GB/T 10685-2007 English PDFUS$319.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10685-2007: Wool -- Determination of fiber diameter -- Projection microscope method Status: Valid GB/T 10685: Historical versions
Basic dataStandard ID: GB/T 10685-2007 (GB/T10685-2007)Description (Translated English): Wool -- Determination of fiber diameter -- Projection microscope method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: W21 Classification of International Standard: 59.060.10 Word Count Estimation: 12,180 Date of Issue: 2007-06-21 Date of Implementation: 2007-09-01 Older Standard (superseded by this standard): GB/T 10685-1989 Quoted Standard: GB/T 6978; GB/T 8170; GB/T 14269 Adopted Standard: ISO 137-1975, MOD Regulation (derived from): China National Standard Announcement 2007 No.7 (Total No.107) - National-Standard-Commission Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies test methods for measuring the diameter of the wool fiber projection microscope. This standard applies to all types of plush fibers and has undergone a variety of treatments with no significant cross-section of a variant of the plush fibers, other fibers also apply nearly circular in cross-section. GB/T 10685-2007: Wool -- Determination of fiber diameter -- Projection microscope method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Wool. Determination of fiber diameter. Projection microscope method ICS 59.060.10 W21 National Standards of People's Republic of China Replacing GB/T 10685-1989 Wool fiber diameter test methods Projection microscope method (ISO 137. 1975, MOD) Posted 2007-06-21 2007-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis revised standard adopts ISO 137. 1975 "Determination of wool fiber diameter projection microscopy" (in English). This standard and ISO 137. 1975 main technical difference. --- Greasy hair, wash hair test specimen sampling methods. Method A sampling of this standard with ISO 137, when the arbitration; taking into account the party A method of complexity, this increases the standard method B, multi-point sampling method for routine testing; --- With ISO 137. 1975 compared to an increase of preparation loose fiber test specimen; --- Change the calculation formula. ISO 137. 1975 is calculated by assuming that the average diameter of the standard use more scientific weighted average Diameter calculation. This standard replaces GB/T 10685-1989 "Standard Test Method for wool fiber diameter projection microscopy." This revision combined with the usage was amended as follows. --- Increasing the scope of this standard also applies plush fiber diameter detection (1989 Edition Chapter 1; Chapter 1 of this edition); --- Adds a reference standard (Chapter 2 of this edition); --- Added three terminology (Excerpts 3.4,3.6,3.7); --- Modify the batch samples, laboratory samples, the definition of the test specimen (1989 version 3.2,3.3,3.4; this edition 3.2,3.3,3.5); --- Modified wedge method B-foot range (1989 Version 5.2; 5.2 edition); --- Increased viscous media should not be used (1989 Version 5.5; 5.5 edition); --- Clear standard sampling methods (1989 edition 7.1 and 10.1; edition 7.1 and 8.1); --- Modified method B tops test specimens cut length (1989 version 10.3.2; this version 8.3.2); --- Increasing the bulk fiber sample preparation (edition 7.4 and 8.4); --- Modify the title and represented by the formula calculation results (1989 version 9.1 and 12.1; 10.1 edition); --- Revised standard formatting (see Chapters 7 and 8); --- Combined original Appendices A and B, and modify the format of Appendix A. The Standard Appendix A, Appendix B is an informative annex. The standard proposed by China Fiber Inspection Bureau. The standard by the China Fiber Inspection Bureau. This standard was drafted. Shanghai Fibre Inspection. The main drafters of this standard. Pu Song Dan, Chen Shaomin, Hubei Fen. This standard was first released in 1989, this is the first revision. Wool fiber diameter test methods Projection microscope method1 ScopeThis standard specifies the test methods for wool fiber diameter was measured using a projection microscope. This standard applies to all types of fiber and plush undergone various treatments with no significant cross-section of a variant of the pile fibers, also Other suitable cross-section close to the circular fibers.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 6978 Greasy hair wash test method oven method GB/T 8170 numerical rounding rules GB/T 14269 wool test sampling methods3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 Wool or other fiber longitudinal projection of the average width. 3.2 One or more of the packaging unit from a predetermined number of products at random, and as a source of laboratory samples. 3.3 According to the provisions taken from the lot sample product unit or part of the material, as a source of the test sample. 3.4 Samples taken from the lot sample or laboratory sample for a test project, should be representative, and a foot into a test specimen Enough amount. 3.5 Drawn from the test sample in a sample for testing. 3.6 The test sample is thoroughly mixed tile batt uniform thickness, from 16 distribution substantially uniform region, from both random batt 32 points of the surface portion of the sample extraction method. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10685-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 10685-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 10685-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10685-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 10685-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10685-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |