GB 1094.5-2008 English PDF

US$759.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 1094.5-2008: [GB/T 1094.5-2008] Power transformers -- Part 5: Ability to withstand short circuit
Status: Valid

GB 1094.5: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 1094.5-2008759 Add to Cart 5 days [GB/T 1094.5-2008] Power transformers -- Part 5: Ability to withstand short circuit Valid
GB 1094.5-2003719 Add to Cart 5 days Power transformers -- Part 5: Ability to withstand short circuit Obsolete
GB 1094.5-1985279 Add to Cart 3 days Power transformers--Part 5: Ability to withstand short circuit Obsolete

Similar standards

GB 1094.1   GB/T 1094.7   GB/T 1094.11   GB/T 1094.14   

Basic data

Standard ID: GB 1094.5-2008 (GB1094.5-2008)
Description (Translated English): [GB/T 1094.5-2008] Power transformers -- Part 5: Ability to withstand short circuit
Sector / Industry: National Standard
Classification of Chinese Standard: K41
Classification of International Standard: 29.180
Word Count Estimation: 29,252
Date of Issue: 2008-09-19
Date of Implementation: 2009-06-01
Older Standard (superseded by this standard): GB 1094.5-2003
Quoted Standard: GB 1094.1-1996; GB 1094.3-2003; GB 1094.11-2007; GB/T 13499-2002
Adopted Standard: IEC 60076-5-2006, MOD
Regulation (derived from): Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard applies to power transformer short circuit caused by an external overcurrent damage under the action should be required. This standard describes the characterization of power transformer overcurrent withstand this heat capacity calculation procedures and ability to withstand the dynamic stability of the corresponding special experimental and theoretical assessment methods (see Appendix A). This standard applies to GB 1094. 1 within the specified range of the transformer.

GB 1094.5-2008: [GB/T 1094.5-2008] Power transformers -- Part 5: Ability to withstand short circuit


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Power transformers.Part 5. Ability to withstand short circuit ICS 29.180 K41 National Standards of People's Republic of China Replacing GB 1094.5-2003 Power Transformer Part 5. ability to withstand short circuit (IEC 60076-5.2006, MOD) Posted 2008-09-19 2009-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 Ability to withstand short circuit of claim 3 1 3.1 General 1 3.2 overcurrent condition 1 Ability to withstand short circuit verification 4 3 4.1 ability to withstand short circuit Heat 4 4.2 ability to withstand short circuit dynamic stability 5 Appendix A (informative) ability to withstand short-circuit dynamic stability theory to assess 11 A. 1 Scope 11 A. 2 Overview 11 A. 11 3 Design Review Guidelines Appendix B (Informative Appendix) IEC 60076-5.2006 system short-circuit capacity of the apparent 21 Annex C (informative) similar to the transformer 22 is determined

Foreword

Part of Chapters 3 and 4 are mandatory, the rest are recommended. GB 1094 "Power Transformers" currently contains the following sections. --- Part 1. General; --- Part 2. temperature rise; --- Part 3. Insulation levels, dielectric tests and external insulation air gap; --- Part 4. Power transformers and reactors lightning impulse and switching impulse testing guidelines; --- Part 5. ability to withstand short circuit; --- Part 7. oil-immersed power transformer loading guidelines; --- Part 10. Determination of sound levels; --- Part 10.1. Determination of sound levels --- Application guide; --- Part 11. Dry-type transformers. This section GB 1094 Part 5. The partial modification using IEC 60076-5.2006 "Power transformers Part 5. Ability to withstand short circuit" (in English). This section according to IEC 60076-5.2006 modifying the principles adopted by redrafting. Taking into account China's national conditions, in using IEC 60076-5.2006 when this part has made several modifications. About the technical differences have been incorporated into positive This paper identifies and vertical single line in which they are involved with the provisions margin. This part of IEC 60076-5.2006 Main technical Differences are as follows. --- Cited international standards of our standards, rather than a direct reference to international standards; --- Considering the circumstances of the transformer short-circuit impedance values in Table 1. 3.2.2.3 Added "Note 3. The different rated capacity and Specific short-circuit impedance voltage level value, see the appropriate standard. "; --- Taking into account the specific circumstances of the grid system, the equipment 3.2.2.4 Table 2 the highest voltage and short circuit according to China's apparent capacity The actual situation of the grid voltage levels are listed, and the IEC 60076-5.2006, the corresponding provisions listed in Appendix B to facilitate Control. For ease of use, this section of IEC 60076-5.2006 made the following editorial changes. --- Remove the IEC 60076-5.2006 Foreword; --- Appendix A Note 1 The contents moved footnote 7); --- With a decimal point "." Instead of a comma as the decimal point "." This Part replaces GB 1094.5-2003 "Power transformers Part 5. Ability to withstand short circuit." This section compared with GB 1094.5-2003 main changes are as follows. --- Added "normative references"; --- Added "System Short nominal system voltage of 750kV apparent capacity"; --- Increase the "ability to withstand short-circuit dynamic stability theory assessment" informative appendix. This section of the Appendix A, Appendix B and Appendix C are informative appendices. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee transformers (SAC/TC44) centralized. This section is drafted. Shenyang Transformer Research Institute, TBEA Shenyang Transformer Group Co., Ltd., Xi'an Electric transformer limited liability Any company, Baoding Tianwei Electric Co., Ltd., Shanghai Electric Power Company, TBEA Hengyang Transformer Co., Ltd., Beijing Huatai change Pressure Co., Ltd, and Power Electric Group Co., Ltd., Guangzhou Prosperous Electric Co., Ltd., Shandong Dachi Electric Co., Ltd. The main drafters of this section. Guo Yan, Zhang Zhong country, Tao Dan, Zhong Juntao Wang Long, Zhang joy, Jiang Yimin, Chen Dongfeng, Wang hl Xuzi Hong, Fan Jianping, Xu Changhua. This part of the standard replaces the previous editions are. --- GB 1094.5-1971, GB 1094.5-1979, GB 1094.5-1985, GB 1094.5-2003. Power Transformer Part 5. ability to withstand short circuit

1 Scope

GB 1094 This section provides power transformers in the overcurrent effect caused by an external short circuit should be no damage to the requirements. This section It describes the characterization of power transformers withstand such heat resistance over current calculation program and bear the corresponding test special ability and dynamic stability Theoretical Assessment Method (see Appendix A). This section applies to GB 1094.1 Suo transformer within the scope of the provisions.

2 Normative references

The following documents contain provisions which, through reference in this Part of GB 1094 constitute provisions of this section. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Whether the parties can study the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB 1094.1-1996 Power transformers - Part 1. General (eqv IEC 60076-1.1993) GB 1094.3-2003 Power transformers Part 3. Insulation levels, dielectric tests and external insulation air gap (IEC 60076-3. 2000, MOD) GB 1094.11-2007 Power transformers Part 11. Dry-type transformers (IEC 60076-11.2004, MOD) GB/T 13499-2002 Application guide for power transformers (idt IEC 60076-8.1997) Claim 3 Ability to withstand short circuit 3.1 General Transformer and its components and accessories shall be designed and manufactured to withstand external short circuit under the conditions specified in this section 3.2 and the thermal efficiency of dynamic stability It should be no damage. External short circuit includes a three-phase short circuit, phase short circuit, two phase to ground and ground fault. These fault currents induced in the windings in Part Points referred to as "over-current." 3.2 overcurrent conditions 3.2.1 General Conditions 3.2.1.1 require special consideration of conditions Following cases overcurrent size, duration or frequency of occurrence of an impact, the need for special consideration and should be in the transformer technical specification Give clearly defined. --- Regulating transformer impedance small, we need to consider the impedance of the current limiting device is connected; --- Generator transformers are vulnerable because the generator is connected with the loss of synchronization system produced higher overcurrent; --- Direct rotary motor (such as a motor or a synchronous phase modulation device) connected to the transformer under system fault conditions, the state of power generation was run The rotary transformer supplying current to the motor; --- Special transformers and transformer installed in a high failure rate of the system (see 3.2.6); --- Failure, higher than the rated operating voltage fault occurs on a non-terminal. 3.2.1.2 Current limit on boosting transformer When combined impedance transformer and booster systems lead to short-circuit current value is so great that the design withstand this excess current transformer is difficult or without When the economic, manufacturing and users should consult together to determine the maximum allowable over current value. In this case, the user should take measures to limit the overcurrent to producing The determined and the flag over the maximum current value on the nameplate. 3.2.2 having two separate windings 3.2.2.1 This section provides a three-phase or three-phase transformer rated capacity of the group is divided into three categories. Ⅰ class. 25kVA ~ 2500kVA; Ⅱ class. 2501kVA ~ 100000kVA; Ⅲ class. 100000kVA above. 3.2.2.2 Unless otherwise specified, symmetrical short-circuit current (rms value, see 4.1.2) shall be measured transformer short-circuit impedance coupled system Short-circuit impedance calculation. For class Ⅰ transformer, if the system short-circuit impedance is equal to or less than 5% of the transformer short-circuit impedance, the short-circuit current calculation system Short-circuit impedance should be negligible. Peak short-circuit current 4.2.3 should be calculated. 3.2.2.3 Table 1 shows the minimum value of the transformer short-circuit impedance at rated current (primary tap) under, if you need a lower short-circuit impedance value When the transformer to withstand short circuit capacity by producing and user consultation. Table 1 has a minimum of two independent short-circuit impedance of the transformer windings Rated capacity/kVA Minimum short-circuit impedance /% 25 to 630 631 to 1250 1251 to 2500 2501 ~ 6300 6301 to 25,000 25001 to 40000 40001 ~ 63000 63001 to 100000 Than 100,000 4.0 5.0 6.0 7.0 8.0 10.0 11.0 12.5 > 12.5 Note 1. The rated capacity is greater than the short-circuit impedance value is generally determined by the manufacturer 100000kVA and users negotiation. Note 2. In the case of the single-phase transformers three-phase group, the value of the rated capacity for three-phase group. Note 3. The different rated capacity and voltage levels of specific short-circuit impedance values, see the appropriate standard. 3.2.2.4 In order to obtain a symmetrical short-circuit current design and testing required by the user to provide the Department of the installed location of the transformer at the time of inquiry Short-circuit the system apparent capacity. If no apparent short-circuit the system capacity, in accordance with Table 2 selection. Table 2 System Short apparent capacity Nominal System Voltage/kV highest voltage for equipment Um/kV apparent short circuit capacity/MVA 6,10,20 7.2,12,24 40.5 72.5 18,000 60,000 Note 1. If not specified, the system is considered zero sequence impedance positive sequence impedance ratio is 1 to 3. Note 2. If the user requires otherwise, the system short-circuit apparent capacity can also be specified in Appendix B of the selection, but it should be specified in the contract. 3.2.2.5 transformer having two separate windings, usually only consider a three-phase short circuit, which can be considered virtually fully satisfy other possible (Except for special circumstances contemplated in Note 3.2.5), including the type of fault. NOTE. When the windings Zigzag Connection, a single earth fault currents may be larger than the three-phase short circuit current. However, the two involved in the stem, higher electrical Current value is limited to half of the windings. Further, the current in the other star-connected windings are less than the current three-phase short circuit. As for the three-phase Single-phase short circuit or a short circuit on the dynamic stability of the windings produces more damage, and structural design of the windings related. Manufacturing and users should consider what kind of short Road type agreement. 3.2.3 multi-winding transformers and autotransformers Winding (including stable and auxiliary windings) overcurrent shall be determined according to the impedance transformer and systems. The operation should be considered It can produce different types of system failures, such as. the transformer and grounding systems and related ground fault and phase fault (see GB/T 13499-2002). Characteristics of each system (at least in the short-circuit depending on the capacity and zero sequence impedance positive sequence impedance ratio in the range) should Presented by the user at the time of inquiry. Triangle three-phase transformer coupling stabilizing winding should be able to withstand the operation may arise, and related systems and ground conditions relating Different types of system failures arising from overcurrent. In the case of the single-phase transformers three-phase group unless the user will confirm the special protection measures to prevent phase short circuit, the stable Winding should be able to withstand short-circuit its terminals. NOTE. The auxiliary winding designed to withstand short-circuiting its terminals may not be economical. At this time, it should take appropriate measures (such as the use of series reactors, or In some cases the use of fuses) to limit the over-current value. In addition, it should pay attention to prevent the line section between the transformer and its Short-protection device Circuit fault. 3.2.4 booster transformer Booster transformer impedance value may be small, so the winding overcurrent mainly by the characteristics of the system at the installation location of the transformer to determine set. These features should be user inquiry and ordering made. If the booster transformer is connected directly to a transformer for the voltage amplitude and/or phase shift adjustment, this should be able to withstand up transformer Both devices synthesizing the impedance produced by an overcurrent. 3.2.5 directly connected with other electrical transformer When the transformer is directly connected with other electrical appliances, the electrical impedance will limit the short circuit current. Press Association between the manufacturer and users Yee, you can transformers, transformer directly connected to the system and with the respective electrical impedance counted in the total. If the connection between the generator and the transformer is good, even in this context the possibility of two-phase or phase to ground fault can be ignored Not time, the above also applies to the generator transformer. NOTE. If the connection status between the generator and the transformer as described above, then for neutral grounding of the star - delta-connected generator transformers, with Star connection winding is connected to system ground fault occurs, or in the case of the generator is not synchronized with the system, it is the most serious short-circuit may occur Happening. 3.2.6 special transformers and transformer installed in the high failure rate of the system For special occasions (such as electric transformers and transformer to the traction power supply systems) or operating conditions (such as the failure of the connected system More often), transformer withstand frequent over-current capability, and users should manufacture specialized consultation. About the system of abnormal operating conditions The case member, the user should be provided in advance to the manufacturing side. 3.2.7 tap changer When the transformer is equipped with tap-tap-winding should be able to withstand the same short-circuit overcurrent. But it does not require on-load tap-changer Having the ability to switch the short-circuit current. 3.2.8 neutral point terminal Star-connected or zigzag coupling winding neutral terminal shall be the maximum possible flow through this terminal over current designs.

4 Ability to withstand short circuit verification

Requirements of this chapter applies to both prescribed GB 1094.1 oil-immersed power transformers, also apply to dry under the GB 1094.11 Power transformers. 4.1 heat resistance to withstand short circuit 4.1.1 Overview Transformer short-circuit withstand heat capacity should be verified by means of calculation. Calculation according to the provisions of 4.1.2 - 4.1.5. 4.1.2 Symmetrical short-circuit current I For two independent three-phase transformer winding, symmetrical short-circuit current rms value I shall be calculated as follows. I = U Sang 3 × (Zt + Zs) (1) Where. I --- symmetrical short-circuit current rms value, in kA (kA); Zs --- system short-circuit impedance, ohms per phase (Ω) (equivalent star connection), calculated as follows. Zs = U (2) Where. Us --- nominal system voltage, in kilovolts (kV); S --- System Short apparent capacity, units of MVA (MVA). U and Zt according to the following provisions. a) For the main tap. U --- considered rated voltage Ur winding unit is kilovolt (kV); Zt --- converted to the windings considered short-circuit impedance 1), each phase ohms (Ω) (equivalent star connection), calculated as follows. Zt = z t × U 100Sr (3) 1) where the symbol Zt t and z are used instead of GB 1094.1-1996 Z and z, which is consistent with the purpose of this section 4.2.3, in order to avoid confusion. 2) tap voltage is defined in GB 1094.1-1996 5.2. Where. Z t --- at the reference temperature, rated current and rated frequency measured by the main tap short-circuit impedance, expressed in%; Sr --- transformer rated capacity, in units of MVA (MVA). b) In addition to the other outside the main tap tap. U --- considered in the corresponding tapped winding voltage (unless otherwise specified) 2) units of kilovolts (kV); Zt --- converted to the corresponding tap winding consider short-circuit impedance per phase ohms (Ω) represents. For multi-winding transformers, autotransformers, booster transformers and transformer directly connected to other appliances, which were calculated overcurrent Press 3.2.3,3.2.4 3.2.5 or conduct. All transformers, except the 3.2.2.2 circumstances, should consider the system short-circuit impedance. NOTE. Zigzag Connection of winding, single-phase ground fault circuit current may be significantly greater than the three-phase short circuit fault current. Therefore, in the calculation of Zigzag Connection Winding temperature rise should consider increasing the current value. 4.1.3 Symmetrical short-circuit current duration Unless otherwise specified, the duration of the heat is used to calculate the short-circuit withstand capability of the current I is 2s. Note. For auto-transformer and short circuit current exceeds 25 times the rated current of the transformer, after consultation with users of manufacturing, short-circuit current duration may be small To 2s. 4.1.4 The maximum permissible value of each winding mean temperature After each winding, respectively, for applying a predetermined duration of the symmetrical short-circuit current I by 4.1.2 and 4.1.3, which at any tap position The average temperature θ1 should not exceed the maximum specified in Table 3. Winding temperature equation (4) and Equation (5) used in the θ0 should be expressed as maximum allowable ambient temperature and at rated conditions resistor The winding temperature measurement and. If the measured winding temperature rise is not applicable, winding starting temperature θ0 should be the maximum permissible ambient temperature Winding insulation system allows temperature sum. Table 3 each winding after short circuit at an average temperature of the maximum allowable value Type transformers Insulation system temperature / (Thermal insulation levels in brackets) The maximum temperature / Aluminum winding copper windings Oil-immersed 105 (A) 250 200 Dry 105 (A) 120 (E) 130 (B) 155 (F) 180 (H) Note 1. When the wi......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 1094.5-2008_English be delivered?

Answer: Upon your order, we will start to translate GB 1094.5-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 1094.5-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB 1094.5-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 1094.5-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 1094.5-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.