Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 6913-2023English185 Add to Cart 0-9 seconds. Auto-delivery Analysis of water used in boiler and cooling system - Determination of phosphate Valid
GB/T 6913-2008English399 Add to Cart 3 days Analysis of water used in boiler and cooling system -- Determination of phosphorus Obsolete
GB/T 6913.1-1986English199 Add to Cart 2 days Methods for analysis of water for boiler and for cooling--The determination of phosphates--Orthophosphates Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 6913-2023
      

Similar standards

GB/T 6913   GB/T 6907   GB/T 6903   

GB/T 6913-2023: Analysis of water used in boiler and cooling system - Determination of phosphate

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT6913-2023
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.040.40 CCS G 76 Replacing GB/T 6913-2008 Analysis of water used in boiler and cooling system - Determination of phosphate (ISO 6878:2004, Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method, NEQ) ISSUED ON: MARCH 17, 2023 IMPLEMENTED ON: OCTOBER 01, 2023 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China.

Table of Contents

Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 5 4 Ammonium molybdate spectrophotometric method ... 5 5 Continuous flow-ammonium molybdate spectrophotometric method ... 11 6 Test report ... 14 Appendix A (Normative) Things to note during the test ... 15 Appendix B (Informative) Interference judgment and elimination of coexisting ions 16 Appendix C (Normative) Continuous flow analyzer system performance check ... 18 Analysis of water used in boiler and cooling system - Determination of phosphate Warming: The strong acid and strong base which are used in this document are corrosive. Avoid inhalation or contact with the skin during use. If it splashes on the body, use plenty of water to rinse it immediately. If serious, seek medical advice immediately.

1 Scope

This document describes methods for the determination of orthophosphate, total inorganic phosphate, and total phosphate content in water used in boiler and cooling system: ammonium molybdate spectrophotometric method and continuous flow- ammonium molybdate spectrophotometric method. This document applies to the determination of orthophosphate, total inorganic phosphate, and total phosphate content in water used in boiler and cooling system. The measurement range of the ammonium molybdate spectrophotometric method is 0.05 mg/L ~ 50 mg/L (based on PO43-); the measurement range of the continuous flow- ammonium molybdate spectrophotometric method is 0.1 mg/L ~ 50 mg/L (based on PO43-).

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document. GB/T 6682-2008, Water for analytical laboratory use - Specification and test methods

3 Terms and definitions

No terms and definitions need to be defined in this document.

4 Ammonium molybdate spectrophotometric method

4.1 Determination of orthophosphate content 4.1.1 Method summary In the presence of acidic media and antimonic salts, orthophosphate reacts with ammonium molybdate solution to produce yellow phosphomolybdenum heteropoly acid. Use ascorbic acid to reduce it to phosphomolybdenum blue, and measure it by the spectrophotometric method at a wavelength of 710 nm. The reaction formula is: 4.1.2 Reagents or materials Unless otherwise specified, only use analytical reagents or above. 4.1.2.1 Water: GB/T 6682-2008, grade 3. 4.1.2.2 Ascorbic acid solution: 100 g/L. Store it in brown bottles at 4 °C, valid for 14 days. 4.1.2.3 Ammonium molybdate solution: 26 g/L. Weigh 13 g of ammonium molybdate and 0.35 g of potassium antimony tartrate (KSbOC4H4O6·1/2H2O); dissolve in 200 mL of water; add 230 mL of sulfuric acid solution (1+1); mix well; cool and use water to dilute to 500 mL; shake well. Store it in brown bottles, valid for 2 months. 4.1.2.4 Phosphate standard stock solution (based on PO43-): 500 mg/L. Weigh 0.716 5 g of potassium dihydrogen phosphate that has been dried to a constant weight at 100 °C ~ 105 °C, accurate to 0.2 mg; dissolve in about 500 mL of water; transfer to a 1 000 mL volumetric flask; use water to dilute to the mark; shake well. 4.1.2.5 Phosphate standard solution (based on PO43-): 20 mg/L. Pipette 20.00 mL of phosphate standard stock solution into a 500 mL volumetric flask; use water to dilute to the mark; shake well. Formulate this solution when needed. 4.1.3 Instruments and apparatuses Spectrophotometer: Equipped with an absorption cell with a thickness of 1 cm. 4.1.4 Test procedure 4.1.4.1 Preparation of sample Filter the water sample collected on site through medium-speed filter paper and collect into clean and dry glass bottles for subsequent analysis. Operate things to note during the test according to Appendix A. See Appendix B for the interference judgment and elimination of coexisting ions in the sample. 4.3.2.3 Potassium persulfate solution: 40 g/L. Store in brown bottles, valid for 14 days. 4.3.2.4 Other reagents: Same as 4.1.2. 4.3.3 Instruments and apparatuses Spectrophotometer: Equipped with an absorption cell with a thickness of 1 cm. 4.3.4 Test procedure Transfer an appropriate volume of sample (4.1.4.1) to a 100 mL Erlenmeyer flask by referring to Table 1; add water to approximately 40 mL. Add 1.0 mL of sulfuric acid solution and 5.0 mL of potassium persulfate solution; place it on an electric furnace to maintain a slight boil for about 30 minutes for digestion. When boiling, add water regularly to keep the solution volume at 25 mL ~ 30 mL. After cooling, use sodium hydroxide solution to adjust the pH to 3 ~ 10 and transfer to a 50 mL volumetric flask. Add 2.0 mL of ammonium molybdate solution and 1.0 mL of ascorbic acid solution; use water to dilute to the mark; shake well; leave at room temperature for 10 minutes. Use a spectrophotometer to measure the absorbance at a wavelength of 710 nm with a 1 cm absorption cell and a blank as a reference. Note: Other digestion methods, such as microwave digestion, can also be used. 4.3.5 Result calculation 4.3.5.1 The total phosphate (based on PO43-) content ρ3 is expressed in terms of mass concentration, in milligrams per liter (mg/L), and is calculated according to Formula (3): Where: m – the mass of PO43- found from the calibration curve (4.1.4.2) or calculated from the regression equation, in micrograms (μg); V – the volume of the sample transferred, in milliliters (mL). Express the calculation result to two digits after the decimal point. 4.3.5.2 The organophosphate (based on PO43-) content ρ4 is expressed in terms of mass concentration, in milligrams per liter (mg/L), and is calculated according to Formula (4): Adjust the instrument according to the instrument instruction manual to achieve optimal usage conditions. After starting up, first replace the reagent with water to check the tightness of the entire analysis flow path and the smoothness of the liquid flow. After the baseline stabilizes (about 20 minutes), the system begins to take the reagent package. After the baseline stabilizes again, proceed to the measurement of total phosphate according to 5.4.3 ~ 5.4.4. When measuring orthophosphate, use water instead of potassium persulfate solution; turn off the hydrolysis heating and UV digestion functions of the total phosphate analysis module for measurement. When measuring total inorganic phosphate, use water instead of potassium persulfate solution, and turn off the UV digestion function of the total phosphate analysis module for measurement. 5.4.2 Preparation of calibration solutions Respectively pipette 0.00 mL (blank), 0.50 mL, 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL, 5.00 mL, 6.00 mL and 7.00 mL of phosphate standard solution into nine 50 mL volumetric flasks, corresponding to the PO43- mass concentrations of 0.00 mg/L, 0.50 mg/L, 1.00 mg/L, 2.00 mg/L, 3.00 mg/L, 4.00 mg/L, 5.00 mg/L, 6.00 mg/L and 7.00 mg/L. 5.4.3 Drawing of calibration curve Add an appropriate amount of phosphate standard series solution (larger than the instrument’s liquid absorption capacity) to the sample cup; use the injector to sample and measure in sequence according to the program. Draw a calibration curve with the measured signal value as the ordinate and the corresponding mass concentration of PO43- (mg/L) as the abscissa. 5.4.4 Determination Measure the sample (4.1.4.1) using the blank as a reference under the same conditions as for drawing the calibration curve. If the phosphate content in the sample exceeds the range of the calibration curve, it shall be measured after dilution. Note: When using a continuous flow analyzer for measurement, the type and concentration of the solution in the required reagent package, the flow and flow rate of the reagent, and the range of the calibration curve will vary depending on the model of the instrument. The user shall choose the best test conditions according to the instrument model. 5.5 Calculation of results The phosphate (based on PO43-) content ρ is expressed in terms of mass concentration, in milligrams per liter (mg/L), and is calculated according to Formula (5):

Appendix A

(Normative) Things to note during the test A.1 Filtration of water sample The water sample shall be filtered within 4 hours after collection, and the filtration time shall not exceed 10 minutes. If the temperature of the water sample is lower than room temperature, the sample shall be brought to room temperature before filtering. The first 10 mL of filtrate shall be discarded during filtration. A.2 Cleaning of glassware Before use, all glassware shall be soaked in hydrochloric acid solution (1+4) or nitric acid solution (1+4) for more than 12 hours, and then washed thoroughly with water. Regularly use sodium hydroxide solution (80 g/L) to wash the absorption cell or detector, and then rinse thoroughly with water to remove colored complex deposits attached to the glassware. A.3 Calibration of absorption cell Before the test, the absorption cell shall be calibrated to eliminate differences between different absorption cells. A.4 Decomposition of organophosphorus substance In the presence of a large amount of organic matter, the decomposition effect of potassium persulfate is poor, and nitric acid and perchloric acid shall be used to decompose organic matter. The operation is as follows: accurately pipette a certain volume of sample; add 2 mL of nitric acid and 1 mL of perchloric acid; heat on an adjustable electric furnace until brown vapor no longer comes out and white crystals appear. After cooling, add water and heat slightly until a clear and transparent solution is obtained. Use sodium hydroxide solution (80 g/L) to adjust the pH to 7 ~ 9. A.5 Processing and storage of water sample To ensure that the water sample does not change, it is best to measure it immediately after taking the sample. If the measurement cannot be carried out immediately, adjust the pH to less than 2 with sulfuric acid and store it in a glass bottle at 4 °C.

Appendix C

(Normative) Continuous flow analyzer system performance check C.1 Reagents or materials C.1.1 Phosphate standard solution: 50 mg/L, same as 5.2.9. C.1.2 Sodium pyrophosphate standard stock solution: 500 mg/L (based on PO43-). Weigh 1.173 8 g of sodium pyrophosphate decahydrate; dissolve it in an appropriate amount of water; transfer it to a 1 000 mL volumetric flask; use water to dilute it to the mark; shake well. Store at 4 °C, valid for 3 months. C.1.3 Sodium pyrophosphate standard solution: 2.50 mg/L (based on PO43-). Pipette 10.00 mL of sodium pyrophosphate standard stock solution into a 100 mL volumetric flask; use water to dilute to the mark; shake well. Pipette 5.00 mL of the above solution into a 100 mL volumetric flask; use water to dilute to the mark; shake well. Formulate this solution when needed. C.1.4 Pyridoxal-5-phosphate standard stock solution: 500 mg/L (based on PO43-). Weigh 0.279 1 g of pyridoxal 5-phosphate; dissolve it in an appropriate amount of water; transfer it to a 200 mL volumetric flask; use water to dilute to the mark; shake well; store in a brown glass bottle. Store at 4 °C, valid for 3 months. C.1.5 Pyridoxal-5-phosphate standard solution: 2.50 mg/L (based on PO43-). Pipette 10.00 mL of pyridoxal-5-phosphate standard stock solution into a 100 mL volumetric flask; use water to dilute to the mark; shake well. Pipette 5.00 mL of the above solution into a 100 mL volumetric flask; use water to dilute to the mark; shake well. Formulate this solution when needed. C.2 Performance check Use sodium pyrophosphate standard solution to verify the hydrolysis efficiency of the method, and use pyridoxal-5-phosphate standard solution to verify the digestion efficiency of the method. Generally, the test is performed once every 2 weeks. Parallelly measure sodium pyrophosphate standard solution (when measuring orthophosphate or total inorganic phosphate) or pyridoxal-5-phosphate standard solution (when measuring total phosphate) and phosphate standard solution; calculate the hydrolysis or digestion efficiency R according to Formula (C.1), where R shall be greater than 90%. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB/T 6913-2023 be delivered?

Answer: The full copy PDF of English version of GB/T 6913-2023 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 6913-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 6913-2023_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB/T 6913-2023 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB/T 6913-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6913-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB/T 6913-2023?

A step-by-step guide to download PDF of GB/T 6913-2023_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 6913-2023".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9