GB/T 19214.1-2023 English PDFUS$1779.00 · In stock
Delivery: <= 9 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19214.1-2023: Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses Status: Valid GB/T 19214.1: Historical versions
Basic dataStandard ID: GB/T 19214.1-2023 (GB/T19214.1-2023)Description (Translated English): Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K31 Classification of International Standard: 29.120.50 Word Count Estimation: 89,855 Date of Issue: 2023-09-07 Date of Implementation: 2024-04-01 Older Standard (superseded by this standard): GB/T 19214-2008 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 19214.1-2023: Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. ICS 29.120.50 CCSK31 National Standards of People's Republic of China Replace GB/T 19214-2008 Electrical accessories residual current monitor (RCM) Part 1.Household and similar use surplus Current monitor (IEC 62020-1.2020,IDT) Published on 2023-09-07 2024-04-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee Table of contentsPreface V Introduction VI 1 Scope 1 2 Normative reference documents 1 3 Terms and Definitions 3 4 Category 5 4.1 Divide into 5 points according to the action method 4.2 Divide into 5 according to device type 4.3 Score 5 points based on current loop number 4.4 Divide into 5 points based on the ability to adjust the residual operating current 4.5 Score 5 points based on the possibility of adjusting the delay 4.6 Points 5 based on protection against external influences 4.7 Divided into 5 according to installation method 4.8 Divided into 5 according to wiring method 4.9 Divided into 6 according to load wire connection type 4.10 Divide into 6 according to fault indicating device 4.11 According to the ability to distinguish the direction of residual current on the power side and load side, it is divided into 6 points 4.12 Divided into 6 according to power supply system 4.13 Divide 6 according to the monitored residual current type 4.14 Divided into 6 according to the residual current detection method 5 Characteristics of RCM 6 5.1 Feature Summary 6 5.2 Ratings and other characteristics7 5.3 Standard and preferred values 8 5.4 Cooperation with short circuit protective device (SCPD) (only applicable to RCM classified according to 4.9.2) 10 6 Logo and other product data10 7 Standard operating conditions for use and installation12 7.1 Standard conditions 12 7.2 Installation conditions 12 8 Structural and operational requirements 12 8.1 Mechanical design 12 8.2 Protection against electric shock16 8.3 Dielectric properties 17 8.4 Temperature rise 17 8.5 Action characteristics 17 8.6 Direction judgment 17 8.7 Operating life 18 8.8 Performance under short-circuit current18 8.9 Mechanical impact resistance18 8.10 Heat resistance18 8.11 Resistance to abnormal heat generation and flame resistance18 8.12 Test device 18 8.13 RCM operates correctly within the power supply voltage range 19 8.14 When the main circuit is over-current, the working status of RCM19 8.15 RCM’s performance in preventing malfunction under the action of surge current generated by impulse voltage19 8.16 When the ground fault current contains a DC component, the working condition of the RCM19 8.17 Reliability19 8.18 Electromagnetic compatibility (EMC) 19 8.19 Connection of external current transformer (CT) 19 8.20 RCM response to temporary overvoltage on the low-voltage side caused by high-voltage side fault19 9 Trial 20 9.1 General requirements 20 9.2 Test conditions 20 9.3 Marking durability test 21 9.4 Reliability testing of screws, current-carrying parts and connections21 9.5 Reliability test of terminal blocks connected to external conductors 22 9.6 Verification of electric shock protection 23 9.7 Dielectric property test 24 9.8 Temperature rise test 28 9.9 Verify action characteristics 28 9.10 Verification of operating life 30 9.11 Verification of short-circuit withstand capability31 9.12 Verification of mechanical impact resistance35 9.13 Heat resistance test 37 9.14 Abnormal heating resistance and flame resistance test 37 9.15 Verification of operation of the test device at rated voltage limits38 9.16 Verify the non-operating current limit value in case of overcurrent38 9.17 Verify the performance against malfunction under the action of surge current caused by impulse voltage 39 9.18 Empty 39 9.19 Verify the correct operation when the residual current contains a DC component39 9.20 Verify Reliability 44 9.21 Verify the anti-aging performance of electronic components 46 9.22 Verification of electromagnetic compatibility (EMC) requirements 46 9.23 RCM response to temporary overvoltage on the low-voltage side caused by high-voltage side fault 48 9.24 Anti-rust test 48 Appendix A (Normative) Test procedures and number of test specimens to verify compliance with this document 76 A.1 Summary 76 A.2 Test procedure 76 A.3 Number of test samples submitted for all test procedures 77 A.4 When a series of RCMs with the same basic design and structure are submitted for testing at the same time, the number of specimens for the simplified test procedure is 77 Appendix B (Normative) Determination of electrical clearances and creepage distances 80 Reference 82ForewordThis document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document is Part 1 of GB/T 19214 "Residual Current Monitor (RCM) for Electrical Accessories". GB/T 19214 has been released The following sections are included. ---Part 1.Residual current monitors for household and similar purposes. This document replaces GB/T 19214-2008 "Residual current monitors for electrical accessories for household and similar purposes". This document is related to Compared with GB/T 19214-2008, in addition to structural adjustments and editorial changes, the main technical changes are as follows. ---Added the classification, action characteristics and verification requirements of Type F and Type B RCM (see 4.13, 5.2.6.3, 5.2.6.4 and 9.19.3); ---In the action characteristics test, the requirement to conduct separate tests at the TN and TT positions is deleted (see 9.9.2, 9.9.4 and Figure 3). This document is equivalent to IEC 62020-1.2020 "Residual current monitor (RCM) for electrical accessories - Part 1.Household and similar Purpose Residual Current Monitor". This document has made the following minimal editorial changes. ---In the action characteristic test and in Figure 3, the TN and TT position descriptions missing from the original text have been deleted. --- Add a note in 9.11.2.1 to give reference information for the silver wire diameter, τ't and τp values at 10000A. Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document is proposed by the China Electrical Equipment Industry Association. This document is under the jurisdiction of the National Low Voltage Electrical Equipment Standardization Technical Committee (SAC/TC189). This document was drafted by. Shanghai Electrical Apparatus Research Institute, Shanghai Liangxin Electric Co., Ltd., Shanghai Noyak Electric Co., Ltd., China Shanshi Kaipu Electric Co., Ltd., Zhejiang Tianzheng Electric Co., Ltd., Suzhou Yieryi Electrical Manufacturing Co., Ltd., Schneider Electric (China (China) Co., Ltd. Shanghai Branch, Shanghai Siemens Line Protection System Co., Ltd., Delixi Electric Co., Ltd., Qingdao Dingxin Communications Co., Ltd. Co., Ltd., Beijing ABB Low Voltage Electrical Appliances Co., Ltd., Zhejiang Chint Electric Co., Ltd., Hangzhou Electric Power Equipment Manufacturing Co., Ltd. Yuhang Qunli Complete Electrical Manufacturing Branch, Yuyao Jiarong Electronics and Electrical Co., Ltd., Meigao Electric Technology Co., Ltd., Zhejiang Chuangqi Electric Co., Ltd. Company, Xiamen Zhentaicheng Technology Co., Ltd., Zhuhai Painuo Technology Co., Ltd. The main drafters of this document. Wang Yuxuan, Yi Ying, Xie Jianbo, Ge Weijun, Zou Jianhua, Liu Chao, Li Chengli, Li Chanjuan, Chen Jia, Bai Jianshe, Wang Jianhua, Zhang Yanhui, Li Jie, Miao Yufeng, Qian Jiaqan, Xue Jiewei, Jiang Song, Cai Chongsheng, Zhang Yingteng. The previous versions of this document and the documents it replaces are as follows. ---First published as GB 19214-2003 in.2003, first revised in.2008; ---This is the second revision.IntroductionResidual current monitors are used to monitor residual current in installations and are generated between live parts and exposed conductive parts or ground. An electrical appliance that sends an alarm signal when the residual current exceeds a predetermined value. GB/T 19214 "Residual Current Monitor (RCM) for Electrical Accessories" refers to A series of standards for residual current monitor products is planned to consist of 2 parts. ---Part 1.Residual current monitors for household and similar purposes. The purpose is to specify the performance of RCM for household and similar purposes requirements and test methods and other product-related requirements. ---Part 2.Residual current monitors for industrial use up to 1000VAC. The purpose is to provide for industrial use of RCM Product-related requirements such as performance requirements and test methods. Electrical accessories residual current monitor (RCM) Part 1.Household and similar use surplus Current monitor1 ScopeThis document applies to residual current for household and similar purposes with a rated voltage not exceeding AC 440V and a rated current not exceeding 125A. monitor. This document specifies the classification, characteristics, technical requirements and testing of RCM. Note 1.A standard (IEC 62020-2) for residual current monitors whose rated operating voltage and rated voltage of the circuit being monitored exceeds 440V AC is under consideration. RCM is used to monitor the residual current in the installation and the residual current generated between live parts and exposed conductive parts or ground. An alarm signal is issued when the predetermined value is exceeded. RCM detects suddenly applied or slowly rising residual current in AC circuits (such as AC residual current, pulsating DC residual current current, smooth DC residual current). Note 2.RCM for DC systems is under consideration. This document is applicable to functions that can simultaneously detect residual current, compare the residual current value with the residual operating current value, and the current A monitor that provides a specified alarm signal when the residual current exceeds the residual operating current value. The technical requirements of this document apply to normal environmental conditions (see 7.1). For RCMs used in locations with harsh environmental conditions, it may be necessary to Additional technical requirements are required. RCM is suitable for environments with pollution level 2 and overvoltage category III. For environments with higher pollution levels, it is advisable to use Protection grade casing. RCM conforming to this document applies to TN, TT and IT systems. The RCM involved in this document cannot be used to protect electrical appliances. This document does not cover internal battery powered RCMs. This document does not cover insulation monitors (IMD), which fall within the scope of IEC 61557-8. Note 3.The difference between RCM and IMD is that the monitoring function of RCM is passive and can only respond to the unbalanced fault current of the monitored device. IMD monitoring And the measurement function is active, it can measure the balanced and unbalanced insulation resistance or impedance in the device (see IEC 61557-8).2 Normative reference documentsThe contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document. GB/T 2423.4-2008 Environmental testing of electrical and electronic products Part 2.Test method test Db alternating damp heat (12h 12h cycle)(IEC 60068-2-30.2005,IDT) GB/T 5169.11-2017 Fire hazard test for electrical and electronic products Part 11.Glow wire/hot wire basic test method Glow wire flammability test method (GWEPT) for products (IEC 60695-2-11.2014, IDT) GB/T 16935.1-2023 Insulation coordination of equipment in low-voltage power supply systems Part 1.Principles, requirements and tests (IEC 60664-1.2020,IDT) Note. There is no technical difference between the quoted content of GB/T 16935.1-2023 and the quoted content of IEC 60664-1.2007. IEC 60038 standard voltages Note. GB/T 156-2017 standard voltage (IEC 60038.2009, MOD) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19214.1-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 19214.1-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 6 ~ 9 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 19214.1-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19214.1-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 19214.1-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19214.1-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |