HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (6 Oct 2024)

JJG 291-2018 related PDF English

JJG 291-2018 (JJG291-2018) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
JJG 291-2018English439 Add to Cart 4 days Dissolved Oxygen Meters JJG 291-2018 Valid JJG 291-2018
JJG 291-2008English170 Add to Cart 0-9 seconds. Auto delivery. Verification regulation of dissolved oxygen meter with covered-membrane-electrode JJG 291-2008 Obsolete JJG 291-2008
JJG 291-1999English479 Add to Cart 4 days Verification Regulation of Film Electrode Dissolved Oxygen Meter JJG 291-1999 Obsolete JJG 291-1999
JJG 291-1982EnglishRFQ ASK 3 days (Chinese Industry Standard) JJG 291-1982 Obsolete JJG 291-1982



JJG 291-2018: PDF in English
JJG 291-2008 JJF National Metrology Technical Specifications of the People's Republic of China Dissolved Oxygen Meter with Covered-Membrane- Electrode ISSUED ON. DECEMBER 23, 2008 IMPLEMENTED ON. JUNE 23, 2009 Issued by. State Administration for Quality Supervision and Inspection and Quarantine Verification Regulation of Dissolved Oxygen Meter with Covered-Membrane-Electrode Replacing JJG 291-1999 This regulation was approved by General Administration of Quality Supervision, Inspection and Quarantine on December 23, 2008 and shall be implemented from June 23, 2009. Jurisdictional organization. National Technical Committee on Environmental Stoichiometry Drafting organization. Zhejiang Province Institute of Metrology This regulation is entrusted to and shall be responsibly interpreted by National Technical Committee on Environmental Stoichiometry. Drafter of this regulation. Zhang Yanqun (Zhejiang Province Institute of Metrology) Table of Contents 1 Scope ... 5  2 Overview ... 5  3 Requirements for metrological performance ... 5  4 General technical requirements ... 5  5 Measuring instrument control ... 6  Annex A Preparation of Water for Verification ... 13  Annex B Structural Drawing of Device for Verification Water Preparation ... 14  Annex C Saturation concentration table of oxygen in water with different temperatures  ... 15  Annex D Saturated Vapor Pressure of Pure Water at Different Temperatures... 16  Annex E Verification Record ... 17  Annex F Format of Verification Certificate and Note of Verification Result ... 19  (Inner Page) ... 19  Dissolved Oxygen Meter with Covered-Membrane-Electrode 1 Scope This regulation applies to initial verification, subsequent verification and in-use verification of laboratory-service and portable dissolved oxygen meters with covered-membrane-electrode (hereinafter referred to as the instrument) that have a measuring range of (0 ~ 20)mg/L. 2 Overview The instrument is used to measure concentration of constant dissolved oxygen meter (DO) in water. The instrument is composed of covered-membrane-oxygen electrode, electronic unit and displayer. 3 Requirements for metrological performance 3.1 Zero error Zero error of instrument shall not exceed 0.10 mg/L. 3.2 Response time Response time of instrument shall not exceed 60 s. 3.3 Dissolved oxygen concentration indication error Dissolved oxygen concentration indication error of instrument for initial verification shall not exceed ±0. 30 mg/L; indication error for subsequent verification shall not exceed ±0. 50 mg/L. 3.4 Repeatability Standard deviation of instrument for initial verification shall not exceed 0.15 mg/L; standard deviation for subsequent verification shall not exceed 0.20 mg/L. 3.5 Temperature indication error Temperature indication error of instrument shall not exceed ± 0. 5°C. 3.6 Salinity compensation error Salinity compensation error of instrument shall not exceed ± 2 %. 4 General technical requirements 4.1 Appearance 4.1.1 The instrument shall indicate the name of manufacturing company, model and manufacturing number; domestic instrument shall be marked with metering equipment referring to Annex D, in Pa. Take △c with maximum absolute value as dissolved oxygen concentration indication error. 5.3.7 Verification of repeatability 5.3.7.1 Verification of repeatability of instrument shall be carried out in saturated dissolved oxygen water that thermostatic water batch is close to the room temperature. 5.3.7.2 Measure table saturated dissolved oxygen water for continuous 6 times; record 5.3 Verification method 5.3.1 Appearance Check through vision or hand feeling according to requirements of 4.1. 5.3.2 Verification of insulation resistance The instrument is not connected to power source. Turn on the power switch. Connect one end of insulation resistance meter to the phase of instrument input terminal and neutral conjunction line, while connect the other end to protective earth terminal (or shell) of the instrument. Apply test voltage of 500 V and continue for 5 s; measure insulation resistance. 5.3.3 Verification of dielectric strength The instrument is not connected to power source. Turn on the power switch. Connect two measuring lines of dielectric strength tester to phase of power input terminal, central conjunction line and ground terminal (or shell). Apply test voltage of 1 500 V; set leak current to be 5 mA and lifting time to be (5s to 20)s; keep for 1 min, and then lower the voltage to 0 V stably. There shall be no breakdown and arcing phenomena during the test process. 5.3.4 Verification zero error 5.3.4.1 Calibrate normally according to the requirements of operation instruction of instrument. 5.3.4.2 Immerse electrode into freshly prepared oxygen-free solution at a temperature of (20±5)°C from air; see A.1 in Annex A for preparation of anaerobic water. 5.3.4.3 Instrument indication after 5 min is just the zero error caused by zero bit current. 5.3.5 Verification of response time 5.3.5.1 Control thermostatic water bath temperature to (20±1)°C; prepare saturated dissolved oxygen water according to requirements in A.2 of Annex A. 5.3.5.2 Take electrode out of thermostatic water bath and immerse into oxygen-free water quickly; meanwhile start timing. 5.3.5.3 Stop timing when the instrument displays 90% stable value; the reading of stopwatch is just the response time. 5.3.6 Verification of dissolved oxygen concentration indication error 5.3.6.1 Re-calibrate the instrument. instrument according to Formula (4). )4...(...si  Where, Ti - Instrument indication temperature value, in °C; Ts - Reading of precision thermometer, in °C. Take △T with maximum absolute value as instrument temperature indication error of instrument. 5.3.9 Verification of salinity compensation error 5.3.9.1 Pour 1 L of distilled water into the beaker; place it into thermostatic water bath at a temperature of (15±0.2)°C; stop bubbling 1 h after the start; still for 10 min and measure concentration N0 of dissolved oxygen concentration with zero salt. Standard value of water dissolved oxygen concentration that salt content is n(g/L) is obtained according to Formula (5). )5...(...9055.0-0sn nNN  Where, n - Salt (NaCl) in grams, n may be 10g, 20g and 30g. Note. 0.055 9 refers to the variation of solubility when water temperature is 15°C and salt content is 1 g/L (△Cs). See Annex A of GB/T 11913- 1989. 5.3.9.2 Maintain pure water temperature 15°C; add salt of 10 g and stir uniformly; prepare it to be saturated dissolved oxygen water that salt content is 10 g/L and measure to get N10 (measure for 2 times and take the average value). Use the same method to prepare water into saturated dissolved oxygen water that salt content is 20, 30 g/L and measure to get N20 and N30 respectively. Calculate salinity compensation error according to Formula (6). ߂ܰ ൌ ܰ௡ିܰ௦௡ܰୱ௡ ൈ 100% ... (6) Where, Nn - Concentration of saline dissolved oxygen, which may be N10, N20, N30, in mg/L. Take the △N with the maximum absolute value as salinity compensation error of instrument. 5.4 Verification results handling 5.4.1 In case of poor electrode performance discovered during verification process, it is allowed to replace electrode electrolyte and membrane; re-verification is required after the replacement. 5.4.2 Issue verification qualification certificate for instruments that are verified qualified according to this regulation. For disqualified instruments, issue notice of verification results, Annex F Format of Verification Certificate and Note of Verification Result (Inner Page) F.1 Format of verification certificate (inner pages) Verification Item Technical Requirements Verification Results Appearance Zero error Insulation resistance Dielectric strength Response time Dissolved oxygen concentration indication error Repeatability Temperature indication error Salinity compensation error F.2 Format of notice of verification result (inner pages) Verification Item Technical Requirements Technical Results Conclusion of Single Item Appearance Insulation resistance Dielectric strength Zero error Response time Dissolved oxygen indication error Repeatability Temperature indication error Salinity compensation error Disqualified item. ......

BASIC DATA
Standard ID JJG 291-2018 (JJG291-2018)
Description (Translated English) Dissolved Oxygen Meters
Sector / Industry Metrology & Measurement Industry Standard
Word Count Estimation 19,130
Date of Issue 2018-02-27
Date of Implementation 2018-08-27
Older Standard (superseded by this standard) JJG 291-2008
Drafting Organization Zhejiang Institute of Metrology, Shanghai Institute of Metrology and Testing Technology
Administrative Organization National Environmental Chemometrics Technical Committee
Regulation (derived from) AQSIQ Announcement No. 26 of 2018
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine