Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB 23200.92-2016 English PDF

US$239.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 23200.92-2016: Food safety national standard -- Determination of pentachlorophenol residues in animal-derived foods by liquid chromatography-mass spectrometry
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 23200.92-2016239 Add to Cart 3 days Food safety national standard -- Determination of pentachlorophenol residues in animal-derived foods by liquid chromatography-mass spectrometry Valid

Similar standards

GB/T 38211   GB/T 18418   GB/T 18419   GB 23200.83   GB 23200.84   GB 23200.101   

Basic data

Standard ID: GB 23200.92-2016 (GB23200.92-2016)
Description (Translated English): Food safety national standard -- Determination of pentachlorophenol residues in animal-derived foods by liquid chromatography-mass spectrometry
Sector / Industry: National Standard
Classification of Chinese Standard: G25
Word Count Estimation: 12,167
Date of Issue: 2016-12-18
Date of Implementation: 2017-06-18
Older Standard (superseded by this standard): SN/T 2445-2010
Regulation (derived from): State Health Commission, Ministry of Agriculture, Food and Drug Administration Notice No. 16 of 2016
Issuing agency(ies): National Health and Family Planning Commission of the People's Republic of China, State Food and Drug Administration

GB 23200.92-2016: Food safety national standard -- Determination of pentachlorophenol residues in animal-derived foods by liquid chromatography-mass spectrometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Food safety national standard - Determination of pentachlorophenol residues in animal - derived foods by liquid chromatography - mass spectrometry National Standards of People's Republic of China GB Instead of SN/T 2445-2010 National standards for food safety Determination of Pentachlorophenol Residue in Animal Food Liquid chromatography - mass spectrometry National food safety standards- Determination of pentachlorophenol residue in animal-derived foods Liquid chromatography - mass spectrometry 2016-12-18 Release.2017-06-18 Implementation National Health and Family Planning Commission of the People 's Republic of China Issued by the Ministry of Agriculture of the People 's Republic of China State Administration of Food and Drug Administration

Foreword

This standard replaces SN/T 2445-2010 "Determination of Pentachlorophenol Residue in Foodstuffs for Import and Export Animal Liquid Chromatography-Mass Spectrometry/Mass Spectrometry law". Compared with SN/T 2445-2010, the main changes are as follows. - Standard text format is modified to national standard text format for food safety; - standard name and "import and export animal food" to "animal food"; - increase the "other food reference implementation" in the standard range. This standard replaced the previous version of the standard release. -SN/T 2445-2010. National standards for food safety Determination of pentachlorophenol residues in animal food by liquid chromatography - mass spectrometry

1 Scope

This standard specifies the preparation of pentachlorophenol residues in animal food and liquid chromatography-mass spectrometry. This standard applies to pig liver, pig kidney, pork, milk, fish, shrimp, crab and other animal food in the determination of pentachlorophenol residues. Other food Goods can refer to the implementation.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB 2763 National Standard for Food Safety - Maximum Residue Limit of Pesticides in Foodstuffs GB/T 6682 Analytical laboratory water specifications and test methods

3 principle

The pentachlorophenol residue in the sample was extracted with alkaline aqueous acetonitrile and purified by MAX solid phase extraction column. After concentration and volume, the residue was purified by liquid chromatography- Mass spectrometer detection and confirmation, external standard method quantitative.

4 reagents and materials

Unless otherwise stated, the reagents used were of analytical grade and water was a primary water specified in GB/T 6682. 4.1 Reagents 4.1.1 Methanol (CH3OH). Chromatographic Purification. 4.1.2 acetonitrile (CH3CN). pure chromatography. 4.1.3 Triethylamine (C6H15N). 4.1.4 Formic acid (HCOOH). Chromatographic pure. 4.1.5 Ammonium acetate (CH3COONH4). 4.1.6 Ammonia (NH3 · H2O). 4.2 solution preparation 4.2.1 acetonitrile - water solution (7 3). accurately measure 70mL acetonitrile and 30mL water, mix and shake. 4.2.2 5% triethylamine acetonitrile - water solution. accurately measure 50 mL of triethylamine, transferred into 1000 mL volumetric flask, with acetonitrile - water solution (7 3) Constant volume to the scale, mixed evenly. 4.2.3 5% ammonia solution. the amount of.200mL concentrated ammonia (25%), transferred into the 1000 mL volumetric flask, water volume to the scale, mixed Evenly. 4.2.4 4% formic acid methanol solution. the amount of 10 mL of formic acid, transferred into the 250 mL volumetric flask, with methanol volume to the scale, mixed evenly. 4.2.5 2% formic acid methanol aqueous solution. take a certain amount of 4% formic acid methanol solution and water volume mixed evenly. 4.2.6 5 mmol/L ammonium acetate aqueous solution. accurately weighed 0.3854 g ammonium acetate, dissolved in water, transferred to 1000 mL volumetric flask, set Capacity to scale, mixed evenly. 4.3 standards 4.3.1 Pentachlorophenol sodium salt (CAS No.. 131-52-2). purity ≥94.5%, or equivalent. 4.4 standard solution preparation 4.4.1 Standard stock solution (200mg/L). Weigh the equivalent of 10 mg (accurate to 0.1 mg) pentachlorophenol standard, with a The alcohol was dissolved and set in a 50 mL brown volumetric flask. This stock solution can be stored for up to 12 months under -18 ° C. 4.4.2 standard working solution. standard working solution according to the need before use with blank sample matrix solution preparation. Store in 4 ℃ refrigerator. 4.5 Materials 4.5.1 Solid phase extraction (SPE) column. Oasis MAX, 60 mg, 3 mL, or equivalent. Use 5 mL of methanol and 5 mL of water before use activation. 4.5.2 Nitrogen. Purity ≥99.99%.

5 instruments and equipment

5.1 Liquid Chromatography Series Quadrupole Mass Spectrometer. Distribution Spray Ion Source. 5.2 Analysis of balance. 0.01 g and 0.0001 g. 5.3 vortex mixer. 5.4 Centrifuge, 5 000 r/min. 5.5 Solid phase extraction vacuum device. 5.6 mechanical vacuum pump. 5.7 Tissue crusher. 5.8 Homogenizer. 5.9 Ultrasonic instrument. 5.10 blowing nitrogen enrichment instrument.

6 Preparation and storage of samples

6.1 Preparation of the sample During the sample preparation operation, it is necessary to prevent the sample from being contaminated or the change in the content of the residue. 6.1.1 animal muscle, liver, kidney, fish, shrimp and crab A typical sample of about 500 g was taken from all the samples taken and mashed evenly in a tissue masher and divided into two portions. Into a clean container, sealed and marked with a mark. 6.1.2 Milk samples A typical sample of about 500 g was taken from all the samples taken and mixed thoroughly and divided into two portions, packed in a clean container, Seal, and mark the mark. Note. The above sample sampling site according to GB 2763 Appendix A implementation. 6.2 Sample storage Samples were stored at -18 ° C or lower.

7 Analysis steps

7.1 Extraction 7.1.1 Muscle, fish, liver, kidney, shrimp and crab Weigh the homogeneous sample 2 g (accurate to 0.01 g), placed in 10 mL screw cap polypropylene centrifuge tube, add 6 mL of 5% triethylamine Acetonitrile - aqueous solution. Muscle and fish samples were homogenized for 2 min; liver, kidney, shrimp and crab samples were mixed for 1 min and extracted by ultrasonic for 5 min. 3 000 r/min centrifugation 5 min, the supernatant was collected in a graduated centrifuge tube. The residue after centrifugation was treated with about 6 mL of 5% triethylamine in acetonitrile- Aqueous solution The above extraction step was repeated once, and the supernatant was combined and mixed. 7.1.2 milk Weigh the homogeneous sample 2 g (accurate to 0.01 g), placed in a 10 mL graduated screw cap polypropylene centrifuge tube, add 10 mL 5% tri Amine in acetonitrile - aqueous solution, vortex mixed for 1 min, ultrasonic extraction 5 min, 5 000 r/min centrifugation 5 min, collecting supernatant in a scale Centrifuge tube. 7.2 Solid phase extraction purification The resulting solution from 7.1 was transferred to a pre-treated MAX solid phase extraction column to pass the solid solution at a rate of about 1 drop/sec. Phase extraction column, discard the effluent. Followed by elution with 5 mL of 5% aqueous ammonia solution, 5 mL of methanol, 5 mL of 2% formic acid in methanol-water After the lotion is completely passed through the column, the effluent is discarded and the solid phase extraction column is evacuated with a vacuum pump for more than 5 min. Washed with 4 mL of 4% formic acid in methanol The eluate was collected with a clean 15 mL scale tube and concentrated at 0 ° C in a water bath at 40 ° C to 1 mL. The mixture was fixed to 2 mL with water and mixed. Dissolve The solution was filtered through a 0.22 μm organic filter for analysis. 7.3 Instrument reference conditions 7.3.1 Liquid Chromatographic Reference Conditions A) Column. ZORBAX Eclipse XDB-C18, 1.8 μm, 50 x 2.1 mm (id), or equivalent; B) mobile phase. methanol 5mmol/L ammonium acetate solution, gradient elution (gradient time schedule in Table 1); C) Flow rate. 250 μL/min; D) Column temperature. 30 ° C; E) Injection volume. 30 μL. Table 1 Gradient elution conditions for liquid chromatography Time (min) Flow rate (L/min) 5mmol/L Ammonium acetate solution (%) Methanol (%) 0.00 250 60 40 1.00 250 0 100 7.00 250 0 100 7.50 250 60 40 12.00 250 60 40 7.3.2 Mass spectrometry reference conditions A) ionization mode. electrospray ionization anion mode (ESI-); B) Mass spectrometry scanning mode. Multiple reaction monitoring (MRM); C) Resolution. Unit resolution; D) See Appendix A for other reference mass spectrometric conditions. E) Quantitative ion pair. 262.7 > 262.7, qualitative ion pair. 264.7 > 264.7,266.7 > 266.7,268.7 > 268.7. 7.4 determination 7.4.1 Qualitative determination The MRM was monitored by 4 pairs of parent ions. Under the same experimental conditions, the retention time of the test substance in the sample was compared with that of the matrix standard solution Of the retention time deviation within ± 2.5%; and the sample of each component qualitative ion relative abundance and concentration close to the matrix mixed standard working dissolved The relative abundance of the corresponding qualitative ions in the liquid, the deviation does not exceed the range specified in Table 2, it can be determined that there is a corresponding To be measured. Table 2 The maximum allowable deviation of relative ion abundance when qualitative confirmation Relative ion abundance > 50% > 20% to 50% > 10% to 20% ≤10% Maximum permissible deviation ± 20% ± 25% ± 30% ± 50% 7.4.2 Quantitative determination In the best working conditions of the instrument, the standard solution of the mixed working solution of the matrix, with the peak area as the ordinate, the matrix mixed standard working solution Liquid concentration for the abscissa to draw the standard working curve, with the standard working curve of the sample quantitative, the sample solution to be measured the response value should be In the linear range of the instrument determination. The multi-reaction monitoring (MRM) chromatogram of pentachlorophenol reference material is shown in Figure B.1 in Appendix B. 7.5 blank experiment In addition to the sample, according to the above determination steps.

8 results are calculated and expressed

The amount of pentachlorophenol residues was calculated according to formula (1) by external standard method. 1000  Vc X (1) Where. X-the remaining amount of the test component in micrograms per kilogram, μg/kg; C - the concentration of the solution to be measured from the standard operating curve in micrograms per liter, μg/L; V-sample solution final volume, in milliliters, mL; M - the mass of the sample represented by the final sample solution, in grams, g. Note. The result of the calculation shall be deducted from the blank value. The result of the measurement shall be expressed as the arithmetic mean of the parallel measurement, and two valid digits shall be retained.

9 precision

9.1 The ratio of the absolute difference between the two independent determinations obtained under reproducibility and its arithmetic mean (percentage) shall be in accordance with Appendix D requirements. 9.2 The ratio of the absolute difference between the two independent determinations obtained under reproducibility and its arithmetic mean (percentage) shall be in accordance with Appendix E requirements. 10% limit and recovery rate 10.1 Quantitation limits The quantification limit for pentachlorophenol was 1.0 μg/kg. 10.2 Recovery rate When adding levels of 1.00, 2.00, 4.00 μg/kg, the back of pentachlorophenol in pork, liver, kidney, milk, fish, shrimp and crab See Appendix C for yield data.

Appendix A

(Informative) Reference to mass spectrometry conditions A) Air curtain gas pressure (CUR). 20.00 psi (nitrogen); B) electrospray voltage (IS). - 4 500 V; C) ion source temperature (TEM). 550 ° C; D) atomization gas pressure 35 psi (nitrogen); E) Auxiliary gas pressure 60 psi (nitrogen); F) Other mass spectral parameters are shown in Table A1. Schedule A1 is the primary reference to mass spectrometry parameters Compounds Mother ion (M/z) Ion (M/z) Dwell time (Msec) DP EP CE (EV) CXP Pentachlorophenol 262.7 * 262.7 * 100 -75 -10 -23 -5 264.7 264.7 100 266.7 266.7 100 268.7 268.7 100 Note. The ions in Table A1 with * ions for the quantitative ions; for different mass spectrometry equipment, instrument parameters may be different, should be determined before the mass spectrometry parameters to the most good. Non-commercial statement. The reference mass spectrometry conditions listed in Appendix A are performed on the API4000QTrap LC/MS, where the test instrument model is only listed For reference, does not involve commercial purposes, encourage standard users to try different manufacturers or models of equipment.

Appendix B

(Informative) Standard multi-reaction monitoring (MRM) chromatograms Figure B1 Multiple reaction monitoring (MRM) chromatograms of 5.0 μg/L pentachlorophenol

Appendix C

(Informative) The recovery of pentachlorophenol in different substrates Table C.1 Recovery of pentachlorophenol in different substrates Material species Add concentration (Μg/kg) Recovery rate range (%) Pork Pig Pig Pork Kidney Milk Fish Meat Shrimp and Crab Pentachlorophenol 1.0 94.9-109 75.8-104 88.0-108 79.0-98.7 80.0-94.1 79.2-104 66.7-94.1 2.0 82.1-108 81.0-97.5 80.6-103 87.1-98.5 78.4-90.5 77.4-89.6 77.0-99.5 4.0 91.6-96.7 83.4-90.2 74.7-89.3 92.8-99.0 79.8-92.6 76.8-87.9 83.0-97.2

Appendix D

(Normative appendix) Laboratory repeatability requirements Table D.1 Laboratory repeatability requirements Measured component content Mg/kg Precision 0.001 36 > 0.01 > 1 14

Appendix E

(Normative appendix) Inter-laboratory reproducibility requirements Table E.1 Inter-laboratory reproducibility requirements Measured component content Mg/kg Precision 0.001 54 > 0.01 > 1 19
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 23200.92-2016_English be delivered?

Answer: Upon your order, we will start to translate GB 23200.92-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 23200.92-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB 23200.92-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.