HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (29 Sep 2024)

HJ 544-2016 related PDF English

HJ 544-2016 (HJ544-2016) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
HJ 544-2016English279 Add to Cart 3 days Stationary source emission. Determination of sulfuric acid mist. Ion chromatography HJ 544-2016 Valid HJ 544-2016
HJ 544-2009English85 Add to Cart 0-9 seconds. Auto delivery. Stationary source emission - Determination of sulfuric acid mist - Ion chromatography HJ 544-2009 Obsolete HJ 544-2009



HJ 544-2016: PDF in English
HJ 544‐2009  HJ National Environmental Protection Standard of the People’s Republic of China Stationary source emission - Determination of sulfuric acid mist - Ion chromatography (on trial) ISSUED ON. DECEMBER 30, 2009 IMPLEMENTED ON. APRIL 1, 2010 Issued by. Ministry of Environmental Protection Announcement of Ministry of Environmental Protection of the  People’s Republic of China  [2009] No. 74 To implement the “Environmental Protection Law of the People’s Republic of China”, protect the environment and guarantee the human health, “Stationary source emission. Determination of lead. Flame atomic absorption spectrometry” and other 13 standards are approved as the national environmental protection standard and promulgated hereby. The name and serial number of this standard are as follows. HJ 538-2009 Stationary source emission. Determination of lead. Flame atomic absorption spectrometry HJ 539-2009 Ambient air. Determination of lead. Graphite furnace atomic absorption spectrometry HJ 540-2009 Ambient air and waste gas. Determination of arsenic. Silver diethyldithiocarbamate spectrophotometric method HJ 541-2009 Yellow phosphorus production emission. Determination of gaseous arsenic. Silver diethyldithiocarbamate spectrophotometric method HJ 542-2009 Ambient air. Determination of mercury and its compounds. Cold atomic fluorescent spectrophotometry after sulfhydryl cotton preconcentraction HJ 543-2009 Stationary source emission. Determination of mercury. Cold atomic absorption spectrophotometry HJ 544-2009 Stationary source emission. Determination of sulfuric acid mist. Ion chromatography HJ 545-2009 Stationary source emission. Determination of total gaseous phosphorus. Quimociac volumetric analysis HJ 546-2009 Ambient air. Determination of phosphorus pentoxide. Molybdenum blue ascorbiaccid to deoxidize spectrophotometric method HJ 547-2009 Stationary source emission. Determination of chlorine. Iodometric method HJ 548-2009 Stationary source emissions. Determination of hydrogen chloride. Silver nitrate titration method HJ 549-2009 Ambient air and waste gas. Determination of hydrogen chloride. Ion chromatography HJ 550-2009 Water quality. Determination of cobalt. 5-CI-PADAB spectrophotometry HJ 551-2009 Water quality. Determination of chlorin dioxide. Iodometric method Above standards are implemented from April 1, 2010 and published by China Environmental Science Press. Their specific contents are available on the website of the Ministry of Environmental Protection (bz.mep.gov.cn). Hereby it is announced. December 30, 2009 Table of Contents Foreword ... 5  1  Scope of application ... 6  2  Normative references ... 6  3  Method and principle ... 6  4  Interference and elimination ... 7  5  Reagents and materials... 7  6  Instruments and equipment ... 7  7  Samples ... 8  8  Analytical steps ... 10  9  Result calculations ... 11  10  Quality assurance and quality control ... 11  11  Precautions ... 12  Foreword  This standard is formulated to implement the “Environmental Protection Law of the People's Republic of China” and “Law of the People's Republic of China on the Prevention and Control of Atmospheric Pollution”; protect the environment; guarantee human health; and stipulate the monitoring methods of sulfuric acid mist in exhaust gas of stationary pollution source. This standard specifies the ion chromatography for determining the sulfuric acid mist in stationary source emission. This standard is organized and formulated by Department of Science, Technology and Standards of Ministry of Environmental Protection of the People’s Republic of China. Main drafting organization of this standard. Beijing Municipal Environmental Monitoring Center. This standard was approved by Ministry of Environmental Protection on December 30, 2009. The standard shall be implemented on April 1, 2010. The Ministry of Environmental Protection is responsible for the interpretation of this standard. Stationary source emission - Determination of sulfuric acid mist - Ion chromatography (on trial) 1  Scope of application  This standard specifies the ion chromatography for determining the sulfuric acid mist in stationary source emission This standard applies to the determination of sulfuric acid mist in the stationary source emission. For the organized emission, when the filter cartridge is used for preparing 250mL sample, the detection limit of this method is 0.12µg/mL; when sample volume is 400L, the detection limit is 0.08mg/m3, the lower limit of determination is 0.3mg/m3, and the upper limit of determination is 500mg/m3. For the fugitive emission, when the filter membrane is used for preparing 250mL sample, the detection limit of this method is 0.12µg/mL; when sample volume is 3m3, the detection limit is 0.01mg/m3, and the lower limit of determination is 0.04mg/m3. 2  Normative references  The articles contained in the following documents have become part of this standard when they are quoted herein. For the undated documents so quoted, the latest editions shall be applicable to this standard. GB/T 16157 The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source HJ/T 55 Technical guidelines for fugitive emission monitoring of air pollutants HJ/T 373 Technical specifications of quality assurance and quality control for monitoring of stationary pollution source (on trial) 3  Method and principle  In this method, glass fiber filter cartridge or quartz fiber filter cartridge is used for collecting particulate matter sample in organized emission; superfine glass fiber filter membrane or quartz fiber filter membrane is used for collecting particulate matter in fugitive emission. Use water to extract. After removing the metal cation through pre-treatment column, inject the sample into ion chromatograph. Determine the nature in accordance with the retention sampling point inside the exhaust funnel for isokinetic sampling. Appropriately select sampling time according to the concentration of sulfuric acid mist. Meanwhile, determine the necessary temperature, pressure and other parameters. After sampling, carefully take out filter cartridge. Place it into 250mL ground conical flask with stopper. Rinse the sampling mouth and elbow with a little of distilled water. Collect and combine the cleaning lotion into the conical flask. Cover up the flask with stopper. Bring it back to laboratory. Dry the sampling mouth with cotton swab. Dry the elbow with suction bulb for standby. During each sampling, at least three filter cartridges of samples shall be collected; take their average value. 7.1.2 Fugitive emission It shall be implemented in accordance with HJ/T 55 “Technical Guidelines for Fugitive Emission Monitoring of Air Pollutants”. Use the medium-volume particulate matter sampler equipped with filter membrane to collect particulate matter sample at 100L/min for 30min. If the concentration of sulfuric acid mist is too low, the sampling time can be extended appropriately. In order to eliminate the interference of background sulfate from ambient air, reference point shall be set up at upwind direction of fugitive emission; and ambient background sample shall be collected at the same time under the same conditions. Record the sampling conditions. 7.2 Sample preservation The sample in the filter cartridge is put into the ground conical flask with stopper, after collection. The filter membrane sample is folded to put into the clean paper bags for preservation, after collection. 7.3 Sample preparation Select any one of the following sample preparation methods. 7.3.1 Ultrasonic extraction method Cut the samples collected in (7.1) (be sure not to shake off dust particles). Place them into a 250mL ground conical flask with stopper. Add 150mL of deionized water for immersing. Place the conical flask into ultrasonic cleaner. Take out after 30min. Cool down. Filter the leaching solution into a 250mL volumetric flask with medium-speed quantitative filter paper (5.6). Rinse the conical flask and sample residues for (3-4) times, with a little amount of deionized water. Collect and combine the cleaning lotion into the volumetric flask. Add 1.0mol/L or 0.10mol/L sodium hydroxide solution to neutralize the solution to pH 7-9. Dilute to marked line with water. 7.3.2 Heating and leaching method Cut the samples collected in (7.1) (be sure not to shake off dust particles). Place them into a 250mL ground conical flask with stopper. Add 150mL of water to immerse the samples. Place a glass funnel on the flask mouth. Place it into electric furnace or on electric hot 11 Precautions  In-series connect 2 striking absorption flasks that contain absorption liquid, at the back of ... ......

BASIC DATA
Standard ID HJ 544-2016 (HJ544-2016)
Description (Translated English) Stationary source emission. Determination of sulfuric acid mist. Ion chromatography
Sector / Industry Environmental Protection Industry Standard
Classification of Chinese Standard Z25
Word Count Estimation 12,140
Date of Issue 2016-03-29
Date of Implementation 2016-05-01
Older Standard (superseded by this standard) HJ 544-2009
Quoted Standard GB/T 16157; HJ/T 55; HJ/T 373; HJ/T 397
Drafting Organization Beijing Environmental Protection Monitoring Center
Administrative Organization Ministry of Environmental Protection
Regulation (derived from) Ministry of Environmental Protection Announcement No