DL/T 1000.3-2015: Application guide of insulators for overhand lines with a nominal voltage over 1000V - Part 3: Composite insulator for a.c. system
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
DL/T 1000.3-2015English370 Add to Cart 0-9 seconds. Auto-delivery Application guide of insulators for overhand lines with a nominal voltage over 1000V - Part 3: Composite insulator for a.c. system Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: DL/T 1000.3-2015
      

Similar standards

DB35/T 1753   DB12/ 356   DL/T 1000.6   

DL/T 1000.3-2015: Application guide of insulators for overhand lines with a nominal voltage over 1000V - Part 3: Composite insulator for a.c. system


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/DLT1000.3-2015
DL ELECTRICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.020 K 48 Filing No.: 50770-2015 Replacing DL/T 864-2004 Application guide of insulators for overhead lines with a nominal voltage over 1000V - Part 3: Composite insulator for a.c. system ISSUED ON: JULY 01, 2015 IMPLEMENTED ON: DECEMBER 01, 2015 Issued by: National Energy Administration

Table of Contents

Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 6 4 General technical requirements ... 8 5 Selection principles ... 10 6 Inspection ... 12 7 Storage and transportation ... 14 8 Acceptance and installation ... 15 9 Daily inspection and maintenance ... 16 10 Technical management ... 18 Appendix A (Normative) Method for measuring the minimum thickness of shed and sheath ... 20 Appendix B (Informative) Recommendations for uniformity voltage fittings for 110 kV ~ 1000 kV composite insulators ... 22 Appendix C (Normative) Sampling acceptance test of composite insulators ... 24 Appendix D (Informative) Statistics of composite insulator damage (Failure) ... 26 Application guide of insulators for overhead lines with a nominal voltage over 1000V - Part 3: Composite insulator for a.c. system

1 Scope

This Part specifies the general technical requirements, selection principles, inspection, storage and transportation, acceptance and installation, daily inspection and maintenance, technical management of rod-shaped suspension composite insulators for AC overhead lines, which have a nominal voltage higher than 1000 V. This Part applies to composite insulators (referred to as composite insulators) for AC overhead power lines, which have a nominal voltage higher than 1000 V and a frequency of 50 Hz, as well as power plants and substations. The installation site is below 1000 m above sea level; the ambient temperature is between -40 °C ~ +40 °C. This Part includes requirements for selecting composite insulators according to specific operating conditions.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard. GB 311.1 Insulation co-ordination - Part 1: Definitions, principles and rules GB/T 311.2 Insulation co-ordination - Part 2: Application guide GB/T 4585 Artificial pollution tests on high-voltage insulators to be used on a.c. systems GB/T 19519 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V - Definitions, test methods and acceptance criteria GB/T 21421.1 Composite string insulator units for overhead lines with a nominal voltage greater than 1000 V - Part 1: Standard strength classes and end fittings GB/T 21421.2 Composite string insulator units for overhead lines with a nominal voltage greater than 1000 V - Part 2: Dimensional and characteristics GB/T 26218.1 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles GB/T 26218.2 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems GB 50545 Code for design of 110 kV ~ 750 kV overhead transmission line DL/T 368 The correction of high altitude on pollution external insulation for insulators used in transmission line DL/T 376 General technical requirements of silicone rubber insulation materials for composite insulators DL/T 741 Operating code for overhead transmission line DL/T 859 Artificial pollution tests on composite insulators used on high-voltage AC systems DL/T 1122 Technical guide of insulation coordination selection for overhead transmission line DL/T 1474 Hybridity measuring method of composite insulator for AC and DC overhead lines with a normal voltage greater than 1000 V JB/T 11219.1 End fitting for composite insulator with a high voltage overhead line. Part 1: End fitting for string insulator units

3 Terms and definitions

The following terms and definitions as defined in GB/T 19519 are applicable to this document. 3.1 Uniformity voltage fitting A device installed on the metal accessories, which can firstly improve the potential distribution of the composite insulator, protect the metal accessories, core rods and sheds from arc burns, secondly protect the connection areas of the metal accessories at both ends from damage to the sealing performance due to leakage tracking and erosion. The uniformity voltage fitting can be a uniformity ring, a uniformity arc starter ring or a semiconductor polymer device. 3.2 level of the composite insulator after installing the designed uniformity volage fitting shall not exceed 500 μV, at the specified 1.1 times the maximum operating phase voltage ( , where Um is the maximum operating voltage). 4.6.3 Artificial pollution power frequency withstanding performance Composite insulators shall meet the requirements of artificial pollution power frequency withstanding voltage test. A test voltage of is applied to the composite insulator, to withstand the given test salt density (SDD) and ash density (NSDD). The test procedure and criteria are carried out in accordance with GB/T 4585 and DL/T 859. 4.6.4 Power frequency arc performance Composite insulators shall meet the requirements of power frequency arc test. The design of the end accessories of composite insulators shall take into account the influence of arc. The short-circuit current and duration may cause damage to the end accessories, core rods, sheds; appropriate arc protection devices shall be designed. 4.7 Mechanical properties 4.7.1 Rated mechanical tensile load level The rated mechanical tensile load of composite insulators should be selected from the following levels: 70, 100 (120), 160, 210, 300, 400 (420) kN, 530 (550) kN. The strength grades outside the brackets shall be preferred. 4.7.2 Test load For newly put into operation composite insulators which have voltage levels of 330 kV and above, the average value of the mechanical destructive load minus 3 times the standard deviation shall not be less than the rated mechanical tensile load (SML). Note: For special projects, for example, composite insulators with strength grades of 300 kN and above used in 750 kV and above UHV projects should also withstand for 24h without damage under 1.2 SML. If the composite insulator is subjected to obvious compression, torsion, bending and other forces during use, the test method and test load shall be determined by negotiation between the supplier and the buyer.

5 Selection principles

5.1 General principles In the newly-built, expanded, rebuilt power transmission and transformation projects, the selection of composite insulators shall follow the principle of "mature technology, advanced process, reliable quality and operating experience". Before new products are used in batches, they must pass the type-finalization test; the trial operation time shall not be less than 1 year. The annual damage rate of operating composite insulators shall be less than 0.05%. 5.2 Unified specific creepage distance (USCD) and creepage factor Under general regional environmental conditions, the unified specific creepage distance (USCD) and creepage factor of composite insulators shall meet the requirements of GB/T 26218.1, GB/T 26218.2, DL/T 1122. For composite insulators used in special areas (such as high dust pollution areas, heavy pollution areas, heavy ice areas, etc.), if they are restricted by conditions such as structural height, the creepage factor (CF) can be determined by negotiation between the supplier and the buyer. 5.3 Uniformity voltage fitting a) The uniformity voltage fitting shall be designed to control the field strength at the end of the composite insulator within 4 kV/cm. It can be appropriately relaxed in special circumstances, but the maximum shall not exceed 5 kV/cm. Note: The field strength at the end of 1000 kV UHV composite insulators should be controlled within 5 kV/cm. b) For composite insulators with double-section structure, the middle connection part shall be equipped with a uniformity voltage shielding device that meets the relevant technical requirements of field strength control and anti-corona. c) The material of the uniformity voltage fitting should be aluminum alloy; it shall have sufficient mechanical strength. The pipe diameter, ring diameter, shielding depth of the uniformity voltage ring shall meet the relevant technical requirements of field strength control and anti-corona. d) The uniformity voltage fittings at the high-voltage end and the grounding end shall meet the requirements of the power frequency arc for composite insulators. e) When designing the uniformity voltage fitting, the installation position of the uniformity voltage fitting shall be unique. f) Whether to use the bird-proof uniformity voltage fitting is determined by the purchaser. g) Composite insulators with voltage levels of 110 kV and above shall be equipped checked for obvious signs of extrusion or damage. Store after the outer packaging is qualified. 7.1.2 Warehouse storage Composite insulators shall be stored in a dry and ventilated warehouse, to prevent damage caused by external forces such as water immersion and rat bites. It is prohibited to directly press heavy objects on the composite insulators or stack objects with sharp edges, to avoid deformation of the shed or mechanical damage. The stacking height of the packaging shall meet the requirements of the manufacturer and should not exceed 8 layers. 7.1.3 Outdoor storage In addition to meeting the above requirements, outdoor storage shall also take rain protection measures. 7.2 Transportation 7.2.1 General requirements The transportation specified in this Part refers to the transportation of composite insulators from the storage location to the installation site. Transportation and handling must be carried out when the packaging is intact. 7.2.2 Automobile transportation When using automobile transportation, the stacking of composite insulator packaging boxes (tubes) shall meet the above provisions of this Part. It is strictly forbidden to drag or throw during unloading, to ensure that the packaging boxes (tubes) land smoothly. 7.2.3 Manual handling When carrying a long (more than 4 m) packaging box (tube) containing composite insulators, it shall be carried by 3 or more people manually according to the position marked on the outer packaging. For long composite insulators, measures shall be taken to avoid damage to the composite insulators.

8 Acceptance and installation

8.1 Acceptance 8.1.1 Acceptance content The acceptance content before installation of composite insulators generally includes: a) Factory certificate; b) Consistency between packing list and accessories; c) Installation instructions; d) Locking pin; e) Contents specified in the contract. 8.1.2 Appearance inspection Check whether the outer packaging is intact; check the specifications and models; remove the outer packaging on site to check the appearance of the composite insulator. The appearance of the composite insulator shall comply with the requirements of GB/T 19519. If it is found that it does not meet the requirements or the shed has permanent deformation that reduces the shed spacing by more than 1/3, it should not be used. Composite insulators with torn sheds, damaged sheaths or damaged end seals shall not be used. 8.1.3 Acceptance test The acceptance test shall meet the requirements of Appendix C of this Part. 8.2 Installation precautions a) Handle with care; do not throw; avoid collision and friction with sharp objects. b) When lifting, the rope knot shall be tied on the metal accessories; it is forbidden to tie it directly on the shed. c) It is forbidden to step on the shed of composite insulators. d) Correctly install the uniformity voltage fitting; pay attention to install it in place; do not install it upside down; carefully adjust the ring surface to be perpendicular to the axis of the composite insulator. For open-type uniformity voltage fittings, pay attention to the same opening direction at both ends. e) For composite insulators used in areas where bird pecking occurs frequently, bird pecking protection measures shall be taken before live operation.

9 Daily inspection and maintenance

9.1 Daily inspection For composite insulators that have been in operation, daily inspections, pole climbing inspections, regular monitoring shall be carried out in accordance with the provisions of DL/T 741. The inspection contents shall include: e) When the pole or tower is applied with anti-rust paint, the composite insulator shall be covered, to prevent the paint from dripping onto the surface of the composite insulator; f) Special maintenance measures shall be taken for special dirty areas; g) When the hydrophobicity of the composite insulator surface has not disappeared permanently and no obvious discharge occurs in rainy and foggy weather, it can continue to be used. 9.3.1.2 If any of the following conditions occur in the composite insulator, it shall be replaced: a) The shed becomes embrittled (the shed cracks when folded); b) The hydrophobicity drops to HC6 or disappears permanently; c) The sheath is damaged and endangers the core rod; d) The shed is damaged in large quantities (more than 1/4 of the shed); e) The shed and sheath are severely burned; f) The sealing of the connection parts of the composite insulator fails, cracks, slips; g) The composite insulator does not meet the safety operation requirements after the testing items are tested; h) The infrared temperature measurement is abnormal. 9.3.2 Operation statistics An operation file shall be established for each batch of composite insulators; the flashover accidents and quality problems of the composite insulators shall be classified and counted. The statistical table is as shown in Appendix D.

10 Technical management

10.1 Establishment of files The operating organization shall establish equipment files and conduct technical management, in accordance with the provisions of DL/T 741. The archive content includes: a) Composite insulator manufacturer, production date, specifications, models, main technical parameters, grid operation time, line name, tower number, phase, operating environment, inspection records, regular inspection records, test ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of DL/T 1000.3-2015 be delivered?

Answer: The full copy PDF of English version of DL/T 1000.3-2015 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of DL/T 1000.3-2015_English with my colleagues?

Answer: Yes. The purchased PDF of DL/T 1000.3-2015_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- DL/T 1000.3-2015 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of DL/T 1000.3-2015?

A step-by-step guide to download PDF of DL/T 1000.3-2015_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "DL/T 1000.3-2015".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9