Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB 15322.3-2019 English PDF

US$399.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 15322.3-2019: Combustible gas detectors -- Part 3: Portable combustible gas detectors for industrial and commercial use
Status: Valid

GB 15322.3: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 15322.3-2019399 Add to Cart 4 days Combustible gas detectors -- Part 3: Portable combustible gas detectors for industrial and commercial use Valid
GB 15322.3-2003759 Add to Cart 4 days Combustible gas detectors -- Part 3: portable detectors for 0~100%LEL combustible gas Obsolete

Similar standards

GB 15322.1   GB 14287.1   GB 14287.3   GB/T 45839   GB 20517   GB 15322.2   

Basic data

Standard ID: GB 15322.3-2019 (GB15322.3-2019)
Description (Translated English): Combustible gas detectors -- Part 3: Portable combustible gas detectors for industrial and commercial use
Sector / Industry: National Standard
Classification of Chinese Standard: C81
Classification of International Standard: 13.220.20
Word Count Estimation: 20,224
Date of Issue: 2019-10-14
Date of Implementation: 2020-11-01
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB 15322.3-2019: Combustible gas detectors -- Part 3: Portable combustible gas detectors for industrial and commercial use


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Combustible gas detectors--Part 3. Portable combustible gas detectors for industrial and commercial use ICS 13.220.20 C81 National Standards of People's Republic of China Replacing GB 15322.3-2003, GB 15322.6-2003 Combustible gas detector Part 3. Portable for industrial and commercial use Combustible gas detector Combustiblegasdetectors-Part 3. Portablecombustiblegas Published on.2019-10-14 2020-11-01 implementation State market supervision and administration China National Standardization Administration issued

Content

Foreword I 1 Scope 1 2 Normative references 1 3 Category 1 4 Requirements 1 4.1 General 1 4.2 Appearance requirements 2 4.3 Performance 2 4.4 Detection of the response of gases other than methane, propane and carbon monoxide 6 5 Test 7 5.1 Test Outline 7 5.2 Basic performance test 9 5.3 Alarm action value test 9 5.4 Range indication deviation test 9 5.5 Response time test 10 5.6 Azimuth test 10 5.7 Alarm repeatability test 10 5.8 High-speed airflow test 10 5.9 Battery Capacity Test 11 5.10 Electrostatic discharge immunity test 11 5.11 Radio Frequency Electromagnetic Field Radiation Immunity Test 11 5.12 High temperature (running) test 11 5.13 Low temperature (running) test 12 5.14 Constant damp heat (running) test 12 5.15 Vibration (sinusoidal) (running) test 12 5.16 Vibration (sinusoidal) (durability) test 12 5.17 Drop Test 13 5.18 Anti-poisoning performance test 13 5.19 Anti-high concentration gas impact performance test 13 5.20 Low concentration operation test 13 6 Inspection rules 14 6.1 Factory inspection 14 6.2 Type inspection 14 7 logo 14 7.1 General 14 7.2 Product Mark 14 7.3 Quality inspection mark 15

Foreword

All technical content in this section is mandatory. GB 15322 "combustible gas detector" is divided into the following parts. --- Part 1. Point-type combustible gas detectors for industrial and commercial use; --- Part 2. Household flammable gas detectors; --- Part 3. Portable combustible gas detectors for industrial and commercial use; --- Part 4. Linear and flammable gas detectors for industrial and commercial use. This part is the third part of GB 15322. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces GB 15322.3-2003 "Combustible gas detectors Part 3. Portable with a measuring range of 0~100% LEL Combustible gas detectors and GB 15322.6-2003 "Combustible gas detectors - Part 6. Portable flammable gas detector". Compared with GB 15322.3-2003 and GB 15322.6-2003, the main technical changes in this section are as follows. --- Combine the contents of GB 15322.3-2003 and GB 15322.6-2003 into one part; --- According to the measurement range, the detectors are divided into three types. detectors with measuring range between 3%LEL and 100% LEL, measuring range Detectors below 3% LEL and detectors measuring over 100% LEL. Divide the detector according to the way of working There are two types. continuous working detectors and single measuring detectors (see Chapter 3, GB 15322.3-2003 and Chapter 4 of GB 15322.6-2003); --- Increased the requirements for the detector concentration display function (see 4.3.1.5); ---Modified the test conditions of the high temperature (running) test and the low temperature (running) test, and alarmed the detector under various test conditions Action value requirements (see Chapter 4, GB 15322.3-2003 and Chapter 5 of GB 15322.6-2003); --- Increased anti-poisoning performance test (see 4.3.12); --- Increased low concentration operation test (see 4.3.14). This part is proposed and managed by the Emergency Management Department of the People's Republic of China. This section drafted by. Shenyang Fire Research Institute of Emergency Management Department, Chengdu Anchuang Electronics Co., Ltd., Hanwei Technology Group Co., Ltd., Fuyang Huaxin Electronic Instrument Co., Ltd., Jinan Benan Technology Development Co., Ltd., Yingjisen Safety Fire System (Shanghai) Co., Ltd. Company, Beijing Weitai Safety Equipment Co., Ltd., Xi'an Bokang Electronics Co., Ltd., Shanghai Dajiang Electronic Instrument Co., Ltd. The main drafters of this section. Guo Chunlei, Fei Chunxiang, Guan Mingyang, Guo Rui, Xie Feng, Ding Hongjun, Kang Weidong, Zhang Yingxi, Zhao Yu, Wang Qiang, Jiang Miaofei, Deng Lihong, Zhao Yingran, Jiang Bo, Meng Yu, Zhu Gang, Wang Yuxiang, Li Keting, Jia Dongmei. The previous versions of the standards replaced by this section are. ---GB 15322-1994; ---GB 15322.3-2003; ---GB 15322.6-2003. Combustible gas detector Part 3. Portable for industrial and commercial use Combustible gas detector

1 Scope

This part of GB 15322 specifies the classification, requirements, tests, inspection rules and regulations for portable flammable gas detectors for industrial and commercial use. Sign. This section applies to industrial and commercial applications for the detection of hydrocarbons, ethers, esters, alcohols, carbon monoxide, hydrogen and other combustibles. Portable flammable gas detector (hereinafter referred to as "detector") for gas and vapor. Special properties used in industrial and commercial locations The detectors may also be implemented in addition to the special requirements specified by the relevant standards.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB 3836.1-2010 Explosive atmosphere - Part 1. General requirements for equipment GB/T 9969 General guidelines for the use of industrial products GB 12978 Fire Electronic Product Inspection Rules GB 15322.1-2019 flammable gas detectors - Part 1. flammable gas detectors for industrial and commercial use GB/T 16838 Fire electronic products environmental test methods and severity GB/T 17626.2-2018 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test

3 classification

3.1 According to the measurement range is divided into. a) detectors measuring between 3% LEL and 100% LEL; b) detectors measuring below 3% LEL (including detectors for detecting carbon monoxide); c) Detectors with a measurement range of 100% LEL or more. Note. The lower explosive limit (LEL) is the lowest explosive concentration of flammable gas or vapor in the air. 3.2 Divided into working methods. a) continuous working type detectors; b) Single measurement type detector.

4 requirements

4.1 General The detector shall meet the relevant requirements of Chapter 4 and be tested in accordance with the provisions of Chapter 5 to confirm the detector's requirements for Chapter 4.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 15322.3-2019_English be delivered?

Answer: Upon your order, we will start to translate GB 15322.3-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 15322.3-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB 15322.3-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 15322.3-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 15322.3-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.