HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (9 Nov 2024)

YY/T 0719.8-2019 Related PDF English

YY/T 0719.8-2019 (YY/T0719.8-2019, YYT 0719.8-2019, YYT0719.8-2019) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
YY/T 0719.8-2019English190 Add to Cart 0-9 seconds. Auto delivery. Ophthalmic optics -- Contact lens care products -- Prat 8: Test method for detergent YY/T 0719.8-2019 Valid YYT 0719.8-2019
Buy with any currencies (Euro, JPY, KRW...): YY/T 0719.8-2019    Preview this PDF: YY/T 0719.8-2019



YY/T 0719.8-2019 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.70 C 40 Ophthalmic optics - Contact lens care products - Part 8: Test method for detergent ISSUED ON: OCTOBER 23, 2019 IMPLEMENTED ON: OCTOBER 01, 2020 Issued by: China Food and Drug Administration Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 General rule ... 4  4 Test method ... 4  5 Test report ... 8  Annex A (informative) Typical liquid chromatogram of poloxamer ... 10  Ophthalmic optics - Contact lens care products - Part 8: Test method for detergent 1 Scope This Part of YY/T 0719 specifies the test method to determine the content of Poloxamer or epoxy ethylene hydrogenated castor oil as active ingredient in contact lens care products (hereinafter referred to as care products). This Part is applicable to care products that the active ingredient of the detergent is poloxamer or epoxy ethylene hydrogenated castor oil. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682, Water for analytical laboratory use - Specification and test methods 3 General rule The test method specified in this Part shall be carried out at room temperature, that is, 10°C~30°C. Unless otherwise specified, all reagents used are analytical reagents. The experimental water shall meet the requirements for grade two water specified in GB/T 6682. 4 Test method 4.1 Poloxamer 4.1.1 Gel chromatography 4.1.1.1 Test principle Poloxamer is a polyoxyethylene polyoxypropylene ether block copolymer. It is a class of polymer nonionic surfactants. The commonly used models in care products are poloxamer 188 and poloxamer 407. This method uses a b) Column temperature: 30°C; c) Refractive index detector, temperature is 30°C; d) Mobile phase: sodium dihydrogen phosphate solution (0.02mol/L): acetonitrile=7:3; e) Flow rate: 0.7mL/min; f) Injection volume: 50μL. 4.1.1.7 Determination and result analysis Respectively conduct analysis determination to standard solution and sample. Establish standard working curve and regression equation. Calculate the content of poloxamer in the sample. See Annex A for typical chromatograms. 4.1.2 Ultraviolet-visible spectrophotometry 4.1.2.1 Test principle According to the characteristic that hydroxypropyl methylcellulose has the ability to form a gel after heating in an aqueous solution, and then dissolve after cooling, pre-process the care solution to remove HPMC. Use ultraviolet-visible spectrophotometry that takes iodine-potassium iodide solution as the developer to determine the poloxamer content in nursing solution in the care solution. 4.1.2.2 Instruments and reagents 4.1.2.2.1 Reagents: iodine, potassium iodide. 4.1.2.2.2 Reference substance: poloxamer. 4.1.2.2.3 Instruments: UV-visible spectrophotometer, 1cm quartz cuvette; analytical balance with accuracy of 0.1mg. 4.1.2.3 Solution preparation Poloxamer standard stock solution (0.1mg/mL): Accurately weigh 0.5g of poloxamer for reference that has been dried to constant weight, to the nearest of 0.1mg. Use pure water to conduct ultrasonic dissolution and set volume into a 50mL volumetric flask. Shake well. Then accurately pipette 1mLof the above solution to a 100mL volumetric flask. Use pure water to set volume to the scale. Shake well to obtain the solution. Iodine-potassium iodide color developing solution: Weigh 2.0g of potassium iodide. Add an appropriate amount of water to make it dissolved. Then accurately add 1.0g of iodine to make it dissolved. Transfer to a 100mL analytical balance with accuracy of 0.1mg. 4.2.3 Solution preparation Epoxyethylene hydrogenated castor oil standard stock solution (0.2mg/mL): Weigh 0.1g of RH40 reference substance, to the nearest of 0.1mg. Use pure water to dissolve. Set volume to a 50mL volumetric flask. Shake well. Then accurately pipette 1mLof the above solution to a 10mL volumetric flask. Use pure water to set volume to the scale. Shake well to obtain 0.2mg/mL standard stock solution. Iodine-potassium iodide color developing solution: Weigh 2.0g of potassium iodide. Add an appropriate amount of water to make it dissolved. Then accurately add 1.0g of iodine to make it dissolved. Transfer to a 100mL volumetric flask. Add water to dilute to the scale. Shake well to obtain the solution (this product shall be kept away from light). 4.2.4 Preparation of standard solution Respectively pipette 1.0mL~3.0mL of epoxy ethylene hydrogenated castor oil standard stock solution to 10mL volumetric flasks. Set volume and shake well. Add 0.25mL of mixed color developing solution. Shake well to obtain a series of standard solutions with a concentration of 20×10-6~60×10-6. At least 5 concentration points shall be selected. Use the same method and take pure water for blank. 4.2.5 Sample processing Precisely pipette the right amount of sample. Dilute to a concentration about 40×10-6. Then accurately add 0.25mL of iodine-potassium iodide color developing solution. Shake well. 4.2.6 Determination and result analysis After standard and sample are placed for 2h, at 500nm, determine the absorbance. Perform parallel determination of 3 sets of data. Establish working standard curve and regression equation. Calculate the content of epoxy ethylene hydrogenated castor oil in the sample according to the standard curve. 5 Test report The test report shall at least contain the following information: a) Information about test sample; b) Reference number to this Part; ......

BASIC DATA
Standard ID YY/T 0719.8-2019 (YY/T0719.8-2019)
Description (Translated English) Ophthalmic optics -- Contact lens care products -- Prat 8: Test method for detergent
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C40
Classification of International Standard 11.040.70
Word Count Estimation 7,796
Date of Issue 2019
Date of Implementation 2020-10-01
Summary This standard specifies the test method for the determination of the active ingredient cleaning agent in contact lens care products (referred to as care products) as poloxamer or ethylene oxide hydrogenated castor oil. This standard applies to care products containing poloxamer or ethylene oxide hydrogenated castor oil as the active ingredient of the cleaning agent.