YY 0068.2-2008 related PDF English

YY 0068.2-2008 (YY0068.2-2008) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
YY 0068.2-2008English125 Add to Cart 0-9 seconds. Auto delivery. Medical endoscopes. Rigid endoscope. Part 2: Mechanical properties and test methods YY 0068.2-2008 Obsolete YY 0068.2-2008
Buy with any currencies (Euro, JPY, KRW...): YY 0068.2-2008    Preview this PDF: YY 0068.2-2008



YY 0068.2-2008: PDF in English
YY 0068.2-2008 YY ICS 11.040 C 40 Pharmaceutical Industry Standard of the People’s Republic of China Partially replacing YY 0068-1992 Medical endoscopes – Rigid endoscope – Part 2. Mechanical properties and test methods ISSUED ON. OCTOBER 17, 2008 IMPLEMENTED ON. JUNE 1, 2010 Issued by. China Food and Drug Administration Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions ... 5  4 Requirements ... 7  5 Test methods ... 10  Foreword The clause 5 of this Part are recommended. YY 0068 Medical endoscopes – Rigid endoscope is divided into four parts. — Part 1. Optical properties and test methods; — Part 2. Mechanical properties and test methods; — Part 3. Marking and instruction manual; — Part 4. Fundamental requirement. This Part is the Part 2 of YY 0068. This Part corresponds to ISO 8600-1.2005 Optics and photonics – Medical endoscopes and endotherapy devices – Part 1. General requirements, and ISO 8600-4.1997 Optics and optical instruments – Medical endoscopes and certain accessories – Part 4. Determination of maximum width of insertion portion. Furthermore, this Part is not equivalent to the degree of consistency specified in the ISO 8600-1.2005 and ISO 8600-4.1997. The terms and definitions of this Part are consistent with the concepts described in ISO 8600-6.2005 Optics and photonics – Medical endoscopes and endotherapy devices – Part 6. Vocabulary. The differences between this Part and the parts of the ISO 8600 are as follows. — DIVIDE the parts of the standard according to the characteristics of rigid endoscopes described in this Standard; — SUPPLEMENT the contents of working length, dimensions of the eyepiece cover, coordination, encapsulation, strength and stiffness, connection, and external surface quality of the insertion portion. This Part replaces the requirements and relevant test methods specified in the Sections 4.3, 4.6, 4.7, 4.8 and 4.11 of the YY 0068-1992. From the date of the implementation of this Part, the replaced clauses in the YY 0068-1992 will be abolished at the same time. This Part shall be used together with GB 11244-2005. The relevant requirements are the supplement to the relevant requirements specified in the GB 11244-2005. This Part was proposed by and shall be under the jurisdiction of the Technical Medical endoscopes – Rigid endoscope – Part 2. Mechanical properties and test methods 1 Scope This Part of YY 0068 specifies the mechanical property requirements and test methods of the rigid endoscopes. This Part applies to the rigid endoscopes for medical purposes. 2 Normative references The provisions in the following documents become the provisions of this Part through reference in this Part of the YY 0068. For dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Part. However, parties who reach an agreement based on this Part are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest versions apply to this Part. YY 0068.1 Medical endoscopes – Rigid endoscope – Part 1. Optical properties and test methods 3 Terms and definitions The terms and definitions established in the YY 0068.1 and the following ones are applicable to this Part of the YY 0068. 3.1 Endotherapy device It refers to the medical device entering into the human body’s natural orifice or surgical incision via the channel which is the same with or different from that of the endoscope during the endoscopic surgery, for the purposes of examination, diagnosis or treatment. Note 1. The endotherapy devices include some devices guiding the insertion of the endoscopes or endotherapy devices, such as catheter, trocar or sliding pipe. The endotherapy devices also include the devices entering from different human bodies’ incisions which are different from those of the endoscope, and used under the observation of the endoscope for security reasons. Note 2. The term “endoscopic accessories” is used in the Section 2.1.102 of the GB 9706.19-2000. 4.3 Encapsulation 4.3.1 Fog layer For the endoscopes containing optical elements, CLEAN and DRY the sealed interior. After the sudden change test from low temperature to high temperature, there shall be no blurry field of view. 4.3.2 Encapsulation reliability The endoscopes containing optical elements shall be able to bear the following encapsulation test without losing efficiency. 1) CONDUCT hydrostatic test for 12h at 1m under water; 2) REPEAT to conduct the test for 20 times according to the sterilization or disinfection methods specified by the manufacturer. Note. Section 4.3.2 b) of this Part does not apply to the disposable endoscopes. 4.4 Strength and stiffness If the dimensions of the cross section of the endoscope’s insertion portion is too small, or the slenderness ratio is too large, and thus it is easy to be damaged, the manufacturer shall give a warning description in the accompanying files. In the meantime, GIVE an indication of the vulnerable and frangible portions, and CLAIM the maximum bearable force or torque. CONDUCT the test to verify this force or torque. The test force or torque shall not be less than the declared value. If the endoscope’s insertion portion allows to be bent moderately, the manufacturer shall describe the allowable bending portion, maximum deflection, force under the maximum deflection, and test methods in the accompanying files. Note. The applicability determination depends on the continuous clinical feedback, or manufacturer’s self- declaration, or senior’s evaluation. 4.5 Connection For the connecting portions constituted by the endoscopes, if using the tight fit method for connection, there shall be no visible gaps at the fitting locations; if using the welding method for connection, there shall be no uneven bumps, de- soldering, surfacing, or significant pitting at the welds; if using the gluing method for connection, there shall be no overflow or apparent gel at the gluing locations, and there shall be no glue marks on other portions. 5.2 Coordination inspection 5.2.1 Tests for locking, insertion and demolition 5.2.1.1 Equipment Standard tension meter, or other equivalent tools. The minimum reading of the measuring tool shall be greater than 10% of the required minimum reading. 5.2.1.2 Environmental conditions At room temperature. 5.2.1.3 Procedures 5.2.1.3.1 USE a special fixture or soft noose to connect the terminal of the eyepiece cover or the leading-out terminal of the endoscope. 5.2.1.3.2 The measurement procedures shall be in accordance with the routine method. The test’s point of action shall be located on the mechanical axis or extension line of the specimen. The force direction shall parallel to this mechanical axis. 5.2.2 Tests for positioning and coordination Environmental conditions. at room temperature. VERIFY the test described in the Section 4.2.2 a) via the operations coordinated with the inspection. LOCK the coordination BETWEEN endoscope AND sheath as well as BETWEEN endoscope AND bridge and sheath. CONDUCT the test described in the Section 4.2.2 b) afterwards. USE a casing pipe to tighten the distal sheath. SEAL at the juncture. USE a rubber hose to connect the casing head with the water source whose differential pressure is not lower than 1m water column. TURN on the water column. LAST for 1min. OBSERVE the leakage situation within 1min at the location where the endoscope coordinates with the sheath, or with the bridge and sheath. 5.3 Encapsulation inspection 5.3.1 Fog layer test 5.3.1.1 Equipment One temperature regulating water bath. The maximum controllable water and above and whose steam pressure can be up to more than 200kPa. 5.3.2.1.2 One sink with the depth of 1m. The dimensions of the bottom surface shall be able to ensure that all the test specimens can lie flat. 5.3.2.2 Environmental conditions At room temperature within the range of 5°C to 30°C. 5.3.2.3 Procedures 5.3.2.3.1 Repeatedly CONDUCT the test for 20 times according to the sterilization or disinfection methods specified by the manufacturer. 5.3.2.3.2 SOAK in the sink with the depth of 1m for 12h. 5.3.2.3.3 TAKE out the endoscopes. CLEAN the surfaces according to the routine method. 5.3.2.3.4 OBSERVE the optical system. 5.4 Strength and stiffness tests 5.4.1 Strength test CONDUCT the maximum force or torque test according to the methods indicated by the manufacturer. If the manufacturer indicates no methods, SELECT the point of force application and the direction according to the worst conditions. 5.4.2 Stiffness test CONDUCT the maximum deflection and force tests according to the methods indicated by the manufacturer. If the manufacturer indicates no methods, APPLY force to the direction perpendicular to the initial mechanical axis at the farthest end according to the way of cantilever beam, so as to conduct the maximum deflection test. 5.5 Connection inspection USE visual observation combined with the hand-feeling inspection for verification. 5.6 External surface quality of the insertion portion USE visual ... ......

BASIC DATA
Standard ID YY 0068.2-2008 (YY0068.2-2008)
Description (Translated English) Medical endoscopes. Rigid endoscope. Part 2: Mechanical properties and test methods
Sector / Industry Medical Device & Pharmaceutical Industry Standard
Classification of Chinese Standard C40
Classification of International Standard 11.040
Word Count Estimation 8,839
Date of Issue 2008-10-17
Date of Implementation 2010-06-01
Older Standard (superseded by this standard) YY 0068-1992
Quoted Standard YY 0068.1
Adopted Standard ISO 8600-1-2005, NEQ; ISO 8600-4-1997, NEQ; ISO 8600-6-2005, NEQ
Drafting Organization Hangzhou, the State Food and Drug Administration Medical Device Quality Supervision and Inspection Center
Administrative Organization Optics and optical instruments National Standardization Technical Committee
Regulation (derived from) SFDA [2008] No. 605
Proposing organization Optics and optical instruments National Standardization Technical Committee medical optical instruments and Technical Committee (SAC/TC 103/SC 1)
Issuing agency(ies) China Food and Drug Administration
Summary This standard specifies the rigid endoscope mechanical performance requirements, test methods. This standard applies to medical purposes rigid endoscopes.