GB 14536.4-2008: [GB/T 14536.4-2008] Automatic electrical controls for household and similar use -- Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
Status: Valid

GB 14536.4: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 14536.4-2008389 Add to Cart 3 days [GB/T 14536.4-2008] Automatic electrical controls for household and similar use -- Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps Valid
GB 14536.4-1996399 Add to Cart 3 days Automatic electrical controls for household and similar use. Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps Obsolete

Similar standards

GB 14536.16   GB 14536.11   GB 14536.15   GB/T 14536.7   GB/T 14536.12   GB/T 14536.1   

Basic data

Standard ID: GB 14536.4-2008 (GB14536.4-2008)
Description (Translated English): [GB/T 14536.4-2008] Automatic electrical controls for household and similar use -- Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
Sector / Industry: National Standard
Classification of Chinese Standard: K32
Classification of International Standard: 29.120.60
Word Count Estimation: 15,149
Date of Issue: 2008-12-30
Date of Implementation: 2010-02-01
Older Standard (superseded by this standard): GB 14536.4-1996
Quoted Standard: GB 14536.1
Regulation (derived from): Announcement of Newly Approved National Standards No. 26 of 2008 (total 139)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard is suitable for thermal protectors for ballasts for tubular fluorescent assessment is made ??. This standard applies to the use of PTC and NTC thermistor thermal protection, and its additional requirements, see Appendix J. Ballast and thermal protection fitted together test requirements, see GB 19510. 1. 1. 1. 1 this standard applies to the inherent safety of the ballast protection for safety -related operations and equipment value, the operating time and operating procedures applicable to prevent overheating tubular fluorescent ballasts thermal protector tests. This standard applies to GB 19510. 9 within the ballast thermal protector. Covered in this standard also applies to thermal protector GB 19510. 10 within the scope of other discharge lamps. Note: this standard, the term"protection"refers to a"fluorescent lamp can be self-resetting thermal protector. "1. 1. 2 this standard does not apply to protect the ballast and other devices. 1. 1. 3 this standard does not apply to artificial means to break the circuit. 1. 2 Replacement: this standard is intended for use in frequency 50Hz or 60Hz, AC 690V power supply voltage does not exceed the ballast protector. 1. 3 Replacement: this standard does not provide protection in the device with the installation method for automatic operation of the protective response. If the response value for the protection of users and the surrounding environment secure meaningful, then the corresponding equipment standards set forth in the response or the response by the manufacturer to determine the value in this standard apply.

GB 14536.4-2008: [GB/T 14536.4-2008] Automatic electrical controls for household and similar use -- Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Automatic electrical controls for household and similar use.Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps ICS 29.130.20 K32 National Standards of People's Republic of China GB 14536.4-2008/IEC 60730-2-3.2006 Replacing GB 14536.4-1996 Household and similar electrical automatic controller Tubular fluorescent lamp ballasts Particular requirements for thermal protectors (IEC 60730-2-3.2006, IDT) Posted 2008-12-30 2010-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ IEC Introduction Ⅲ 1 Scope and normative references 1 2 Definitions 1 3 2 General requirements 4 General notes 2 Rating 2 5 6 Category 2 7 Profile 2 8 Protection against electric shock 3 9 3 ground protection measures 10 Terminals and terminations 4 11 structural requirements 4 12 moisture and dust 4 13 Electric strength and insulation resistance 4 14 fever 4 15 Manufacturing deviation and drift 4 16 5 Environmental Stress 17 overload, endurance and limited short-circuit 5 18 mechanical strength 6 19 Threaded parts and connections 6 20 creepage distances, clearances and distances through solid insulation through 6 21 heat, fire and resistance to tracking 6 22 6 corrosion resistance 23 Electromagnetic compatibility (EMC) emission requirements --- 6 24 assembly 6 25 Normal operation 6 26 Electromagnetic compatibility (EMC) requirements --- immunity 6 27 non-normal operation 7 28 Guidelines for the use of electronic disconnection 7 Appendix 8 Annex C (normative) mercury switch test cotton 8 Appendix E (normative) Measurement of leakage current circuit 8 GB 14536.4-2008/IEC 60730-2-3.2006

Foreword

All technical content in this section is mandatory. GB 14536 "Household and similar electrical automatic controller" is divided into two parts. --- Part 1. General requirements; --- Part 2. Particular requirements. Special requirements and consists of the following components. --- GB 14536.3 - Particular requirements for thermal motor protectors (IEC 60730-2-2, IDT); --- Particular requirements GB 14536.4 tubular fluorescent lamp ballasts for thermal protectors (IEC 60730-2-3, IDT); --- GB 14536.5 sealed and semi-hermetic motor - compressor motor thermal protection Particular requirements (IEC 60730-2-4, IDT); --- Particular requirements GB 14536.6 automatic electrical burner control systems (IEC 60730-2-5, IDT); --- GB 14536.7 pressure sensitive electrical controls - Particular requirements (idt IEC 60730-2-6); --- GB 14536.8 Particular requirements for timers and time switches (idt IEC 60730-2-7); --- GB 14536.9 Particular requirements for electrically operated water valves (including mechanical requirements) (IEC 60730-2-8, IDT); --- GB 14536.10 - Particular requirements for temperature sensing controls (IEC 60730-2-9, IDT); --- GB 14536.11 Particular requirements for motor starting relays (IEC 60730-2-10, IDT) used; --- GB 14536.12 Particular requirements for energy regulators (idt IEC 60730-2-11); --- GB 14536.13 Particular requirements for electrically operated door locks (IEC 60730-2-12, IDT); --- GB 14536.15 Particular requirements for humidity sensing controls (IEC 60730-2-13, IDT); --- GB 14536.16 Particular requirements for electric actuators (idt IEC 60730-2-14); --- GB 14536.17 special requirements of the float or electrode-sensitive automatic electrical water level sensing controller used in the boiler appliance (IEC 60730-2-15, IDT); --- GB 14536.18 - Particular requirements for household and similar use of the float type level controllers (IEC 60730-2-16, IDT); --- GB 14536.19 Particular requirements for electrically operated gas valves, including mechanical requirements (IEC 60730-2-17, IDT); --- GB 14536.20 Particular requirements for water and air flow sensing controls, including mechanical requirements (IEC 60730-2-18, IDT); --- GB 14536.21 Particular requirements for electrically operated oil valves, including mechanical requirements (IEC 60730-2-19, IDT); This section identical with IEC 60730-2-3.2006 "Household and similar electrical automatic controller thermal protectors for ballasts for tubular fluorescent lamps Particular requirements. " Part of this structure with IEC 60730-2-3.2006 same. In this section, there is a corresponding national standard, incorporated by reference to national standards; No national standards, IEC standards are incorporated by reference outlined. For ease of use, this section made the following editorial changes. a) instead of as a decimal by decimal comma ",". ","; b) increase the national standard foreword; c) with the "GB 14536.1" instead of "Part 1." This part of GB 14536.1-2008 "Household and similar electrical controls - Part 1. General requirements" in conjunction. This Part replaces GB 14536.4-1996 "household and similar use automatic controller tubular fluorescent lamp ballasts special thermal protection Specific requirements. " Compared with GB 14536.4-1996 part of the main changes are as follows. GB 14536.4-2008/IEC 60730-2-3.2006 a) description of the scope of Chapter 1, made some changes and added a reference standard; b) the information provided in Chapter 7 added some content; c) Chapter 16 environmental stress content has been adjusted; d) the name of several sections according to changes GB 14536.1 made the appropriate changes; e) delete the applicability described in Appendix D. This section of the Appendices C and E are normative appendix. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee household automatic control (SAC/TC212) centralized. This section is drafted. Guangzhou CVC Testing Institute, Guangzhou Electric Apparatus Research Institute, Ningbo Economic and Technological Development Zone Haixin Electric Technology Co., Ltd. The main drafters of this section. Du, Huang Kaiyun, Zheng Guoping like. This part of the standard replaces the previous editions are. --- GB 14536.4-1996. GB 14536.4-2008/IEC 60730-2-3.2006 IEC Foreword 1) IEC (International Electrotechnical Commission) is a worldwide standardization group composed of national electrotechnical committees (IEC National Committees) Organizations. The object of IEC is to promote international cooperation on issues related to the standardization of the electrical and electronic fields. For this purpose IEC addition to other activities, but also publishes International Standards, technical specifications, technical reports, public specification (PAS, Publicly AvailableSpecifications) and guidelines (henceforth referred to IEC publication). Their preparation is entrusted to technical Commission to complete. As a member of IEC National Committees, as long as the interest of the standard to be developed, may participate Its formulation. Liaising with the IEC 's international, official or unofficial organizations are also involved in the development of standards. IEC and the World Organization for Standardization (ISO ) in accordance with the conditions specified in the agreement, close cooperation. 2) IEC IEC National Committees on technical issues formal decisions or agreements of particular concern on this issue with all the skills to participate Technique developed by the Commission and, where possible expressed consensus on the issues involved in the international arena. 3) IEC Publications have the form of recommendations for international use, and in this sense recognized by the National Committees. Do its utmost to ensure Paul IEC standard technology content is correct at the same time, IEC for end users or use any translation errors live responsibility. 4) In order to promote international unification, IEC National Committees should clearly maximize the IEC international standards into the country Standard or region. In case of any difference between the standard and the corresponding national or regional standard IEC , should be national standards or Regional standards clearly stated. 5) IEC not developed any sign of approval procedures. When a device is declared if it complies with one of its standards of IEC , IEC this Assumes no responsibility. 6) All users should be sure you are using the latest version. 7) IEC or its leaders, employees, servants or agents, including independent experts and IEC technical committees, national committee Members will, for the use of any person or the trust of the IEC standards or other IEC publication caused casualties, property damage Loss or other damage to the natural environment (whether such losses are direct or indirect) does not bear any responsibility for the phase Should produce costs and expenses (including legal fees) is not liable. 8) Note that the standard references mentioned in this publication. Publication reference standard for the correct application of this standard is indispensable. 9) Note that some of the contents of this publication may involve patents, IEC these patent rights will not be responsible. IEC 60730-2-3 the IEC /T C72. home automation controller Technical Committee. This second edition will repeal and replaces the first edition (1990) and its Amendment 1 (1995) and Amendment 2 (2001). The second version of the standard package Including a technical amendment. This updated version of the standard IEC 60730-1 third edition (1999) and its Amendment 1 (2003). Standard text based on the following documents. FDIS Report on voting 72/709/FDIS 72/722/RVD All the information related to this standard by voting, vote on the report, see the table below. The publication is in accordance with ISO /IEC Guide is the second part of the drafting. This section should be used in conjunction with IEC 60730-1. To IEC 60730-1 3rd edition (1999) and its Amendment 1 (2003) as the base Basis, you should consider IEC 60730-1 subsequent versions or revisions. This part supplements or modifies the corresponding provisions in the IEC 60730-1, IEC standards formed. tubular fluorescent lamp ballasts special thermal protection Specific requirements. This section, where marked "increase", "Edit", "instead of" place, IEC 60730-1 corresponding requirements, test specifications or comments should be done GB 14536.4-2008/IEC 60730-2-3.2006 Amended accordingly. This part of the chapter or indicate the appropriate provisions apply without modification place. In the development of a complete international standard-setting process, we must take into account the different requirements of the actual situation of the world is formed, and should distinguish Differences in each country's electrical systems and wiring rules. Differences in different countries in order to "Note. In some countries," given form, these differences appear in the following clauses. --- Table 7.2 101; --- 12.2; --- 17.4; --- Appendix C; --- Appendix D. This publication uses the following fonts. --- Test Requirements Body. roman; --- Test specifications. italic; --- Note. The small Roman font. IEC 60730-1 based on the increase in chapters, notes, terms of number from 101 onwards, additional annexes letters AA, BB, etc. represent. In the IEC website, can be found in General requirements "for household and similar use automatic controller" as the basis of all the IEC 60730 series Standard directory. The Committee decided that the contents of this publication in the IEC 's website http. // webstore. iec. On ch marked, and specific publications related Before the next revision date remains unchanged, but to this date, the publication will be. ● reconfirmed; ● Cancel; ● The revised version was replaced; or ● Amendment. GB 14536.4-2008/IEC 60730-2-3.2006 Household and similar electrical automatic controller Tubular fluorescent lamp ballasts Particular requirements for thermal protectors

1 Scope and normative references

GB 14536.1 of the chapter is applicable except as follows. 1.1 Replacement. This section applies to a tubular fluorescent lamp ballasts thermal protectors made its assessment. This section applies to the use of PTC and NTC thermistor thermal protection, its additional requirements in Appendix J. Ballast and thermal protection fitted together test requirements see GB 19510.1. 1.1.1 This section applies to the inherent safety ballast protector for safety equipment and related operating values, operating time and operating procedures Order, adapted to prevent the thermal protection to the tubular fluorescent lamp ballast overheating test. This section applies to thermal protectors for ballasts within the range of GB 19510.9. This section covered by a thermal protector is also applicable to other discharge lamps within the range of GB 19510.10. Note. in this section, the term "protection" refers to the "self-resetting thermal protector of fluorescent lamps." 1.1.2 This section does not apply to other means to protect the ballast. 1.1.3 This section does not apply to artificial means breaking the circuit. 1.2 Replacement. This section is intended for use in the frequency of 50Hz or 60Hz, 690V AC power supply voltage does not exceed the protection of the ballast. 1.3 Replacement. This section response and protection in the equipment installation methods related to the protection of non-automatic operation of the provisions. If the response to Paul Protect the user and the surrounding environment safe sense, the response values in the appropriate equipment standard specified by the manufacturer or determined response Applicable in this standard. 1.5 Normative References The following documents contain provisions which, through reference in this Part of GB 14536, constitute provisions of this part. Cited documents dated, its All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage each agreement under this section Are Prescriptions can use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. increase. Part 1 GB 19510.1 lamp control apparatus. General and safety requirements (GB 19510.1-2004, IEC 61347-1. 2003, IDT) Part 9 control devices GB 19510.9 Lamp. Particular requirements for ballasts for fluorescent lamps (GB 19510.9-2004, IEC 61347-2-8.2000, IDT) Particular requirements for discharge lamps (excluding fluorescent lamps) Ballast. Part 10 GB 19510.10 lamp control device (GB 19510.10-2004, IEC 61347-2-9.2003, IDT)

2 Definitions

GB 14536.1 of the chapter is applicable except as follows. increase. 2.2.16.101 Mounted in tubular fluorescent lamp ballasts or with integral ballast, and the ballast is designed to prevent excessive under any conditions of use GB 14536.4-2008/IEC 60730-2-3.2006 The self-resetting thermal automatic controller. NOTE. The controller carries ballast and ballast current temperature and current sensitive.

3 General requirements

This is applicable in GB 14536.1. General Description 4 Test GB 14536.1 of the chapter is applicable except as follows. 4.2 Sample Requirements instead. 4.2.1 with a single test specimen 17.1.2, 17.4 test conducted three separate samples, test the remaining projects By another separate sample.

5 RATINGS

This is applicable in GB 14536.1. Category 6 GB 14536.1 of the chapter is applicable except as follows. 6.3 By Application increase. 6.3.101 --- Ballast thermal protection. 6.4 Classification by automatically operating characteristics 6.4.1 --- Not applicable. increase. 6.4.101 micro-cutting operation to provide protection is further classified as follows. --- Automatic reset type (2.C type). 6.6 and 6.7 do not apply. 6.10 ~ 6.12 NA. 6.14 Not applicable. 6.16 Not applicable.

7 Information

GB 14536.1 of the chapter is applicable except as follows. Table 7.2 instead. Information chapter, strip method 1 manufacturer name or trademark b) 7.2.6 C The only sign model 2 a), b) 2.11.1 and 2.13.1 C 3 rated voltage or rated voltage range/V 2.1.2 and 4.3.2 C 4 If the controller is not dual AC-DC current, or AC and DC ratings Different, then to mark the nature of supply 4.3.2 and 6.1 D GB 14536.4-2008/IEC 60730-2-3.2006 Table 7.2 (Continued) Information chapter, strip method 6 uses the controller 4.3.5 and 6.3 D Structure 6a Controller 6.15 D 20 depicts the internal conductor terminals for connecting wire dedicated 10.2.1 D 31 Installing the controller method e) 11.6 D Maximum and/or minimum rate of change of the starting amount of 37, or sensitive controller minimum and/or Maximum cycle rate d) 4, 15 and 17 X Overshoot value 38 correct action necessary to control the starting amount of sensitive or used in the test 17 X Operation 15 D 48 value increase. 101 Limited short-circuit capacity 101) 17.4 X Rated current 102 102) and 17 D 2.1.1 a) The only model of such a sign is a sign that when fully referenced this flag, the controller will be able to offer manufacturers in the electrical and mechanical properties, dimensional And the new controller with the original controller function exactly the same. Other marks may be such as ambient temperature or voltage rating and a series of models composed together to provide a unique model flag. b) vacancies. d) α2 is the maximum rate of rise (only for type 2 actions) β2 is the maximum rate of decrease (only for type 2 actions) Values α2 and β2 merely to test only provisions, therefore, can also be defined as the maximum cycle rate. In order to meet the standards requirements, changes in temperature Rate should be K/h to represent. e) If the controller is installed independently, and, when the installation or use of that time and the controller must take special measures, these measures should be in control Detailed description is given submission. For example, to install a separate controller installed, you may need to take special measures. In order to ensure after loading can meet the requirements of this section, these controllers The instructions shall include the following information. --- Install the controller required size of the space, the space of the supporting and fixing the size and position of the controller components used; Minimum clearance around the various components and assembly --- between the controller; --- Minimum size vent their correct arrangement; Methods --- controller and power supply connected and if there are discrete components, discrete method of interconnection between components. If the controller power wires can come into contact with a terminal board wiring or fixed separator member, and these components under normal temperature conditions Table 14.1 will exceed a predetermined value, the controller should also provide instructions to use with a corresponding T rating wires to connect (see Table 14.1 Note a). 101) 17.4 Test for Canada and the United States. 102) Ballast thermal protection rated current of the rated current by a ballast should be selected.

8 Protection against electric shock

This is applicable in GB 14536.1.

9 ground protection measures

This is applicable in GB 14536.1. GB 14536.4-2008/IEC 60730-2-3.2006 10 Terminals and terminations GB 14536.1 of the chapter is applicab......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 14536.4-2008_English be delivered?

Answer: Upon your order, we will start to translate GB 14536.4-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 14536.4-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB 14536.4-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 14536.4-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 14536.4-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.