requirements. --- Part 3.Cable accessories. The purpose is to unify the classification, naming, Structural and technical requirements. Rated voltage 66kV (Um=72.5kV) and 110kV (Um=126kV) Cross-linked polyethylene insulated power cable Part 2.Cables and their accessories

1 Scope

This document specifies the basic structure, model name, and specifications of copper core and aluminum core cross-linked polyethylene insulated power cables with rated voltages of 66kV and 110kV. name, technical requirements, test and acceptance rules, packaging, transportation and storage. This document applies to the design, manufacture and application of single-core power cables with rated voltages of 66kV and 110kV under normal laying and operating conditions. test.

2 Normative references

The contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 3956 Cable conductors GB/T 6995.3 Wire and cable identification marking method Part 3.Wire and cable identification marking GB/T 11017.1-2024 Rated voltage 66kV (Um=72.5kV) and 110kV (Um=126kV) cross-linked polyethylene insulation Power cables and their accessories Part 1.Test methods and requirements JB/T 10181.11 Calculation of cable current carrying capacity Part 11.Current carrying capacity formula (100% load factor) and loss calculation general Regulation

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 approximate value The value is neither guaranteed nor checked. Note. Usually used for calculation of other dimension values. 3.2 A composite sheath having a longitudinally wrapped metal tape or a longitudinally wrapped metal foil bonded to the non-metallic outer sheath of the cable, the metal tape (foil) of the composite sheath being bonded to the outer sheath of the cable. The seams are bonded by melting plastic or adhesive to form a watertight seal. Note. Usually the metal layer is bonded to the polyethylene sheath to form a metal-composite polyethylene sheath.

4 Usage Features

4.1 Rated voltage Rated voltage is the reference voltage for cable design and electrical performance testing. This document uses U0/U and Um as symbols. The meanings of these symbols are as follows.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 11017.2-2024_English be delivered?

Answer: Upon your order, we will start to translate GB/T 11017.2-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 11017.2-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 11017.2-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 11017.2-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11017.2-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.