Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB 1260-2008 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 1260-2008: Working chemical -- Zinc oxide
Status: Valid

GB 1260: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 1260-2008169 Add to Cart 3 days Working chemical -- Zinc oxide Valid
GB 1260-1990279 Add to Cart 3 days Working chemical--Zinc oxide Obsolete

Similar standards

HG/T 3489   GB/T 1282   HG/T 3484   GB 1258   GB 6853   GB 1256   

Basic data

Standard ID: GB 1260-2008 (GB1260-2008)
Description (Translated English): Working chemical -- Zinc oxide
Sector / Industry: National Standard
Classification of Chinese Standard: G61
Classification of International Standard: 71.040.30
Word Count Estimation: 7,797
Date of Issue: 2008-06-18
Date of Implementation: 2009-06-01
Older Standard (superseded by this standard): GB 1260-1990
Regulation (derived from): Announcement of Newly Approved National Standards No. 10 of 2008 (total 123)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard specifies the Working chemical properties of zinc oxide, specifications, testing, inspection and marking and packaging rules. This standard applies to Working chemical titration analysis of zinc oxide test.

GB 1260-2008: Working chemical -- Zinc oxide

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Working chemical.Zinc oxide ICS 71.040.30 G61 National Standards of People's Republic of China Replacing GB 1260-1990 Working Standard reagent zinc oxide Posted 2008-06-18 2009-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

The standard Chapter 4, 5.3.1 and 5.3.2 are mandatory, other provisions are recommended. This standard replaces GB 1260-1990 "work reference reagent (capacity) zinc oxide," compared with GB 1260-1990, major changes as follows. --- Standard name was changed to "work reference reagent zinc oxide"; --- Modify the Content Measurement (1990 version 4.1, this version 5.3); --- Abolition of the "standard solution formulated Appendix A (Supplement)" (1990 edition Appendix A). The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee Chemistry Chemicals Branch (SAC/TC63/SC3) centralized. This standard is drafted by. Beijing Institute of chemical reagents. The main drafters of this standard. Han Baoying, strong Jing Lin. This standard replaces the standards previously issued as follows. --- GB 1260-1977, GB 1260-1990. Working Standard reagent zinc oxide Molecular formula. ZnO Molecular Weight. 81.389 (according to 2005 international relative atomic mass).

1 Scope

This standard specifies the job reference reagent zinc oxide properties, specifications, testing, packaging and inspection rules and signs. This standard applies to titration analysis work reference reagent zinc oxide test.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. Preparation of GB/T 601 chemical reagent standard titration solution GB/T 602 Determination of impurities in chemical reagents prepared standard solution (GB/T 602-2002, ISO 6353-1. 1982, NEQ) with GB/T 603 chemical reagent test method Preparations of articles (GB/T 603-2002, ISO 6353-1 with. 1982, NEQ) GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD) GB/T 9723-2007 Chemicals flame atomic absorption spectrometry General GB/T 9728 General method for determination of chemical reagents sulfate (GB/T 9728-2007, ISO 6353-1. 1982, NEQ) GB/T 9729 General method for determination of chloride Chemicals (GB/T 9729-2007, ISO 6353-1. 1982, NEQ) GB 10738 Job reference reagent titration Determination General Weighing GB 15346 chemical reagent packaging and marking HG/T 3484 standard chemical reagents glass emulsion and clarity standards HG/T 3921 Chemicals sampling and acceptance rules

3 Characters

This reagent is white or light yellow crystalline powder, insoluble in water, soluble in acid, ammonia and alkali metal hydroxide solution, the absorption in air Carbon dioxide and water.

4 Specification

Zinc oxide as shown in Table 1. Table 1 Name reference work Content (ZnO), /% 99.95 ~ 100.05 Clarity test, number ≤2 Loss on ignition, /% ≤0.2 The free base of qualified Chloride (Cl), /% ≤0.001 Sulfur compounds (of SO4), /% ≤0.005 Table 1 (continued) Name reference work Nitrate (NO3), /% ≤0.003 Magnesium (Mg), /% ≤0.002 Calcium (Ca), /% ≤0.005 Iron (Fe), /% ≤0.0005 Lead (Pb), /% ≤0.003 Potassium permanganate reducing substance (in O gauge), /% ≤0.0016

5 Test

5.1 Warning Reagents used in this test method are toxic or corrosive, some of the testing process can lead to dangerous situations, the operator should take Appropriate safety and health practices. 5.2 General Provisions Unless specified otherwise in this chapter, the use of standard titration solution, standard solution, preparations and products, according to GB/T 601, GB/T 602, Regulations preparation, test water should be consistent with GB/T 6682 specifications in three water samples according to precise weighing 0.01g, the use of GB/T 603's Solution "%" are represented by the mass fraction. 5.3 Content Measured according to GB 10738 requirements. 5.3.1 disodium EDTA standard titration solution of zinc oxide material standard titration Weigh 0.1g to 800 ℃ burning zinc oxide material to a constant standard of accuracy to 0.00001g, placed in a reaction flask with a little water Wetting, was added dropwise a solution of hydrochloric acid (20%) to the zinc oxide dissolved, add 75mL water, the solution was adjusted to pH 8 with aqueous ammonia solution (10%), plus 10mL ammonia - ammonium chloride buffer solution A (pH10) and 3 drops of chrome black T indicator solution (5g/L), with disodium EDTA standard titration solution [Ba (EDTA) = 0.05mol/L] titration solution from purple to pure blue. Weighing disodium EDTA standard titration solution, precise To 0.0001g. Determination 5.3.2 Content Determination with 5.3.1, measuring the sample after loss on ignition instead of the standard substance. Zinc oxide content and its value is "%" means, according to equation (1). (1) Where. B --- Standard Substance content of zinc oxide (mass fraction), the value to "%" means; 5.4 Clarity test 6g weighed sample was dissolved in 94mL 6mL water and sulfuric acid, which must not be greater than clarity turbidity standard HG/T 3484 stipulated 2. 5.5 loss on ignition Weigh 1.5g sample, accurate to 0.0001g, has been placed at 800 ℃ to constant burning platinum crucible in a high temperature furnace gradually warming To 800 ℃ to constant and burning. Samples retained after constant for determination. Loss on ignition 1, the value in the "%" means, according to equation (2). 100 (2) Where. 5.6 free base Weigh 2g sample, add 20mL water, boiled, filtered, cooled. The filtrate was added 2 drops of phenolphthalein indicator solution (10g/L), the solution may not form powder red. 5.7 Chloride Weigh 1g sample, add 5mL water was added dropwise a solution of nitric acid (25%) to dissolve the sample, diluted to 20mL, according to GB/T 9729 regulations Determination. The turbidity of the solution was not greater than the standard turbidity solution. Standard preparation turbid solution is to take the ratio of 0.01mg containing chloride (Cl) standard solution was diluted to 20mL, and at the same time with the same volume of test solution Sample processing. 5.8 sulfur compounds Weigh 1g sample, add water 15mL, 0.2mL of anhydrous sodium carbonate solution (50g/L), and 1mL "30% hydrogen peroxide", slowly boil To bubble Yat do, a solution of hydrochloric acid solution (20%) was dissolved, evaporated to near dryness on a water bath, dissolved in water and diluted to 20mL, according to GB/T 9728 regulations Fixed determination. The turbidity of the solution was not greater than the standard turbidity solution. Standard preparation turbid solution is to take the ratio of 0.05mg containing sulfate (SO4) standard solution was diluted to 20mL, at the same time with the same volume of test solution The same treatment. 5.9 Nitrate Weigh 0.5g sample was dissolved in 10mL water, 1mL sodium chloride solution (100g/L) and indigo carmine solution 1mL [Ba (C16H8N2Na2O8S2) = 0.001mol/L], with shaking in the 10s ~ 15s add 10mL sulfuric acid, placed 10min, shaking By slowly added 10mL of water and shake. The solution can not be a pale blue standard colorimetric solution. Preparation of the standard developing solution containing 0.015mg is to take the ratio of nitrate (NO3) standard solution, the same treatment simultaneously with the sample. 5.10 Magnesium Determined according to the provisions of GB/T 9723-2007 of. 5.10.1 Instrument Conditions Source. magnesium hollow cathode lamp; Wavelength. 285.2nm; Flame. acetylene - air. 5.10.2 Determination 5g samples were weighed, wetted with a small amount of water was added dropwise a solution of hydrochloric acid (20%) to dissolve the sample, diluted to 100mL. Take 20mL, a total of four Parts. According to the provisions of GB/T 9723-2007 7.2.2 measurement results calculated according to the provisions of 7.2.3. 5.11 Calcium Determined according to the provisions of GB/T 9723-2007 of. 5.11.1 Instrument Conditions Source. calcium hollow cathode lamp; Wavelength. 422.7nm; Flame. acetylene - air. 5.11.2 Determination 10g samples were weighed, wetted with a small amount of water was added dropwise a solution of hydrochloric acid (20%) to dissolve the sample, diluted to 100mL. Take 20mL, a total of four Parts. According to the provisions of GB/T 9723-2007 7.2.2 measurement results calculated according to the provisions of 7.2.3.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 1260-2008_English be delivered?

Answer: Upon your order, we will start to translate GB 1260-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 1260-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB 1260-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 1260-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 1260-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.