HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (29 Sep 2024)

YS/T 1028.5-2015 related PDF English

YS/T 1028.5-2015 (YS/T1028.5-2015, YST 1028.5-2015, YST1028.5-2015) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
YS/T 1028.5-2015English175 Add to Cart 0-9 seconds. Auto delivery. Methods for chemical analysis of lithium iron phosphate. Part 5: Determination of calcium、magnesium、zinc、copper、lead、chromium、sodium、aluminium、nickel、cobalt、manganese content. Inductively coupled plasma atomic emission spectrometry YS/T 1028.5-2015 YST 1028.5-2015
Buy with any currencies (Euro, JPY, KRW...): YS/T 1028.5-2015    Preview this PDF: YS/T 1028.5-2015



YS/T 1028.5-2015: PDF in English (YST 1028.5-2015)
YS/T 1028.5-2015 YS NONFERROUS INDUSTRY STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA ICS 77.120.99 H 71 Methods for chemical analysis of lithium iron phosphate - Part 5: Determination of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, manganese content - Inductively coupled plasma atomic emission spectrometry ISSUED ON: APRIL 30, 2015 IMPLEMENTED ON: OCTOBER 1, 2015 Issued by: Ministry of Industry and Information Technology of PRC Table of Contents Foreword ... 3 1 Scope ... 4 2 Method summary ... 4 3 Reagents ... 4 4 Instruments ... 5 5 Samples ... 6 6 Analysis steps ... 6 7 Calculation ... 7 8 Precision... 7 9 Test report ... 9 Methods for chemical analysis of lithium iron phosphate - Part 5: Determination of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, manganese content - Inductively coupled plasma atomic emission spectrometry 1 Scope This part of YS/T 1028 specifies the determination method of the content of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium iron phosphate. This part applies to the determination of the content of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium iron phosphate. The measurement range is shown in Table 1. 2 Method summary The sample is dissolved with hydrochloric acid, the carbon in it is filtered out, and the element to be measured is measured by using an inductively coupled plasma atomic emission spectrometer. 3 Reagents 3.1 Hydrochloric acid (guaranteed reagent, ρ≈1.19 g/mL). 5 Samples The particle size of the sample shall not be larger than 0.10 mm. 6 Analysis steps 6.1 Specimen Weigh the sample (Chapter 5) according to Table 3, accurate to 0.0001 g. 6.2 Number of measurements Weigh 2 specimens, conduct parallel measurements, and take the average value. 6.3 Blank test Do a blank test along with the specimen. 6.4 Specimen handling Place the specimen (6.1) in a 100 mL quartz beaker, moisten it with a small amount of water, add 20 mL of hydrochloric acid (3.2), cover it with a watch glass, and heat it at low temperature to a slight boil in a fume hood for 3 ~ 5 minutes; blow wash the watch glass with a small amount of water, filter with filter paper after cooling, and wash the filter residue with water 5 ~ 7 times; transfer the filtrate into a volumetric flask according to the corresponding test solution volume in Table 3, dilute with water to the mark, mix well for later use; at the same time, make a reagent blank. 6.5 Drawing of working curve Accurately pipette 0 mL, 0.40 mL, 1.00 mL, 2.00 mL, 5.00 mL, 10.00 mL, and 20.00 mL of mixed standard solution (3.5) into 100 mL volumetric flasks, dilute to the mark with hydrochloric acid (3.3), and mix well. On the ICP spectrometer with optimized parameters, measure the spectral intensity of each element such as calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, and manganese, and draw a working curve. 6.6 Determination On the ICP spectrometer with optimized parameters, measure the spectral intensity of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, and manganese in the blank solution and sample solution, and obtain the concentrations of corresponding components from the working curve. For the sample whose element content exceeds the concentration range of the working curve, it can be measured after quantitative dilution. 7 Calculation The content of the element to be measured is calculated based on the mass fraction wx of the element to be measured, and the value is expressed in % and calculated according to formula (1): where: ρ -- The concentration of the measured element in the test solution obtained from the working curve, in micrograms per milliliter (μg/mL); ρ0 -- The concentration of the measured element in the blank solution obtained from the working curve, in micrograms per milliliter (μg/mL); m -- The mass of the specimen, in grams (g); V -- The volume of the test solution, in milliliters (mL). The calculation results are rounded to two decimal places. 8 Precision 8.1 Repeatability The measured values of two independent test results obtained under repeatability conditions are within the average value range given below; the absolute difference between the two test results does not exceed the repeatability limit (r), the probability of exceeding the repeatability limit (r) does not exceed 5%, and the repeatability limit (r) is obtained by linear interpolation according to the data in Table 4: ......

BASIC DATA
Standard ID YS/T 1028.5-2015 (YS/T 1028.5-2015)
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H71
Classification of International Standard 77.120.99
Word Count Estimation 7,768
Date of Issue 2015-04-30
Date of Implementation 2015-10-01
Drafting Organization Bump circulation Guangdong Science and Technology Co., Ltd.
Administrative Organization National non-ferrous metals Standardization Technical Committee
Regulation (derived from) Ministry of Industry and Information Technology Announcement (2015 No. 28)
Proposing organization National Non-Ferrous Metals Standardization Technical Committee (SAC/TC 243)
Issuing agency(ies) Ministry of Industry and Information Technology of the People's Republic of China
Summary This Standard specifies the calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminum, nickel, cobalt, manganese determination of the amount of lithium iron phosphate. This applies to all points calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminum, nickel, cobalt, manganese contents of lithium iron phosphate. Determination of the range in Table 1.