GB 19880-2024 English PDFUS$679.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 19880-2024: Manual fire call points Status: Valid GB 19880: Historical versions
Basic dataStandard ID: GB 19880-2024 (GB19880-2024)Description (Translated English): Manual fire call points Sector / Industry: National Standard Classification of Chinese Standard: C81 Classification of International Standard: 13.220.20 Word Count Estimation: 34,322 Date of Issue: 2024-11-28 Date of Implementation: 2025-12-01 Older Standard (superseded by this standard): GB 19880-2005 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB 19880-2024: Manual fire call points---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.ICS 13.220.20 CCSC81 National Standard of the People's Republic of China Replaces GB 19880-2005 Manual fire alarm button 2025-12-01 Implementation State Administration for Market Regulation The National Standardization Administration issued Table of ContentsPreface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Categories 2 4.1 Classification by applicable places 2 4.2 Classification by recoverability 2 5 Requirement 2 5.1 General 2 5.2 General requirements 3 5.3 Main components (devices) 5 5.4 Basic functions 6 5.5 Basic performance 6 5.6 Test performance 7 6 Test methods 10 6.1 General 10 6.2 Appearance 12 6.3 Structure 12 6.4 Size 12 6.5 Surface Color 12 6.6 Graphic symbols and text 12 6.7 Main components (devices) 12 6.8 Labels and instructions for use 13 6.9 Alarm function test 13 6.10 Operational component recovery function test 13 6.11 Reset function test 13 6.12 Non-operation performance test 13 6.13 Action performance test 13 6.14 Reliability performance test 13 6.15 Power supply parameter fluctuation performance test 14 6.16 High temperature (operation) test 14 6.17 Low temperature (operation) test 14 6.18 Cyclic damp heat (operation) test 14 6.19 High temperature (durability) test 15 6.20 Steady-state heat and humidity (durability) test 15 6.21 Sulfur dioxide (SO2) corrosion (durability) test 15 6.22 Salt spray test 16 6.23 Impact (operation) test 16 6.24 Collision (operation) test 16 6.25 Vibration (sinusoidal) (operating) test 18 6.26 Vibration (sinusoidal) (endurance) test 18 6.27 Electrostatic discharge immunity test 18 6.28 Radio frequency electromagnetic field radiation immunity test 18 6.29 Radio frequency field induced conducted disturbance immunity test 19 6.30 Electrical fast transient pulse group immunity test 19 6.31 Surge (impact) immunity test 19 6.32 Power frequency magnetic field immunity test 19 6.33 Enclosure protection level test 20 6.34 Dust pollution test 20 6.35 Drop test 20 6.36 Fluorescent UV lamp aging (operation) test 20 7 Inspection Rules 21 7.1 Factory Inspection 21 7.2 Type inspection 21 8 Sign 21 8.1 Product Labelling 21 8.2 Quality inspection mark 22 8.3 Sign durability 22 9 User Manual 22 Appendix A (Normative) Non-operating performance test device 23 Appendix B (Normative) Action Performance Test Device 24 Appendix C (Normative) Dust environment simulation test device and dust 25 Appendix D (Normative) Drop test device 27 Appendix E (Normative) Fluorescent UV Aging Test Device 28 E.1 Test chamber 28 E.2 Light source 28 E.3 Radiometer 28 E.4 Blackboard thermometer 28 E.5 Condensation 28 E.6 Water spray 28 E.7 Sample rack 28ForewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB 19880-2005 "Manual fire alarm button". Compared with GB 19880-2005, except for structural adjustments and editorial In addition to the modifications, the main technical changes are as follows. a) Added terms and definitions (see Chapter 3); b) Added classification (see Chapter 4); c) Changed the structural requirements (see 5.2.2, 3.7 of the.2005 edition); d) The size requirements have been changed (see 5.2.3, 3.7.2.2 of the.2005 edition); e) The requirements for graphic symbols and text have been changed (see 5.2.5, 3.7.3 of the.2005 edition); f) Added alarm function requirements (see 5.4.1); g) Added the requirements for the operating component recovery function (see 5.4.2); h) Added reset function requirements (see 5.4.3); i) Added salt spray test performance requirements (see 5.6.1); j) The technical parameters of the conducted disturbance immunity test induced by radio frequency fields have been changed (see 5.6.3, 4.19 of the.2005 edition); k) Added protection level test performance requirements (see 5.6.4); l) Added dust pollution resistance requirements (see 5.6.5); m) Added drop resistance requirements (see 5.6.6); n) Added the requirements for resistance to fluorescent UV lamp aging performance (see 5.6.7); o) Added test items and test methods such as alarm function test and operating component recovery function test (see Chapter 6); p) The rain test was deleted (see 4.22 of the.2005 edition); q) Added the marking durability test method (see 8.3); r) Added dust environment simulation test device and dust (see Appendix C); s) Added drop test device (see Appendix D); t) Added fluorescent ultraviolet aging test device (see Appendix E). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed and coordinated by the National Fire and Rescue Administration. This document was first published in.2005 and this is the first revision. Manual fire alarm button1 ScopeThis document specifies the classification, requirements, inspection rules, marking and instructions for use of manual fire alarm buttons, and describes the corresponding tests method. This document applies to the design, manufacture and inspection of manual fire alarm pushbutton products used in industrial and civil buildings.2 Normative referencesThe contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB (/T) 3836 (all parts) Explosive atmospheres GB/T 4208-2017 Enclosure protection degree (IP code) GB/T 9969 General principles for instructions for use of industrial products GB 12978 Inspection Rules for Fire Protection Electronic Products GB/T 16838 Environmental test methods and severity levels for fire protection electronic products GB/T 17626.2 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test GB/T 17626.3 Electromagnetic compatibility test and measurement technology Part 3.Radio frequency electromagnetic field radiation immunity test GB/T 17626.4 Electromagnetic compatibility test and measurement technology Electrical fast transient pulse group immunity test GB/T 17626.5 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test GB/T 17626.6 Electromagnetic compatibility test and measurement technology - Immunity to conducted disturbances induced by radio frequency fields GB/T 17626.8 Electromagnetic compatibility test and measurement technology Power frequency magnetic field immunity test GB/T 28957.1-2023 Test dust for filter evaluation on road vehicles Part 1.Silicon oxide test dust3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 Manual fire alarm buttonsmanualfirecalpoints A trigger device for manually sending out a fire alarm signal. 3.2 Manual fire alarm button works at rated voltage, operating components and starting parts are not in action, and there is no alarm or fault signal. state. 3.3 Alarm status alarmcondition The state of the manual fire alarm button's operating components and starting parts after a fire alarm signal is issued. 3.4 Front panel The area visible from the front of the manual fire alarm button excluding the operating panel. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 19880-2024_English be delivered?Answer: Upon your order, we will start to translate GB 19880-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 19880-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB 19880-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB 19880-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19880-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |