GB/T 10267.3-2008 English PDFUS$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10267.3-2008: Method for analysis of calcium metal -- Part 3: Direct determination of iron, nickel, copper, manganese and magnesium in calcium metal by atomic absorption spectrophotometry Status: Valid GB/T 10267.3: Historical versions
Basic dataStandard ID: GB/T 10267.3-2008 (GB/T10267.3-2008)Description (Translated English): Method for analysis of calcium metal -- Part 3: Direct determination of iron, nickel, copper, manganese and magnesium in calcium metal by atomic absorption spectrophotometry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H12 Classification of International Standard: 77.120.70 Word Count Estimation: 6,667 Date of Issue: 2008-07-02 Date of Implementation: 2009-04-01 Older Standard (superseded by this standard): GB/T 10267.3-1988 Quoted Standard: GB/T 4864 Regulation (derived from): National Standard Approval Announcement 2008 No.11 (Total No.124) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the calcium metal in iron, Nickel, copper, manganese, determination of magnesium. This section applies to metallic iron prepared by electrolysis of calcium in the distillation method, Nickel, determination of magnesium, copper, manganese. Detection limit: Iron 20��g/g, Nickel 20��g/g, Copper 10��g/g, magnesium 20��g/g, Manganese 10��g/g. GB/T 10267.3-2008: Method for analysis of calcium metal -- Part 3: Direct determination of iron, nickel, copper, manganese and magnesium in calcium metal by atomic absorption spectrophotometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Method for analysis of calcium metal Part 3. Direct determination of iron, nickel, copper, manganese and magnesium in calcium metal by atomic absorptiom spectrophotometry ICS 77.120.70 H12 National Standards of People's Republic of China Replacing GB/T 10267.3-1988 Calcium metal analysis Part 3. Direct determination by atomic absorption spectrophotometry Iron, nickel, copper, manganese, magnesium Posted 2008-07-02 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 10267 "Method for analysis of calcium metal" is divided into five parts. --- Part 1. Determination of chlorine chloride ion selective electrode method; --- Part 2. Spectrophotometric determination of trace amounts of silicon; --- Part 3. Direct determination by atomic absorption spectrophotometry of iron, nickel, copper, manganese, magnesium; --- Part 4. 8-quinolinol - chloroform extraction spectrophotometric determination of aluminum; --- Part 5. Distillation - Nessler reagent spectrophotometric determination of nitrogen. This section GB/T Part of 310,267. This Part replaces GB/T 10267.3-1988 "calcium metal analysis by atomic absorption spectrometry direct determination of iron, nickel, copper, manganese, magnesium." This section compared with the GB/T 10267.3-1988, the main differences are as follows. --- Increasing the normative references; --- Like the hydrochloric acid solution of nitric acid to dissolve the sample; --- The self-made standard stock solution to a standard solution; --- Adjust the measurement range; --- Adjust the concentration of the standard solution and the sample solution. This part is proposed by the China National Nuclear Corporation. This part of the National Nuclear Energy Standardization Technical Committee (SAC/TC58) centralized. This section was drafted by. China North Nuclear Fuel Limited. The main drafters of this section. Helen Feng, Li Aijun, Zhao Haisheng, late new country. This part of the standard replaces the previous editions are. --- GB/T 10267.3-1988. Calcium metal analysis Part 3. Direct determination by atomic absorption spectrophotometry Iron, nickel, copper, manganese, magnesium1 ScopeGB/T 10267 provisions of this part of the metal calcium, iron, nickel, copper, manganese, magnesium determination. This section applies to iron, nickel, copper, manganese, magnesium measured prepared by electrolysis of distilled calcium metal. Detection limit. iron 20μg/g; Nickel 20μg/g; copper 10μg/g; magnesium 20μg/g; Mn 10μg/g.2 Normative referencesThe following documents contain provisions which, through reference GB/T 10267 in this section, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 4864 calcium metal and its products Principle 3 Calcium metal sample is dissolved in nitric acid, and diluted appropriately in accordance with the content of the analyte under selected conditions, the use of background correction and groups Matching method with atomic absorption spectrophotometer measured directly measured elements. Product 2 times the upper limit of the concentration of coexisting elements do not affect Determination.4 ReagentsUnless otherwise indicated, the method of water are deionized water, the reagents were of analytical grade reagents. Calcium oxide 4.1 Reference. 99.99%. Nitric acid 4.2. 1 + 1, with a superior grade of pure nitric acid (ρ = 1.42g/mL) and water formulated. 4.3 iron standard solution. ρ (Fe) = 1000μg/mL, 2% HNO3 medium, commercially available. 4.4 Nickel standard solution. ρ (Ni) = 1000μg/mL, 2% HNO3 medium, commercially available. 4.5 Copper standard solution. ρ (Cu) = 1000μg/mL, 2% HNO3 medium, commercially available. 4.6 Manganese standard solution. ρ (Mn) = 1000μg/mL, 2% HNO3 medium, commercially available. 4.7 Magnesium standard solution. ρ (Mg) = 1000μg/mL, 2% HNO3 medium, commercially available. 4.8 iron, nickel, copper, manganese mixed standard solution. each standard solution were taken 4.3,4.4,4.5,4.6 1.00mL, placed in 100mL capacity Bottle, add 2mL nitric acid (4.2), dilute to the mark and mix, spare, this solution iron, nickel, copper, manganese concentration of 10μg/mL. 4.9 Magnesium standard solution. ρ (Mg) = 4μg/mL. Take 10.00mL magnesium standard solution (4.7), placed in 100mL volumetric flask, add 2mL nitric acid (4.2), dilute to the mark and mix dubbed 100μg/mL of solution, then take 2mL100μg/mL solution in 50mL Flask, add 1mL of nitric acid (4.2), dilute to the mark and mix and set aside. 4.10 calcium base solution. ρ (Ca) = 100mg/mL. Weigh 14.00g baseline calcium oxide (4.1) in 200mL beaker, 10mL of nitric acid (3.2) was dissolved into 100mL volumetric flask, add 2mL nitric acid (4.2), dilute to the mark and mix. 4.11 calcium base solution. ρ (Ca) = 20mg/mL. Calcium-based precursor solution of 10mL (4.10) in 50mL volumetric flask, add 1mL nitrate Acid (4.2), dilute to the mark and mix. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10267.3-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 10267.3-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 10267.3-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10267.3-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 10267.3-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10267.3-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |