Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 11030-2008 English PDF

US$229.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 11030-2008: Characteristics of rod ceramic insulators for a.c. contact system of electrified railways
Status: Valid

GB/T 11030: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 11030-2008229 Add to Cart 3 days Characteristics of rod ceramic insulators for a.c. contact system of electrified railways Valid
GB 11030-2000439 Add to Cart 4 days Loss of bulk petroleum liquid products Obsolete
GB 11030-1989RFQ ASK 3 days Anti-pollution type rod porielain insulators for the contact networks of railway a. c traction system Obsolete

Similar standards

DL/T 1000.1   DB12/ 356   DL/T 1000.3   GB/T 44179   GB/T 24622   GB/T 21421.1   

Basic data

Standard ID: GB/T 11030-2008 (GB/T11030-2008)
Description (Translated English): Characteristics of rod ceramic insulators for a.c. contact system of electrified railways
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K48
Classification of International Standard: 29.080.10
Word Count Estimation: 10,155
Date of Issue: 2008-06-30
Date of Implementation: 2009-04-01
Older Standard (superseded by this standard): GB 11030-2000
Quoted Standard: GB/T 1001.1-2003
Regulation (derived from): Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard applies to the nominal voltage of 25kV, frequency single-phase AC electrified railway catenary Rod porcelain insulator (hereinafter referred to as insulators). This standard applies to light- polluted area, heavy pollution areas and high altitudes catenary wrist and arm support insulators. This standard specifies the electrical insulator properties, mechanical properties and dimensional characteristics (see Table 1). This standard also specifies the insulator models and methods of marking. Note 1: GB/T 1001. 1-2003 general definition given in the test method. Note 2: GB/T 1001. 1-2003 The term " electric traction lines " with this standard, the term " electric railway " has the same meaning.

GB/T 11030-2008: Characteristics of rod ceramic insulators for a.c. contact system of electrified railways


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Characteristics of rod ceramic insulators for accontact system of electrified railways ICS 29.080.10 K48 National Standards of People's Republic of China Replacing GB 11030-2000 Exchange of electrified railway catenary with Rod porcelain insulators Characteristics Posted 2008-06-30 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard replaces GB 11030-2000 "ac traction lines with porcelain insulators Rod" in size and features section. This standard compared with GB 11030-2000 in the size and nature of the content main changes are as follows. --- Increasing the mechanical failing load 12kN and 16kN level two varieties, delete the tunnel with hanging and positioning of two formula Species; --- Creepage distances former 1000mm, 1200mm and 1500mm three kinds of change 1200mm, 1400mm and 1600mm Three kinds; --- Remove the original standard in Appendix A "method of measuring the quality and appearance of the glaze layer semiconductor resistance" content added "Insulators cantilever Jack location of the pin "content; --- Remove the original standard Appendix B "transitional insulator main dimensions and characteristics of the" content, increase the "old model, said insulator party Law "content. This standard should be GB/T 1001.1-2003 "nominal high voltage overhead line insulators above 1000V - Part 1. System AC Ceramic or glass insulator element definitions, test methods and acceptance criteria "used in conjunction. Appendix A of this standard and Appendix B is an informative annex. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee Insulators (SAC/TC80) centralized. This standard was drafted. Xi'an Institute of Electric Porcelain, Third Railway Survey and Design Institute, Suzhou Cichang like. The main drafters of this standard. Dingjing Ling, Guo Wei Gong, Lu Chau. This standard replaces the standards previously issued as follows. --- GB 11030-1989, GB 11030-2000. Exchange of electrified railway catenary with Rod porcelain insulators Characteristics

1 Scope

This standard applies to nominal voltage of 25kV, AC single-phase power frequency electric railway catenary Rod porcelain insulators (hereinafter referred to as absolute Edge sub). This standard applies to light-polluted area, heavy polluted area and high altitudes catenary cantilever supporting insulators. This standard specifies the characteristics of electrical insulators, mechanical properties and dimensional characteristics (see Table 1). This standard also specifies the insulator model and methods of marking. Note 1. A general definition, test method GB/T 1001.1-2003 in. Note 2. GB/T 1001.1-2003, the term "electric traction lines" with this standard, the term "railway electrification" has the same meaning.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 1001.1-2003 nominal voltage above 1000V Insulators for overhead lines - Part 1. Ceramic or glass AC system Glass insulator element definitions, test methods and acceptance criteria (IEC 60383-1.1993, MOD)

3 models and signs

How to order. Exchange of electrified railway catenary Rod porcelain insulators Minimum bending failing load (digital)/kN D represents a single insulated, S indicates double insulation Lightning impulse withstand voltage (digital)/kV ๎—…๎—…๎—… The minimum nominal creepage distance (Digital)/mm For example, Q12S-310/1600, he said. Q --- AC electrified railway catenary Rod porcelain insulators; 12 --- minimum bending failure load 12kN; S --- double insulated; 310 --- lightning impulse withstand voltage 310kV; 1600 --- The minimum nominal creepage distance of 1600mm. 4 electrical, mechanical and dimensional characteristics This standard specifies the following characteristics. --- Minimum mechanical failing load;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 11030-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 11030-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 11030-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 11030-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 11030-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11030-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.