HOME   Cart   Quotation   About-Us Tax PDFs Standard-List
Powered by Google-Search & Google-Books www.ChineseStandard.net Database: 189760 (24 Feb 2024)

TSG T7007-2022 (TSGT7007-2022)

Chinese standards (related to): 'TSG T7007-2022'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusGoogle Book
TSG T7007-2022English3699 Add to Cart 19 days Regulation for Type Test of Lifts TSG T7007-2022 Valid TSG T7007-2022
TSG T7007-2016EnglishRFQ ASK 15 days Regulation for Type Test of Lifts TSG T7007-2016 Obsolete TSG T7007-2016


   
BASIC DATA
Standard ID TSG T7007-2022 (TSGT7007-2022)
Description (Translated English) Regulation for Type Test of Lifts
Sector / Industry Special Equipment Industry Standard
Word Count Estimation 211,255
Date of Issue 2022-01-25
Date of Implementation 2022-07-01
Summary This standard applies to the type test of the products listed in the "Catalogue of Elevator Type Test Products" (see Appendix A, hereinafter referred to as "Catalogue").


TSG T7007-2022: PDF in English
TS GT7007-2022
TS G T7007-2022 English name. Regulation for Type Test of Lifts
TS G Special Equipment Safety Technical Specification TS G T7007-2022
Released by the State Administration for Market Regulation
Elevator Type Test Rules
Special equipment safety technical specification TS G T7007-2022
1.3 Scope of application
This rule applies to the products listed in the "Catalogue of Elevator Type Test Products" (see Appendix A, hereinafter referred to as "Catalogue")
Product type test.
If the products listed in the "Catalogue" meet any of the following conditions, type tests shall be carried out.
(1) The manufacturing entity manufactures for the first time or overseas manufacturing is put into use for the first time in China;
(2) The main parameters of the product exceed the scope of application;
(3) The product configuration specified in the product type test requirements is changed;
(4) In case of any other impact on product safety performance, the State Administration for Market Regulation (hereinafter referred to as the State Administration for Market Regulation)
Bureau) put forward the type test requirements.
2 Procedures and Requirements
2.1 General requirements
2.1.1 Type test site
2.1.1.1 Machine
The type test of the whole machine of the elevator (hereinafter referred to as the whole machine test) shall be carried out by the manufacturer or the type test institution.
It is carried out in the well inspection road (test site).
TS G T7007-2022 Safety Technical Specifications for Special Equipment
The elevators listed in the "Superconventional Elevator Parameter Table" (see Appendix B) or the elevators with special structures used only for a single project
For elevators, when it is really necessary to carry out the whole machine test on the site of use, the unit that applies for the type test (domestic refers to the manufacturing unit, and the domestic
Foreign refers to the manufacturing unit or its authorized agency in China, hereinafter collectively referred to as the applicant) shall submit to the user
place expressly, and after obtaining the written consent of the user unit, submit an application to the type test institution, and the type test institution
After written confirmation, hold the "Special Equipment Production License" or "Special Equipment Administrative Licensing Acceptance Decision" (repeated
stamped with the official seal of the application unit), and the construction notice shall be handled in accordance with the regulations before one unit can be installed on the site for use
The complete machine for the type test (the complete machine used for the type test is hereinafter referred to as the prototype). After the type test is completed, the manufacturer shall
When it is fully inspected, replace worn parts and re-commissioning.
Prototype type test and performance test in the process of installation supervision and inspection can be carried out at the same time, and the data can be shared. install
The installation supervision inspection report shall be issued after the type test is passed.
2.1.1.2 Safety protection devices and main components
The type test of safety protection devices and main components (hereinafter collectively referred to as samples) shall be carried out in the type test institution.
OK. If the sample really needs to be tested in combination with the whole machine or in the test site of the manufacturer, it shall be included in the type test report.
The reason is stated in the report.
2.1.2 Type test site conditions
The following test conditions shall be met when carrying out the type test.
(1) When the whole machine is tested, the environmental conditions such as temperature, humidity and power supply system voltage of the working place of the prototype meet the production requirements.
Relevant regulations of product standards; the test site is clean and tidy, and there are no items or facilities that affect the test, and the placement indicates that the site is normal.
warning signs that tests are in progress;
(2) During the sample test, the environmental conditions such as temperature, humidity and power supply system voltage of the sample test site meet the requirements of the product.
Relevant regulations of product standards.
2.1.3 Obligations of the manufacturer and the applicant
Before the type test, the manufacturer shall conduct a comprehensive test verification of the product to confirm that the product safety and reliability meet the
Comply with relevant safety technical specification requirements.
The applicant unit shall be responsible for the authenticity of the type test prototype (sample) and the relevant materials provided.
During the complete machine test, the applicant unit shall assign relevant professionals to the test site to cooperate with the test work.
2.1.4 Responsibilities of Type Test Institutions
2.1.4.1 Organization qualification and personnel qualification
The type test institution shall be approved by the State Administration for Market Regulation, and the type test personnel shall have corresponding special equipment.
Qualifications for type test personnel.
Special equipment safety technical specification TS G T7007-2022
2.1.4.2 Job Requirements
(1) The type test institution shall, within the scope of its approval, conduct type tests in accordance with the requirements of this rule;
During the implementation of the type test, if any abnormality or special situation is found, the test personnel can refer to the relevant standards to increase the test
Inspection items, but it should be approved by the applicant unit and approved by the technical director of the institution;
(2) Type test prototype (sample) and related information provided involve commercial or technical secrets, type test
The institution shall keep it confidential in accordance with the requirements of the applicant unit;
(3) The testing equipment and measuring instruments used by the type test institution for the type test of the elevator shall be in accordance with
Relevant regulations have passed the verification or calibration and are within the validity period.
2.1.5 Labor protection and safety
During the test, the type test personnel and cooperating personnel shall be equipped with and wear necessary protective equipment for the test operation.
products, and follow safe work procedures.
When the test conditions are not met or continuing the test may cause safety and health damage, the test personnel should stop
test, and explain the reason in writing to the applicant unit.
2.2 Type test procedure
Elevator type test work procedures, including application, sampling, technical data review, inspection and testing, issuing
Reports and certificates, information releases.
2.2.1 Application
When applying to the type testing institution, the applicant unit shall submit the following materials.
(1) "Application Form for Elevator Type Test" (see Appendix C for the format);
(2) Business qualification certification documents and authorization certification documents (if the applicant is an authorized agency);
(3) The technical data provided in the product type test requirements.
The applicant unit shall propose the applicable scope of the type test certificate within the scope of application specified in the product type test requirements.
Apply for the scope of use, and submit the relevant technical information on the differences between the applicable product and the test prototype (sample).
After receiving the application materials from the applicant unit, the type test institution shall confirm the materials submitted by it, and
And make a decision on whether to accept the application within 10 working days, and give a written reply at the same time. Incomplete submission
If so, it shall be notified once and for all to make corrections.
2.2.2 Sampling
The samples shall be randomly selected by the type testing agency from the products that have passed the self-inspection in the applicant unit, and the details of the sampling shall be
For the requirements, see Appendix D "Elevator Safety Protection Devices and Main Components Type Test Sampling Requirements".
2.2.3 Review of technical data
The type test institution shall, in accordance with the requirements of Annex H to Annex AA of this rule, conduct technical tests submitted by the applicant unit
Technical data are reviewed.
TS G T7007-2022 Safety Technical Specifications for Special Equipment
2.2.4 Prototype (sample) inspection and test
The type test institution shall inspect the prototype (sample) in accordance with the requirements of Annex H to Annex AA of this regulation.
Check and test.
2.2.5 Issuance of reports and certificates
2.2.5.1 Records
During the test, the test personnel shall record the test conditions and test results of each item in detail. There are tests
Items with data requirements should record the measured data; items without test data requirements should be explained in simple words
Field trial status and results. If necessary, the test records can be another table or attached drawings.
The items and contents of the test records shall be complete and traceable. Its format is determined by the type test institute
It is formulated in a unified manner and officially released and used by this institution.
2.2.5.2 Conclusion Judgment
The conclusion of the type test shall be judged according to the following requirements.
(1) If all applicable items meet the requirements of this rule, it is judged as "qualified";
(2) When the prototype type test items are unqualified, the rectification shall be completed within 6 months, and the re-inspection shall comply with this regulation.
If it is required by the standard, it will be judged as "qualified"; if the rectification has not been completed within 6 months or after re-inspection after rectification, it still does not meet this requirement.
If required by the rules, it shall be judged as "unqualified";
(3) When the sample type test item is unqualified, it is judged as "unqualified"; among them, technical data review, etc.
In case of unqualification, it shall be dealt with in accordance with item (2) of this article.
2.2.5.3 Handling of unqualified
(1) When there are unqualified items in the type test, the type test personnel shall issue the "Elevator Type Test
Test Opinion Letter (hereinafter referred to as Type Test Opinion Letter, see Appendix E for the format);
(2) If the conclusion of the type test is unqualified, and the applicant needs to conduct the type test again, it shall submit
The testing agency submits an application.
2.2.5.4 Reports and certificates
After the type test is completed, the type test institution shall issue the "Special
Type test report (elevator) for this type of equipment (hereinafter referred to as type test report). Type test qualified, type test
The institution shall also issue the "Special Equipment Type Test Certificate (Elevator)" (hereinafter referred to as the Type Test Certificate).
The type test certificate should give the application according to the scope of application of the applicant and the review status of the applicable product technical data.
The scope of application determined by the situation.
The content and format of the type test report and type test certificate shall comply with Annex F and Annex G of this regulation,
And the corresponding type test requirements.
2.2.5.5 Result Objection Handling
After receiving the type test opinion, type test report or type test certificate, the applicant shall
If there is any objection to the results, a written opinion shall be submitted to the type testing agency within 15 working days.
Special equipment safety technical specification TS G T7007-2022
The agency shall reply in writing within 15 working days. If there are still objections to the reply of the type testing agency, the application
Units may appeal to the approval department of the type testing institution.
2.2.6 Information release
The type test institution shall, within 5 working days after issuing the type test report or certificate,
In accordance with the regulations on information management of equipment, the relevant data of type tests shall be input into the information management system of special equipment in a timely manner.
And be responsible for the authenticity and correctness of the uploaded data.
2.3 Consistency Check
After passing the first type test, the type test institution shall check the safety protection device (non-metal material, non-metallic material) every four years.
except for linear energy storage buffers) and main components for a consistency check.
The main contents of the consistency check are as follows.
(1) Whether the basic information of the product and its type test sample is consistent;
(2) Whether the main configuration of the product is consistent with that of the type test sample;
(3) Whether the main safety performance of the product is qualified.
The type test institution shall inspect and test the checked products in accordance with the corresponding product type test requirements.
Inspection, and update the type test certificate for products that pass the inspection conclusion.
If the consistency check finds that there is a problem with the main safety performance of the product, the type test institution shall report to the application in a timely manner.
Please ask the provincial special equipment safety supervision and management department where the unit is located.
The manufacturer of the complete elevator shall conduct quality control on the purchased safety protection devices and main components, and confirm
Consistency of product quality and safety performance with type test samples and results. For batch production, the product quality is greatly affected
The safety protection device and main components (such as non-metallic nonlinear energy storage buffer), the whole machine manufacturer should
Sampling tests shall be carried out in batches (at least one sample of each specification), and its safety performance shall not be lower than the requirements of this regulation.
2.4 Changes
When the name or address of the applicant unit and the overseas manufacturing unit changes, the applicant unit shall promptly submit the corresponding
The certification materials shall be submitted to the prototype test institution for change application, and the type test report shall be included in the type test report after confirmation by the type test institution.
Indicate the changes on the "Changes Page" of the website, and at the same time withdraw the prototype type test certificate and issue a new type test certificate
Certificate.
After the change is completed, the type test institution shall upload the change to the special equipment letter within 5 working days.
information management system.
TS G T7007-2022 Safety Technical Specifications for Special Equipment
3 by-laws
3.1 Dealing with relevant situations
If the applicant unit applies for cancellation by itself, or the applicant unit has one of the following circumstances, the type test institution shall
When the prototype type test report and type test certificate are withdrawn in time, and published on the special equipment information management system
Buqi related information.
(1) Providing false information and prototypes (samples);
(2) Forging or altering the type test report or type test certificate;
(3) Rejecting without justified reasons, or refusing to cooperate, delaying or hindering the consistency verification;
(4) The consistency check does not meet the requirements;
(5) Failure to complete the consistency check within the prescribed time limit due to its own reasons;
(6) Fatal accidents of passengers caused by manufacturing reasons;
(7) The reduction of product parameters and configurations causes the elevator not to comply with the scope of application of the type test certificate;
(8) Other violations of laws and regulations.
3.2 Right of interpretation
The State Administration for Market Regulation is responsible for interpreting these rules.
3.3 Implementation date
This rule will come into effect on July 1, 2022.