GB 4706.88-2008 English PDFUS$514.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 4706.88-2008: Household and similar electrical appliances -- Safety -- Particular requirements for wet and dry vacuum cleaners, including power brush, for industrial and commercial use Status: Valid
Basic dataStandard ID: GB 4706.88-2008 (GB4706.88-2008)Description (Translated English): Household and similar electrical appliances -- Safety -- Particular requirements for wet and dry vacuum cleaners, including power brush, for industrial and commercial use Sector / Industry: National Standard Classification of Chinese Standard: K09 Classification of International Standard: 13.120 Word Count Estimation: 26,249 Date of Issue: 2008-06-13 Date of Implementation: 2009-07-01 Adopted Standard: IEC 60335-2-69-1997, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 10 of 2008 (total 123) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Chinese standard applies to electric vacuum cleaner and includes specifically designated for industrial and commercial use, with or without attachments wet suction, dry suction or dry and wet suction apparatus and stationary equipment, such as from the workbench and production equipment for removing dust and the like with a suction device. Note: The commercial is for hotels, schools, hospitals, factories, shops and office use, rather than for general household purposes. This standard also applies to the collection of unwanted dust, such as asbestos, or a liquid with additional apparatus required. This standard also applies to the original motivation for the use of other forms of energy appliances, but their effects must be considered. Review: replaced by the following Note 3 of the first two lines: -G GB 4706.88-2008: Household and similar electrical appliances -- Safety -- Particular requirements for wet and dry vacuum cleaners, including power brush, for industrial and commercial use---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Household and similar electrical appliances.Safety.Particular requirements for wet and dry vacuum cleaners, including power brush, for industrial and commercial use ICS 13.120 K09 National Standards of People's Republic of China GB 4706.88-2008/IEC 60335-2-69.1997 Household and similar electrical appliances - Safety Industrial and commercial driving force of the brush Particular requirements for wet and dry vacuum cleaners (IEC 60335-2-69.1997, IDT) Published 2008-06-13 2009-07-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China issued Table of ContentsPreface Ⅰ IEC Foreword Ⅱ 1 Scope 1 2 Definitions 1 3 2 general requirements General conditions for 4 Test 2 5 Void 2 6 Category 2 7 Marking and instructions 2 8 Protection against access to live parts 3 Start electric appliance 3 9 10 Power input and current 3 11 heat 3 12 Void 3 Leakage current and electric strength at the operating temperature of 13 3 14 Void 3 3 15 Moisture resistance 16 Leakage current and electric strength 4 Transformer 17 and associated circuitry overload 4 18 Endurance 4 19 non-working properly 5 5 20 Stability and mechanical hazards 5 21 Mechanical strength 22 Structure 5 Internal wiring 23 6 6 element 24 25 and the external power connection cord 6 26 with the external lead terminals 7 27 grounding measures 7 7 and screw 28 is connected 29 creepage distance and clearance distance through insulation 7 30 heat, fire resistance and tracking 7 31 7 rust 32 radiation, toxicity and similar hazards 7 Impact test apparatus 101 of FIG. 7 Appendix 8 Annex A (normative) Normative References 8 Particular requirements for Annex AA (normative) collecting dust hazardous to health with a vacuum cleaner, garbage sweeper and dust collector 9 Risk of explosion of dust Table 15 Appendix BB (informative) suffered initiation condition Figure AA. 1 warning label 14 GB 4706.88-2008/IEC 60335-2-69.1997ForewordGB 4706 all technical contents of this section is mandatory. This section is equivalent to using IEC 60335-2-69 "Household and Similar Electrical Appliances - Safety - Part 2. Industrial and commercial driving force of the brush Particular requirements for wet and dry vacuum cleaners "(1997) Second Edition. This section should GB 4706.1-1998 "Household and Similar Electrical Appliances - Safety Part 1. General Requirements," with the use. Safety Household and Similar Electrical Appliances consists of two parts, a first part of a universal requirement, the second part of a special security products Claim. This section states that "suitable" section, indicates that the corresponding provision in this section apply to 4706.1-1998 GB ; stated in this section "Instead of" section, this section shall prevail provisions; "modify" part of this section stated, represents the corresponding GB 4706.1-1998 Provisions relevant content should be content after this section takes effect, and the contents of the other provisions of this section still apply; write in this section That "increasing" section, showing in addition to the corresponding provision in line with GB 4706.1-1998, this section shall comply with the added provision. This section will reference IEC 312. 1981 standard to the respective national standard GB/T 20291-2006 "domestic vacuum cleaners of To test method "(IEC 60312.2004, IDT). Appendices Appendix properties in this section by the predetermined attribute GB 4706.1-1998. This part of the increase in the terms of notes and charts should be numbered starting from 101 onwards. This section was proposed by China Light Industry Federation. This part of the jurisdiction of the National Standardization Technical Committee appliances Electrical Business Services Sub-Committee appliance diet. This section was drafted. Zhejiang Business University, Beijing Institute of Mechanical Services. This part mainly drafted. Hong Wang flat, Fu Yuying, Li Jiping, Ho spring, JOURNAL OF HUMAN Liu Xu, Shang Weidong. GB 4706.88-2008/IEC 60335-2-69.1997 IEC Foreword 1) The International Electrotechnical Commission (IEC ) is the global standardization set by Member States Electrotechnical Commission (IEC National Committees) composed of Weaving. IEC 's mission is to promote international cooperation in the electrical and electronic fields all issues related to standardization of. For this purpose, IEC addition Other activities, but also promulgated international standards. Its formulation is entrusted to technical committees. Any interest in the issues involved IEC National Committee may participate in this work. Contact with the IEC international organizations, government agencies and civil society can take part. IEC and the International Organization for Standardization (ISO ) in close cooperation in accordance with the conditions specified in the agreement between the two organizations. 2) Technical Committee with the participation of all countries concerned of the Committee established by IEC formal decisions on technical matters or co Yee, as close as possible to express the consensus of opinion on the issues involved in the international arena. 3) Documents presented in the form of recommendations for international use and are published in the form of standards, technical reports or guides, and in this meaning Righteousness is accepted by the National Committees. 4) In order to promote international unification, IEC National Committees undertake much as possible to international standards IEC unmistakably apply to National and regional standards to go. Any inconsistency between the IEC Standard and the corresponding national and regional standards should be standard in countries and regions Clearly articulated. 5) IEC provides no recognized mark, nor responsible for any claims that meet their particular standard equipment. 6) notes that some part of this standard has become patentable subject matter may, IEC does not identify any or all patent rights commitments Bear responsibility. IEC 60335 series of standards of this part by the IEC on 61 61J "Household and similar electrical appliances" belongs to the Technical Committee "Industrial cleaning electric appliances" sub-committee to develop. The second edition of IEC 60335-2-69 cancels and replaces the first edition published in 1992. The text of this standard is based on the following documents. FDIS Report on voting 61J/57/FDIS 61J/72/RVD Details of voting on the approval of this standard can identify the voting report indicated in the above table in. This second part is ready to be used in conjunction with IEC 60335-1 and the latest version of Amendment, it is based on the third edition of the standard Established (1991) basis. This second portion IEC 60335-1 supplement or modify the terms corresponding to the IEC standard into. industrial and commercial driving force of the wet brush Special requirements or dry cleaners. Appendix AA is part of the standard as a whole. Appendix BB provide information only. Appendix AA does not include detailed content filtering trial to consider. Test by the SC61J consider are. 1) condensation nuclei (the CN); 2) an oil dispersion of fine particles (the DOP); 3) Sodium chloride (NaCI); 4) limestone dust. If the individual terms of the first part of the second part when this is not mentioned, if justified, the provisions still apply. Description "by this standard When adding "," Edit "or" replacement ", the relevant portion of the first body should be modified accordingly. Note. 1) Use the following typographic fonts. --- requirement itself. roman; GB 4706.88-2008/IEC 60335-2-69.1997 --- test specifications. italic; --- Description Matters. Small roman. Text in bold are defined in Chapter 2. When a portion defining a first involves an adjective, adjective in the second portion and the associated The term also bold. 2) increase in terms of IEC 60335-1, notes and charts should be numbered starting from 101 onwards, additional annexes indicate letters AA, BB and so on. Additional differences exist in the following countries. --- 2.2.9. specifies the different types of carpet (United States) in A1.1.2 IEC 60312's. --- 6.1. In some countries, allow a class 0 and class 0Ⅰ vacuum cleaner (Japan); When using the portable appliance may be a type Ⅰ, Ⅱ or Class Ⅲ (USA). --- 7.1. call for additional signs (USA). --- 7.9. If there should be an indicator electrode driving brush (United States). --- 7.12. requires additional instructions (United States). --- 15.2. Different tests are carried out (USA). 22.2 ---. no all-pole switching power supply circuit is turned off the water suction cleaning appliance. --- 25.5. Y-type connector is mounted automatically applies only the coil cleaner. --- 25.7. PVC cord does not apply. --- 25.14. not tested (the United States). --- 26.1. type vacuum cleaner should be Ⅰ, Ⅱ or Class Ⅲ; in some countries, is allowed to class 0 and class 0Ⅰ vacuum cleaner. --- Chapter 32 .. In addition to the Appendix AA IEC 60335-2-69, is responsible for labor protection of the national health department can make specific requirements (UK, Germany). --- AA. 22.101. wood, dust class M is H or a suitable (Germany). --- AA. 22.110. dust level M (according to the instructions for wood) and H appliances, basic filter should be below atmospheric pressure (Germany). GB 4706.88-2008/IEC 60335-2-69.1997 Household and similar electrical appliances - Safety Industrial and commercial driving force of the brush Particular requirements for wet and dry vacuum cleaners Range 1 GB 4706.1-1998 of this chapter except as follows, are applicable. Addition. This section applies to the electric vacuum cleaner includes a specially designated for wet and dry, with or without attachments wet suction, dry absorption or industrial and commercial Also in vertical suction equipment and appliances, for example for removing dust or the like with a suction device from the table and production equipment. Note. The commercial is for hotels, schools, hospitals, factories, shops and office use, rather than for general housework purposes. This portion is also suitable for collecting harmful dust, such as asbestos, or requires additional appliance liquid. This section also applies to the use of other forms of energy prime mover appliances, but its effect must be considered. modify. Note replaced by the following two lines of the original contents 3. --- GB 4706.7 applies for household appliances; --- Stationary centralized vacuum system settings; --- intend to use the appliance in locations where special conditions of a corrosive or explosive atmosphere (flammable gases or vapors) of. Addition. 101 NOTE. For battery-operated appliance, shall refer to IEC 60335-2-72.2 DefinitionsGB 4706.1-1998 of this chapter except for the following content, are applicable. 2.2.9 article replaced by the following. Normal operation of the vacuum motor, the input power Pm is calculated as follows. Pm = 0.5 (Pf + Pi) Where. PF --- nozzle and hose work gear on 3min provided by the manufacturer when the measured maximum input power in watts (W is); --- PI immediately after opening the nozzle work tool working 3min 20s of input power in the case of nozzle clogging watts Special (W). When clogging intake manifold, the gas flow used to ensure that any cooling of the motor a valve or the like inoperative. Pi and Pf measurement obtained in the following cases. the rated voltage adjusted supply voltage; if the threshold difference does not exceed the rated voltage range of the voltage range of the average Value of 10%, and the average nominal supply voltage range; if the tolerance range of the rated voltage exceeds the voltage range of the average 10% of the test Test case where the upper limit is adjusted to the rated voltage range of the supply voltage. Test fixture fashion with clean dust filter and a dust bag, with a container for collecting the liquid if it is, should be empty. If the appliance only with a Hoses used, then remove the removable nozzle and the hose to expand straight. If the hose with backup appliance is not used at work hose. Electric drive means is in operation, but not in contact with the ground or any other surface, or the means for closing the intake pipe of the same phase contact. The electrical load is equal to the average normal load Pr agitating means (e.g., an electric brush) was determined as follows. GB 4706.88-2008/IEC 60335-2-69.1997 --- agitation device operates in compliance with the GB/T 20291-2006 specified in 5.1.1.2 carpet; --- When using the apparatus in such a manner, the average load measured Pr; After setting apparatus according to the manufacturer's instructions, it should produce the highest load in the direction of movement of more than twice the distance of 5m. --- airflow motor and related work under the same conditions as the measurement Pf, namely. air flow without restrictions, measured after 3min get on; --- as recommended by the manufacturer, the device is adjusted to accommodate the height of the carpet nap; --- in the usual manner to be slow moving stirring means over the carpet, to avoid damage to the carpet. 2.101 Used to pump sewage from the appliance. If the sewage discharge pump typically operates as follows. Without tipping any sewage discharge pipe in the sewage outlet of the appliance, pump sewage, unless the discharge pipe permanently tipping the appliance. true The motor should be empty during a test operation, unless the interlock is installed to prevent operation of the two electric joint.3 general requirementsThe chapter of GB 4706.1-1998 is applicable. General Conditions Test 4 The chapter of GB 4706.1-1998 is applicable.5 VoidCategory 6 GB 4706.1-1998 of this chapter except for the following content, are applicable. 6.1 article replaced by the following. Protection against electric shock, a vacuum cleaner and accessory devices should belong to class Ⅰ, Ⅱ Ⅲ class or classes. Carrying appliance for use on the body should belong Ⅱ Ⅲ class or classes. Compliance is checked by inspection and relevant tests. 6.2 Addition. Appliance absorbent structure with the function of the cleaning liquid to be foamed and can not penetrate the motor or in contact with live parts. Appliances shall be at least IPX4 provisions of GB 4208-1993. Compliance is checked by inspection and test of 19.101.7 Marking and instructionsGB 4706.1-1998 of this chapter except for the following content, are applicable. 7.1 Addition. --- electric drive maximum rated input power nozzle should be marked on the appliance power outlet. Electric --- for wet vacuum cleaner nozzle should be marked with the driver. "Do not immersion." 7.9 Addition. And controlling the motor operation of the vacuum pump of the vacuum pump motor switch position is one to one. 7.12 Addition. The essence of the following content shall originate in the instructions for use. "The appliance is also suitable for commercial use, such as in hotels, schools, hospitals, factories, shops, offices, rental businesses in general is not suitable Home. " GB 4706.88-2008/IEC 60335-2-69.1997 If appropriate, the following warning should be included in the instructions for use. "Warning! This appliance is not suitable for collecting dangerous dust." "Warning! This appliance is for dry use, should not be used or stored outdoors in wet conditions." Any limitation on the use of the appliance socket should be clearly specified in the instructions for use. For wet suction apparatus, the instructions shall clearly states. "Warning! If foam/liquid spills, cut off the power immediately." Instructions appliance should include a water level control means for periodic cleaning and inspection instructions signs of damage done.8 Protection against access to live partsGB 4706.1-1998 of this chapter except for the following content, are applicable. 8.1 Addition. 101 Note. The dirty liquid collected wet suction appliance is considered conductive.9 start electric appliancesno request. Power input and current 10 The chapter of GB 4706.1-1998 is applicable. 11 fever GB 4706.1-1998 of this chapter except for the following content, are applicable. 11.3 Addition. If a thermocouple or another wiring installation tool must be removed, before and after the installation at the lowest possible load (eg. closed inlet port, brush The child does not contact with the ground, disengage the clutch, etc.) input power is measured to check whether the assembly has been completed correctly. 11.4 does not apply. 11.5 Addition. Pr heating test for normal load, the motor driving power brush can be simulated by a braking apparatus or otherwise. 11.6 does not apply. 12 Void Leakage current and electric strength at the operating temperature of 13 GB 4706.1-1998 of this chapter except for the following content, are applicable. 13.2 Addition. --- Class Ⅰ appliances simultaneously operating several motors 3.5mA 14 Void 15 Moisture resistance GB 4706.1-1998 of this chapter except for the following content, are applicable. 15.1.2 Addition. Wet suction appliance should be operated on a level surface cleaning liquid 10min predetermined 15.2 wet. In practice, it aspirates air containing a large amount of the suction motor is not overloaded; but still view the offered load in order to avoid overload. GB 4706.88-2008/IEC 60335-2-69.1997 15.2 article replaced by the following. Appliance with a liquid container, shall be constructed so that the liquid is too full, and unstable liquid overturned appliances and handheld appliances caused by overflow Out, it will not affect their electrical insulation. Compliance is checked by the following test. And a liquid container equipped with input jacks appliance equipped with a suitable connector and flexible cable or cord; to a liquid container and X-connected appliances specified in Table 11 with the minimum cross-sectional area of the cord test according to the delivery status of other appliances. The liquid container of the appliance with an aqueous solution containing about 1% NaCl is filled, then again equal to 15% of the capacity of the container, or 0.25L An aqueous solution of the same concentration, whichever is more than the amount, duration in 1min injected into the container. Container handheld appliances and utensils completely unstable after filled, close the lid, to tip it over from the most unfavorable position of normal use and stay in The location 5min, unless the appliance automatically returns to normal position. 101 Note. When the appliance was placed on a supporting surface 10 ° angle to the horizontal and in the most unfavorable position of normal use, which is dispensed into the liquid container manufacturer to use Description half the level specified height, if a 180N force is applied in the most unfavorable horizontal direction at the top, the appliance will tip over, These instruments are considered unstable. Appliance then subjected to the following tests. The nozzle is placed in a fixture sink, the sink surface and the bottom surface of the flat support means. 5mm above the bottom sink injection of Cleaning agents, this level remai......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 4706.88-2008_English be delivered?Answer: Upon your order, we will start to translate GB 4706.88-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 4706.88-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 4706.88-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |