Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB 19212.6-2013 English PDF

US$389.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 19212.6-2013: [GB/T 19212.6-2013] Safety of transformers, reactors, power supply units and combinations thereof -- Part 6: Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units
Status: Valid

GB 19212.6: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 19212.6-2013389 Add to Cart 4 days [GB/T 19212.6-2013] Safety of transformers, reactors, power supply units and combinations thereof -- Part 6: Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units Valid
GB 19212.6-2006439 Add to Cart 4 days Safety of power transformers, power supply units and similar -- Part 6: Particular requirements for shaver transformers and shaver supply units Obsolete

Similar standards

GB/T 19212.5   GB/T 10228   GB/T 8286   GB/T 19212.2   GB/T 19212.14   GB/T 19212.1   

Basic data

Standard ID: GB 19212.6-2013 (GB19212.6-2013)
Description (Translated English): [GB/T 19212.6-2013] Safety of transformers, reactors, power supply units and combinations thereof -- Part 6: Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units
Sector / Industry: National Standard
Classification of Chinese Standard: K41
Classification of International Standard: 29.180
Word Count Estimation: 15,128
Older Standard (superseded by this standard): GB 19212.6-2006
Quoted Standard: GB 19212.1-2008; IEC 60068-2-62-1-1991; IEC 60670-1; IEC 60670-21; IEC 60670-22; IEC 60670-23; IEC 60670-24
Adopted Standard: IEC 61558-2-5-2010, IDT
Regulation (derived from): National Standards Bulletin No. 25 of 2013
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the safety requirements for shaver transformers, power supply units built shaver transformers and shaver supply unit. With electronic circuits shaver transformers are also included in this standard. Unless otherwise specified, the

GB 19212.6-2013: [GB/T 19212.6-2013] Safety of transformers, reactors, power supply units and combinations thereof -- Part 6: Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety of transformers, reactors, power supply units and combinations thereof.Part 6. Particular requirements and test for transformer for shavers, power supply units for shavers snd shaver supply units ICS 29.180 K41 National Standards of People's Republic of China Replacing GB 19212.6-2006 Safety transformers, reactors, power supply units and combinations thereof Part 6. shaver transformers, shaver Power supply means and power supply means of the shaver Particular requirements and tests Safetyoftransformers, reactors, powersupplyunitsandcombinationsthereof- Part 6. Particularrequirementsandtestfortransformerforshavers, (IEC 61558-2-5.2010, Safetyoftransformers, reactors, powersupplyunitsand combinationsthereof-Part 2-5. Particularrequirementsandtestfortransformer forshavers, powersupplyunitsforshaversandshaversupplyunits, IDT) Issued on. 2014-11-14 2013-12-17 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 2 General requirements 5 General notes 2 Rating 2 6 7 Category 2 8 Marking and other information 3 9 Protection against electric shock 3 10 change the input voltage setpoint 3 11 load output voltage and output current 3 12 no-load output voltage of 3 13 short-circuit voltage 4 14 fever 4 15 short-circuit and overload protection 4 16 Mechanical strength 4 17 to prevent dust, solid objects and moisture into the harmful Protection 5 18 insulation resistance, dielectric strength and leakage current 5 19 Structure 5 20 Component 6 21 Internal wiring 7 22 Supply connection and other external flexible cable or cord 7 23 Terminals for external conductors 7 24 protection grounding device 7 25 Screws and connections 7 26 creepage distances, clearances and distances through insulation 7 27 heat, fire and electrical resistance mark of 8 28 rust 8 Appendix 9 Reference 10 101 meter drop height 5

Foreword

All technical content in this section is mandatory. GB 19212 "of power transformers, power supplies, reactors and similar products -" 1) is divided into several parts. 1) This series of standards, some parts are under "power transformers, power supplies, reactors and similar products," the title, some parts in the "Supply Voltage And to 1100kV of transformers, reactors, power supply units and similar products "under the heading, some parts in the" transformers, reactors, electrical Under the source device and the combination is safe, "the title, the title of this series of standards may be modified in future releases. Part 1. General requirements and tests; Part 2. Particular requirements and general purpose test transformer isolated and built separate transformer power supply; Part 3. Specific requirements and test transformer control and built-in control transformer power supply; Part 4. Gas and oil burner ignition transformers for special requirements; Part 5. Specific requirements and test isolation transformer isolation and built-in transformer power supply device; Part 6. shaver transformer, and shaver shaver supply units power supply unit Particular requirements and tests; Part 7. Particular requirements and tests for safety isolating transformers and built-in safety isolating transformer power supply device; Part 8. Particular requirements for transformers for toys and power supplies and test; Part 9. Particular requirements for bell and bell transformers; Part 10. Class Ⅲ portable tungsten transformer and power devices - Particular requirements and tests; Part 13. Particular requirements for constant voltage transformers; Part 14. Particular requirements for auto transformers and autotransformers built power supply device; Part 16. supply of medical locations Particular requirements for isolating transformers; Part 17. switched-mode power supply units and switch-mode power supply unit with the special requirements for transformers and tests; Part 20. Particular requirements for interference attenuation transformers; Part 21. Small reactors Particular requirements and tests; Part 24. Particular requirements for transformers for construction sites. Other parts are under consideration. This is Part 6 GB 19212's. This is part of the GB 19212.1-2008 developed on the basis of this part of the need and GB 19212.1-2008 and No. 1 in conjunction with amendments. This part is the GB 19212.1-2008 corresponding chapter, article be Complement Charge and modified so that the content of GB 19212.1-2008 conversion based content portions. This new section for the GB 19212.1-2008 Additions numbered starting from 101. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB 19212.6-2006 "Safety - Part 6 power transformers, power supply units and similar products. shaving with change Particular requirements for pressure and shaver supply units. " This section compared with GB 19212.6-2006, the main technical changes are as follows. --- Standard name changed to "transformers, reactors, power supply units and combinations thereof - Safety - Part 6. shaver transformers, shaving Particular requirements and tests "blade shaver with power supply unit and power supply means; --- Amend the provisions of Chapter 1 Scope (see Chapter 1); --- Modify the term "shaver transformers" and the definition of "razor-powered device" (see 3.1.101 and 3.1.102); --- Remove the rated output voltage specified preferred value range (see 2006 edition of 6.101); --- Increased provision independent transformer no-load output voltage limit (see 12.101); --- Remove the GB 19212.1-2008 Chapter 18 provisions do not apply (see the 2006 edition of the 18.2 and 18.3); --- Amend the provisions of the structure (see Chapter 19); --- Removed Appendices C and D (see the 2006 edition of Appendices C and D). This section uses the translation method identical with IEC 61558-2-5.2010 "transformers, reactors, power supply units and combinations Safety Part 2-5. shaver transformer, and shaver shaver supply units power supply unit Particular requirements and tests. " Consistency correspondence between this part of international documents and normative references of our files are as follows. GB 17466 (all parts) for household and similar fixed electrical installations boxes and enclosures for electrical accessories [IEC 60670 (al parts), IDT] This part made the following editorial changes. --- Standard name changed to "transformers, reactors, power supply units and combinations thereof - Safety - Part 6. shaver transformers, shaving Particular requirements and tests "blade shaver with power supply unit and power supply means; --- Chapter 2, "Normative references" with "GB 19212.1-2008 amendments No. 1" instead of "IEC 61558-1.2005". Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Small power transformers, reactors, power supply units and similar products Standardization Technical Committee (SAC/TC418) Centralized. This section is drafted. Shenyang Transformer Research Institute Co., Ltd., Shanghai Quality Supervision, Inspection Technology Research Institute, National Broadcasting electricity Depending on the product quality supervision and inspection center, Shenzhen Institute of Electrical Sciences, Chinese Academy of household appliances, high-Hui Electronics Co., Ltd. Tianjin Optical. The main drafters of this section. Lin Ran, Yu Yimin, Zhang Yafang, Xiaomin Ying, SUN Xuan, Li Dongbo. This part of the standard replaces the previous editions as. --- GB 19212.6-2006. Safety transformers, reactors, power supply units and combinations thereof Part 6. shaver transformers, shaver Power supply means and power supply means of the shaver Particular requirements and tests

1 Scope

GB 19212.1-2008 this chapter is replaced by the following. GB This section 19212 specifies the shaver transformers, power supply units built shaver transformers and shaver supply unit Safety requirements. With electronic circuits shaver transformers are also included in this section. Note 1. Safety requirements including electrical, temperature, mechanical and chemical. Unless otherwise specified, the following "transformer" includes shaver transformers, power transformers built shaver and shaver supply unit Means. This section applies in a vertical, single-phase air-cooled (self-cooled or air-cooled), with independent or supporting the use of dry-type transformers. Windings can be Encapsulated or non-encapsulated type. This section applies to the internal operating frequency not exceeding 500Hz transformers and power supply (linear). This section also applies to the internal operating frequency exceeding 500Hz power and should be used in conjunction with GB 19212.17. When the two standards When a conflict, give priority to the most stringent standards. Rated supply voltage not exceeding AC 250V, rated supply frequency not exceeding 500Hz. 20VA rated output of not less than and not more than 50VA. Load output voltage does not exceed AC 275V, and the rated output voltage does not exceed AC 250V. This section does not apply to scheduled to be connected to the input and output terminals or output receptacle transformer circuit and external components. When installation procedures or between the bathroom and electrical specification requirements for the installation site similar circuit is double or reinforced insulation, you can use this It comprises a portion of a transformer. Note 2. This section includes a transformer can be fitted in or surface mounted on the lighting and mirrors, or mount containing one or more of its output socket He inside the machine. Note 3. The following should be noted. --- Transformer predetermined use on a vehicle, ship or aircraft, additional requirements may be necessary (according to other applicable standards, national regulations, etc.); --- Avoid the housing and the housing components such as protective measures by the outside influence of mold, insects, termites, solar radiation, and icing should also be considered; --- Transformer transport, storage and different conditions of work should also be considered; --- Intended to be used for special circumstances transformers can be used in line with national standards and other applicable rules of the additional requirements. Note 4. With the future development of transformer technology, may need to increase the upper limit frequency, but before then, you can use this section as a guide.

2 Normative references

In addition to the following references, GB 19212.1-2008 this chapter apply. The increase in the following chapter references. GB 19212.1-2008 "power transformers, power supplies, reactors and similar products - Part 1. General requirements and tests No. 1 amendments (IEC 61558-1Ed2.0AMENDEMENT1, IDT) IEC 60068-2-62. 1.1991 Environmental testing for electric and electronic products Part 2. Test methods Test Ef. pendulum impact 2) (Environmentaltesting-Part 2. Testmethods-TestEf. Impact, pendulumhammer) 2) The standard has been IEC 60068-2-75.1997 instead, but because of the need in this section, so the IEC 60068-2-62. 1.1991 is still reference. IEC 60670 (alparts) for household and similar fixed electrical installations and electrical accessory mounting box housing [Boxesandenclo- suresforelectricalaccessoriesforhouseholdandsimilarfixedelectricalinstalations]

3 Terms and Definitions

In addition to the following terms and definitions outside, GB 19212.1-2008 this chapter apply. The chapter increase following terms and definitions. 3.1.101 Shaver transformers shavertransformer As fixing means and having a limited output, designed for electric shavers, electric toothbrushes in the bathroom and a rated output of no more than use 50VA other similar devices powered isolation transformer. It can only give a razor or similar means power. 3.1.102 Shaver supply means shaversupplyunit Equipped with electrical accessories shaver transformers or shaver is equipped with a transformer power supply unit with a once only allowed to use One or more plug outlet.

4 General requirements

This chapter applies the GB 19212.1-2008. General Description 5 tests This chapter applies the GB 19212.1-2008.

6 RATINGS

GB 19212.1-2008 this chapter and replaced by the following. 6.101 should not exceed the rated output voltage AC 250V. 6.102 rated output of not less than 20VA, and should not exceed 50VA. 6.103 Rated power supply frequency and internal operating frequency should not exceed 500Hz. Rated supply voltage should not exceed 6.104 AC 250V. Flag by visual inspection to verify compliance with the requirements of 6.101 ~ 6.104. Category 7 In addition to the following terms outside, GB 19212.1-2008 this chapter apply. Article 7.2 is replaced by the following. Press the short circuit protection or abnormal conditions of protection Category. --- Inherent short-circuit proof transformers; --- Non-inherent short-circuit proof transformer.

8 Marking and other information

In addition to the following terms outside, GB 19212.1-2008 this chapter apply. Article 8.1 of h) the first sentence is replaced by the following. 8.11 gives a graphical representation of the transformer label. The article n), the following modifications. For the transformer, if the degree of protection higher than IP00, protection class IP code shall be marked. For razor-powered device, if the degree of protection higher than IP21, protection class IP code shall be marked. 8.7 Addition of the following. For razor-powered device is equipped with single-pole switch, the switch should be connected to the phase line pole. 8.11 Addition of the following. Symbol or graphic symbol or name identification code Description Shaver power supply units and transformers IEC 60417-5225 (2009-05) 8.13 Addition of the following. For razor-powered devices, the rated output voltage and a 8.11 mark symbol shall be marked on the front of the housing, so that the device Press When installed properly be clearly visible. For providing different output voltages to predetermined shaver supply means, the selected output voltage Setpoint should be clearly identified. For the transformer, the transformer only when a separate power supply shall be marked with the symbol 8.11.

9 Protection against electric shock

This chapter applies the GB 19212.1-2008. 10 change the input voltage setpoint This chapter applies the GB 19212.1-2008. 11 load output voltage and output current This chapter applies the GB 19212.1-2008. 12 no-load output voltage In addition to the following terms outside, GB 19212.1-2008 this chapter apply. The chapter increased the following provisions. 12.101 AC load output voltage should not exceed 275V. For independent transformer, the output voltage is not a predetermined limit also applies to the output windings connected to each other but were connected in series. 12.102 no-load output voltage difference between the output voltage and the load should not be too large. Meets the requirements of 12.101 and 12.102, and should be adopted at ambient temperature for the transformer connected to the rated frequency of the rated supply voltage, Load output voltage measurements to check. This chapter measured no-load output voltage difference and in Chapter 11 test measured load output voltage, when expressed as a percentage of the latter When, should not exceed 20%. NOTE. This ratio is defined as follows. U -U load load U × 100% load 13 short-circuit voltage This chapter applies the GB 19212.1-2008. Fever 14 This chapter applies the GB 19212.1-2008. 15 short-circuit and overload protection This chapter applies the GB 19212.1-2008. 16 Mechanical strength In addition to the following terms outside, GB 19212.1-2008 this chapter apply. Article 16.1 is replaced by the following. For razor-powered device, by the test of 16.101 eligibility. Addition of the following. 16.101 shaver power supply device according to the following provisions, with the pendulum impact test performed. 16.101.1 according to IEC 60068-2-62. 1.1991 regulations on the impact test samples. For razor-powered devices Surface-mounted installation, samples should be IEC 60068-2-62. 1.1991 specified in 4.2 will be installed. For razor-powered device concealed installation, the samples should be IEC 60068-2-62. 1.1991 specified in FIG. 3 for installation. Flush-mounted screws screw type device application to the recess in the mounting block in the lug; concealed jaw stationary equipment shall jaw Direct snapped into the slot in the block installed. Samples should be properly installed so that the point of impact is on the vertical plane through the axis of the pendulum. Before applying the blows, with equal to 25.1 GB 19212.1-2008 in two-thirds of the torque specified in Table 11 the base, and the lid Similar parts fixing screws and tighten. The striking element should be dropped from the height of the table 101 regulations. Table 101 Drop height Drop height cm Approximate energy Related sites 10 ± 0.1 0.2 Cover and recessed depth razor flush mounted power supply means at least Those portions of the concave portion of the fourth largest size 15 ± 0.1 0.3 shell 25 ± 0.1 0.5 Other section 16.101.2 samples should withstand 10 times the impact, the 10 blows should be evenly distributed in the sample. 5 blows following provisions shall be applied. --- For scheduled to be concealed razor-mounted power supply unit, at the center of the impact is applied once, and then moving the sample level, Pillow block recess located at each end of the range of each applied for 1 shocks applied to the other two times approximate midpoint between the point of impact Impact; --- For not intended to be concealed razor-mounted power supply unit, once applied to strike at the center, then the sample do about a vertical axis Can turn (but rotated by an angle of not more than 60 °) after each side of the sample is applied to each hit once, above the point of impact The approximate midpoint between two blows is then applied. The sample is then about an axis perpendicular to the plywood rotated by 90 ° in the same manner as the rest of the impact is applied. If you have cable entry, the sample shall be mounted so that two rows of the point of impact as far as possible and the distance between the cable entry as possible equal. After 16.101.3 test, the sample should not damage within the meaning of this section appears. In particular, live parts shall not become accessible. Note 1. The surface layer is damaged, it does not make the creepage distances or clearances reduced to less than a small dent in Chapter 26, a predetermined value, and does not protect against electric shock or moisture Adversely affect small pieces negligible. Note 2. In case no additional amplification, normal or corrected vision invisible cracks and fiber-reinforced molding......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 19212.6-2013_English be delivered?

Answer: Upon your order, we will start to translate GB 19212.6-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 19212.6-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB 19212.6-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 19212.6-2013?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19212.6-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.