GB/T 7260.1-2023 Related PDF English (GB 7260.1-2008, GB/T 7260-1987)

GB/T 7260.1-2023 (GB/T7260.1-2023, GBT 7260.1-2023, GBT7260.1-2023) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB/T 7260.1-2023English1194 Add to Cart 8 days Uninterruptible power systems (UPS) -- Part 1: Safety requirements GB/T 7260.1-2023 Valid GBT 7260.1-2023
GB 7260.1-2008English155 Add to Cart 0-9 seconds. Auto delivery. [GB/T 7260.1-2008] Uninterruptible power systems (UPS) -- Part 1-1: General and safety requirements for UPS used in operator access areas GB 7260.1-2008 Valid GB 7260.1-2008
GB/T 7260-1987EnglishRFQ ASK 6 days Uninterruptible power systems GB/T 7260-1987 Obsolete GBT 7260-1987



GB/T 7260:1-2023: Uninterruptible power supply system (UPS) Part 1: Safety requirements ICS 29:200 CCSK85 National Standards of People's Republic of China Replace GB/T 7260:1-2008, GB/T 7260:4-2008 Uninterruptible power supply system (UPS) Part 1: Security Requirements (IEC 62040-1:2022,IDT) Published on 2023-12-28 2024-07-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee Table of contents Preface III Introduction V 1 range 1 2 Normative references 1 3 Terms and Definitions 2 4 Hazard protection 8 4:2 Failures and Abnormal Situations 8 4:3 Short circuit and overload protection 8 4:4 Protection against electric shock10 4:5 Protection against electrical energy hazards 13 4:6 Protection against fire and overheating hazards 13 4:7 Protection against mechanical hazards 14 4:8 Equipment powered by multiple power supplies15 4:9 Protection from environmental stress16 4:10 Protection against sound pressure hazards 16 4:11 Wiring and connections 16 4:101 UPS isolation and disconnection devices 17 4:102 Energy Storage18 4:103 Connection between UPS and communication lines 19 5 Test requirements 20 5:2 Test specifications 23 6 Information and marking requirements31 6:1 Overview 31 6:2 Information for selection 31 6:3 Installation and debugging information 32 6:4 Usage information 33 6:5 Maintenance information 35 Appendix A (Normative) Additional information on protection against electric shock38 Appendix M (informative) Test fixtures for determining accessibility39 Appendix AA (informative) Minimum and maximum cross-sectional areas of copper conductors suitable for connection to external conductor terminals 40 Appendix BB (Normative) Base Load 41 Appendix CC (normative) Ventilation of lead-acid battery compartment 45 Appendix DD (informative) Guidelines for disconnecting batteries during transportation 47 Appendix EE (Informative) Short-time withstand current test procedure (Guidelines and typical values) 49 Appendix FF (informative) Maximum heating effect of transformer test 53 Appendix GG (normative) Installation requirements for rack-mounted equipment 55 Reference 57 Figure 101 Example of opening design to prevent vertical entry 11 Figure 102 Test circuit for reference potential changes caused by load --- single-phase output 25 Figure 103 Test circuit for reference potential changes caused by load---three-phase output 25 Figure 104 Voltage backfeed warning label 34 Figure M:101 Articulated test finger (IP2X) 39 Figure BB:1 Reference resistive load 41 Figure BB:2 Reference inductive-resistive load (series) 42 Figure BB:3 Reference inductive-resistive load (parallel connection) 42 Figure BB:4 Reference capacitive-resistive load (series) 42 Figure BB:5 Reference capacitive-resistive load (parallel connection) 42 Figure BB:6 Reference nonlinear load 43 Figure DD:1 Warning label for products to be transported with battery disconnected47 Figure DD:2 Warning label for products to be shipped with batteries not disconnected47 Figure EE:1 3-wire test circuit of UPS short-term withstand current 49 Figure EE:2 4-wire test circuit of UPS short-term withstand current 50 Figure EE:3 2-wire test circuit for single-phase UPS short-term withstand current 51 Table 1 Glossary 2 Table 101 UPS input port configuration 9 Table 102 Overvoltage Category 11 Table 103 Maximum temperature limit of magnetic components in energy storage power supply mode14 Table 22 Test overview 20 Table 104 Short-time withstand current 27 Table 105 Temperature limits for transformer windings 29 Table A:101 Comparison of operating voltage limits 38 Table AA:1 Conductor cross-sectional area 40 Table FF:1 Test Step 53 Preface This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting: This document is Part 1 of GB/T 7260 "Uninterruptible Power Supply System (UPS)": GB/T 7260 has released the following parts: ---GB/T 7260:2-2009 Uninterruptible power supply system (UPS) Part 2: Electromagnetic compatibility (EMC) requirements; ---GB/T 7260:3-2003 Uninterruptible power supply system (UPS) Part 3: Methods and test requirements for determining performance; ---GB/T 7260:40-2020 Uninterruptible power supply system (UPS) Part 4: Environmental requirements and reporting; ---GB/T 7260:503-2020 Uninterruptible power supply system (UPS) Part 5-3: DC output UPS performance and testing Require: This document replaces GB/T 7260:1-2008 "Uninterruptible power supply equipment - Part 1-1: UPS used in operator reach areas General Provisions and Safety Requirements" and GB/T 7260:4-2008 "Uninterruptible Power Supply Equipment Part 1-2: Restricted Access Area Use General regulations and safety requirements for UPS": Compared with GB/T 7260:1-2008, in addition to structural adjustments and editorial changes, the main technical changes in this document are as follows: a) The content of "Special Applications" has been deleted (see 1:2 of the:2008 version); b) The normative reference documents have been changed (see Chapter 2, Chapter 2 of the:2008 edition); c) Added "Glossary" (see Chapter 3); d) Delete the terms “rated voltage range”, “normal load”, “circuit and circuit characteristics”, “insulation”, “equipment mobility” and “UPS absolute "Enclosure category", "Enclosure", "Accessibility", "Components", "Power distribution system", "Flammability", "Others", "Type test", "Communication network" (see Chapter 3 of the:2008 edition); e) Added the terms "skilled technicians", "trained personnel", "general personnel", "maintenance personnel reach area", "hazardous energy" and "hazardous energy": "Active power", "Apparent power", "Rated data", "Rated value", "Rated load", "Rated peak withstand current", "Rated short-time withstand current" "Flow", "Rated limited short-circuit current", "Low impedance path", "Expected short-circuit current", "Reference test load", "Reference non-linear load", "Short "circuit protection device", "ground fault" and "movable uninterruptible power supply system" (see 3:102~3:105, 3:107, 3:111~3:115, 3:118~3:122, 3:125, 3:126, 3:130, 3:131, 3:132); f) The term "hazardous voltage" has been changed (see 3:106, 3:5:1 of the:2008 edition): Compared with GB/T 7260:4-2008, in addition to structural adjustments and editorial changes, the main technical changes in this document are as follows: a) The content of "special applications" has been deleted (see 1:2 of the:2008 version); b) The normative reference documents have been changed (see Chapter 2, Chapter 2 of the:2008 edition); c) Added "Glossary" (see Chapter 3); d) The terms "continuity of load power", "power failure", "rated voltage range", "base load" and "equipment mobility" are deleted "Insulation categories of UPS" "Connection to power supply" "Enclosure" "Accessibility" "Circuit and circuit characteristics" "Insulation" "Clearances and Creepage distance", "Components", "Power distribution system", "Flammability", "Others", "Type test", "Communication network" (see No: 3 of the:2008 edition chapter); e) Added the terms "skilled technicians", "trained personnel", "general personnel", "maintenance personnel reach area", "hazardous energy" and "software": Line" "Rated data" "Rated value" "Rated load" "Rated peak withstand current" "Rated short-time withstand current" "Rated short circuit limit Current" "Low impedance path" "Expected short circuit current" "Reference test load" "Reference nonlinear load" "Backfeed protection" "Short circuit Protection device", "ground fault" and "movable uninterruptible power supply system" (see 3:102~3:105, 3:107, 3:109, 3:113~3:115, 3:118~3:122, 3:125, 3:126, 3:128, 3:130, 3:131, 3:132); f) The content of "hazardous voltage" has been changed (see 3:106, 3:8:1 of the:2008 edition): This document is equivalent to IEC 62040-1:2022 "Uninterruptible Power Supply System (UPS) Part 1: Safety Requirements": This document has made the following minimal editorial changes: ---For ease of use, "Note" has been added to the following terms: ● The requirements for battery flame retardancy grade are explained (see 4:6:2:2); ● Give the source of the definition of conductor in Table AA:1 (see Appendix AA); ● Provide information about the reference nonlinear load in the relevant standard (IEC 62040-3:2021) (see Appendix BB:5:3): ---Give the clause number "4:4:7:4" in the electrical clearance and creepage distance test requirements column in Table 22 to correspond to the electrical clearance requirements Terms (see 5:1:7:101); ---Correct the clause numbers "4:3:103:2" and "4:3:101:2" quoted in the general procedure of "Short-time withstand current test (type test)" is "4:3:103" (see 5:2:3:103:1): Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents: This document is proposed by the China Electrical Equipment Industry Association: This document is under the jurisdiction of the National Technical Committee for Standardization of Power Electronic Systems and Equipment (SAC/TC60): This document was drafted by: Vertiv Technology Co:, Ltd:, Guangdong Zhicheng Champion Group Co:, Ltd:, Xi'an Power Electronics Technology Research Institute Co:, Ltd: Company, Kehua Data Co:, Ltd:, Schneider Electric Information Technology (China) Co:, Ltd:, Shenzhen Costar Technology Co:, Ltd:, China Guangdong Nuclear Power Engineering Co:, Ltd:, Xiamen Avida Electronics Co:, Ltd:, Huazhong University of Science and Technology, Huawei Digital Energy Technology Co:, Ltd:, Fujian Provincial Quality Inspection Institute, North China University of Technology, Changsha Otto Automation Technology Co:, Ltd:, AVIC Tech (Xiamen) Power Technology Co:, Ltd: Company, Jiangsu Hongwei Technology Co:, Ltd:, Hangzhou Borui Electronic Technology Co:, Ltd:, Zhangzhou Kehua Technology Co:, Ltd:, Wenzhou University Science, China Academy of Information and Communications Technology, Dongguan Electronic Information Industry Association, Reynolds (Changzhou) Electronics Co:, Ltd:, Shenzhen Jingquanhua Technology Co:, Ltd: CO:, LTD: The main drafters of this document: Peng Huaidong, Zhao Zhen, Li Minying, Wei Hongqi, Zhan Biying, Ding Wei, Liu Liyang, Fu Mingxing, Ning Yong, Chen Yifeng, Zhang Yu, Zhang Xiaofei, Zhu Nairong, Zhou Jinghua, Jiang Ting, Su Peiqin, Rongrui, Li Jiming, Zeng Yizhang, Dai Yuxing, Qi Shuguang, Zhang Wei, Song Bo, Zhu Yong: The previous versions of this document and the documents it replaces are as follows: ---First published in:2008 as GB/T 7260:1-2008 "Uninterruptible power supply equipment - Part 1-1: Use in operator reach areas" General regulations and safety requirements for UPS"; ---This is the first revision, incorporating GB/T 7260:4-2008 "Uninterruptible Power Supply Equipment Part 1-2: Restricted Access Areas" General regulations and safety requirements for the use of UPS: introduction GB/T 7260 provides a series of universal standards for uninterruptible power systems (UPS): It is planned to consist of the following parts: ---GB/T 7260:1 Uninterruptible power supply system (UPS) Part 1: Safety requirements: The purpose is to ensure that the contact is uninterrupted The safety of general personnel and skilled technicians of the source system, reduction during use and operation and special instructions for repair and maintenance Risks of fire, electrical shock, thermal, energy and mechanical hazards during: ---GB/T 7260:2 Uninterruptible power supply system (UPS) Part 2: Electromagnetic compatibility (EMC) requirements: The purpose is to ensure The uninterruptible power supply system meets the necessary basic EMC requirements to avoid the uninterruptible power supply system from interfering with other equipment and to prevent uninterruptible power supply systems from interfering with other equipment: The power outage system is affected by external devices: ---GB/T 7260:3 Uninterruptible power supply system (UPS) Part 3: Methods and test requirements for determining performance: The purpose is Specifies the performance and test requirements for complete uninterruptible power supply systems and individual uninterruptible power supply system functional units: ---GB/T 7260:40 Uninterruptible power supply system (UPS) Part 4: Environmental requirements and reports: The purpose is to provide regulatory It provides a reference for manufacturers, purchasers, certification bodies and users to reduce the impact of uninterruptible power supply systems on their service life: environmental impact: ---GB/T 7260:501 Uninterruptible power supply system (UPS) Part 5-1: Safety requirements for DC output UPS: The purpose is To ensure the safety of general personnel and skilled technicians who come into contact with the DC uninterruptible power supply system, and to reduce the risk of damage during use and operation: and risks of fire, electric shock, thermal, energy and mechanical hazards during repair and maintenance as specified: ---GB/T 7260:503 Uninterruptible power supply system (UPS) Part 5-3: DC output UPS performance and test requirements: The purpose is to standardize the performance and testing of a complete DC uninterruptible power supply system (rather than a single DC uninterruptible power supply functional unit) Require: This document is harmonized with the applicable parts of IEC 62477-1:2012: The provisions in IEC 62477-1:2012 are only specified in this document References apply to this document: In this document, when quoting the clauses in IEC 62477-1:2012, the corresponding identification is given, for example, "Except for the following "Except, Chapter 4 of IEC 62477-1:2012 applies"; Clauses added in addition to the numbering of clauses, figures and tables in IEC 62477-1:2012 Paragraphs, figures and tables shall be identified in the format of "×: out to show the difference from the appendix numbers in IEC 62477-1:2012: Uninterruptible power supply system (UPS) Part 1: Security Requirements 1 Scope This document applies to low-voltage power distribution systems intended for installation in areas accessible to general personnel or restricted access areas (if applicable): Mobile, non-movable, fixed installation or built-in uninterruptible power supply system (UPS), which contains energy storage device and outputs fixed frequency alternating current voltage, and its port voltage does not exceed AC 1000V or DC 1500V: This document is applicable to installation according to the method specified by the manufacturer: Installation, operation and maintenance of plug-in or permanently connected UPS, whether composed of interconnected units or independent units: Note 1: IEC 62040-3 describes typical UPS configurations, including voltage and/or frequency converters and other topologies: Note 2: UPS is usually connected to its energy storage device through a DC link: This document uses chemical batteries as an example of an energy storage device: Alternative devices exist , therefore, the "battery" in this document is the "energy storage device": This document specifies the requirements to ensure the safety of general personnel and skilled technical personnel (if specified) who come into contact with the UPS: The purpose is to Reduce the risk of fire, electrical shock, thermal, energy and mechanical hazards during use and operation and during specially stated service and maintenance: This document is consistent with the applicable parts of the multidisciplinary safety publication IEC 62477-1:2012 for power electronic converter systems: adjustment, and includes additional requirements related to UPS: This document does not cover: ● UPS with DC output; ● Systems used on mobile platforms (including but not limited to aircraft, ships and motor vehicles); ● External AC or DC input and output distribution boards covered by its product-specific standards; ● Independent static switching system (STS) covered by IEC 62310-1; ● Systems where the output voltage comes directly from the rotating electrical machine; ● Parts of telecommunications equipment other than UPS; ● Functional safety aspects covered by IEC 61508 (all parts): Note 3: Although this document does not cover the above applications, it is generally used as a guide for such applications: Note 4: Special purpose UPS (such as medical UPS) are usually subject to additional requirements in other documents: 2 Normative reference documents The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document: Except for the following, Chapter 2 of IEC 62477-1:2012 applies: Add the following normative reference documents: GB/T 7260:2-2009 Uninterruptible power supply equipment (UPS) Part 2: Electromagnetic compatibility (EMC) requirements (IEC 62040-2: 2005,IDT) GB/T 14536:1-2022 Electric automatic controllers Part 1: General requirements (IEC 60730-1:2013, IDT) IEC 60364-4-42 Low-voltage electrical installations Part 4-42: Safety protection Thermal effect protection (Low-voltageelectricalin- Note: GB/T 16895:2-2017 Low-voltage electrical installations Part 4-42: Safety protection thermal effect protection (IEC 60364-4-42:2010, IDT) IEC 60384-14 Fixed capacitors for electronic equipment Part 14: Specification for fixed capacitors used to suppress electromagnetic interference from power supplies ......


GB/T 7260.1-2008 (GB 7260.1-2008) GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.200 K 85 GB/T 7260.1-2008 Uninterruptible power systems (UPS) – Part 1-1. General and safety requirements for UPS used in operator access areas (IEC 62040-1-1.2002, MOD) ISSUED ON. MAY 20, 2008 IMPLEMENTED ON. APRIL 01, 2009 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 1 Scope and specific applications ... 5 2 Normative references ... 6 3 Definitions ... 7 4 General conditions for tests ... 12 5 Fundamental design requirements ... 19 6 Wiring, connections and supply ... 27 7 Physical requirements ... 28 8 Electrical requirements and simulated abnormal conditions ... 33 9 Connection to telecommunication networks ... 35 Annex A (normative) Test for resistance to heat and fire ... 36 Annex B (normative) Motor tests under abnormal conditions ... 36 Annex C (normative) Transformers ... 36 Annex D (normative) Measuring instruments for touch-current tests ... 36 Annex E (normative) Temperature rise of a winding ... 36 Annex F (normative) Measurements of clearances and creepage distances . 37 Annex G (normative) Alternative method for determining minimum clearances. ... 37 Annex J (informative) Table of electrochemical potentials ... 37 Annex K (normative) Thermal controls ... 37 Annex H (informative) Guidance on protection against ingress of water and foreign objects ... 38 Annex L (normative) Backfeed protection test ... 40 Annex M (normative) Examples of reference load conditions ... 42 Annex N (normative) Ventilation of battery compartments ... 47 Annex X (informative) Guidance for disconnection of batteries during shipment ... 51 Foreword All technical contents of this Part are mandatory. GB 7260 “Uninterruptible power systems (UPS)” consists of the following parts. - Part 1-1. General and safety requirements for UPS used in operator access areas; - Part 1-2. General and safety requirements for UPS used in restricted access locations; - Part 2. Electromagnetic compatibility (EMC) requirements; - Part 3. Method of specifying the performance and test requirements. This Part of is Part 1-1 of GB 7260. This Part modifies IEC 62040-1-1.2002 “Uninterruptible power systems (UPS) - Part 1-1. General and safety requirements for UPS used in operator access areas”. Compare this Part with IEC 62040-1-1.2002, there are the following technical differences. 4.5.15 of this Part is revised to “Unless otherwise required by the user, the documents, human-machine interfaces and markings provided to the end user shall use the standard Chinese.” In this Part, annexes A, B, C, D, E, F, G, K, L, M and N are normative, annexes H, J and X are informative. This Part was proposed by China Electrical Equipment Industry Association. This Part shall be under the jurisdiction of National Technical Committee on Power Electronics of Standardization Administration of China (SAC/TC 60). Responsible drafting organizations of this Part. Emerson Network Power Co., Ltd., Shanghai Forward Technology Co., Ltd. Participating drafting organizations of this Part. Delta Electronic Communications Co., Ltd., Qingdao Rectifier Manufacturing Co., Ltd., Xi’an Power Electronics Research Institute, Qingdao Economic and Technological Development Zone Chuangtong Technology Development Co., Ltd. Main drafters of this Part. Qiu Jianqing, Wang Aosheng, Jiang Weishi, Zhang Xifan, Wei Hongqi, Sui Xueli, Wu Shengzhang, Shao Mingle, Zhou Guanyun, Wang Ying, Wang Weihui. Uninterruptible power systems (UPS) – Part 1-1. General and safety requirements for UPS used in operator access areas 1 Scope and specific applications 1.1 Scope This Part of GB 7260 applies to electronic uninterruptible power systems with an electrical energy storage device in the d.c. link. This Part refers to the relevant contents of GB 4943-2001 and IEC 60950-1.2001. The primary function of the uninterruptible power systems (UPS) covered by this Part is to ensure continuity of an alternating power source. The UPS may also serve to improve the quality of the power source by keeping it within specified characteristics. Notes on regional differences in relevant clauses of GB 4943-2001 and IEC 60950-1. 2001 also apply. This Part is applicable to UPS which are movable, stationary, fixed or for building-in, for use on low-voltage distribution systems and intended to be installed in any operator accessible area. This Part specifies requirements to ensure safety for the operator and layman who may come into contact with the equipment and, where specifically stated, for the service person. This Part is intended to ensure the safety of installed UPS, both as a single UPS unit or as a system of interconnected UPS units, subject to installing, operating and maintaining the UPS in the manner prescribed by the manufacturer. This Part does not cover d.c. supplied electronic ballasts (IEC 60924 and IEC 60925), UPS intended to be installed in separated electrical locations and UPS based on rotating machines. The relevant general and safety requirements for UPS installed in restricted access locations are given in GB 7260.4; electromagnetic compatibility (EMC) requirements and definitions are given in GB 7260.2. 1.2 Specific applications Even if this Part does not cover all types of UPS, it may be taken as a guide for such equipment. Requirements additional to those specified in this Part may be necessary for specific applications, for example. ......

BASIC DATA
Standard ID GB/T 7260.1-2023 (GB/T7260.1-2023)
Description (Translated English) Uninterruptible power systems (UPS) -- Part 1: Safety requirements
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K85
Classification of International Standard 29.200
Word Count Estimation 66,668
Date of Issue 2023-12-28
Date of Implementation 2024-07-01
Older Standard (superseded by this standard) GB/T 7260.1-2008; GB/T 7260.4-2008
Drafting Organization Vertiv Technology Co., Ltd., Guangdong Zhicheng Champion Group Co., Ltd., Xi'an Power Electronics Technology Research Institute Co., Ltd., Kehua Data Co., Ltd., Schneider Electric Information Technology (China) Co., Ltd., Shenzhen Costar Technology Co., Ltd., China Guangdong Nuclear Power Engineering Co., Ltd., Xiamen Avida Electronics Co., Ltd., Huazhong University of Science and Technology, Huawei Digital Energy Technology Co., Ltd., Fujian Product Quality Inspection Institute, North China University of Technology, Changsha Otto Automation Technology Co., Ltd., AVIC Tek (Xiamen) Electric Power Technology Co., Ltd., Jiangsu Hongwei Technology Co., Ltd., Hangzhou Borui Electronic Technology Co., Ltd., Zhangzhou Kehua Technology Co., Ltd., Wenzhou University, China Academy of Information and Communications Technology, Dongguan Electronic Information Industry Association, Reynolds (Changzhou) ) Electronics Co., Ltd.
Administrative Organization National Technical Committee on Standardization of Power Electronic Systems and Equipment (SAC/TC 60)
Proposing organization China Electrical Equipment Industry Association
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration

BASIC DATA
Standard ID GB 7260.1-2008 (GB7260.1-2008)
Description (Translated English) [GB/T 7260.1-2008] Uninterruptible power systems(UPS). Part 1-1: General and safety requirements for UPS used in operator access areas
Sector / Industry National Standard
Classification of Chinese Standard K85
Classification of International Standard 29.200
Word Count Estimation 33,325
Date of Issue 2008-05-20
Date of Implementation 2009-04-01
Adopted Standard IEC 62040-1-1-2002, MOD
Drafting Organization Emerson Network Power Co., Ltd.
Administrative Organization National Standardization Technical Committee of Power Electronics
Regulation (derived from) Announcement of Newly Approved National Standards No. 8, 2008 (No. 121 overall)
Proposing organization China Electrical Equipment Industry Association
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Chinese standard relates to DC link energy storage device having an electronic uninterruptible power supplies. This standard refers to GB 4943-2001 and IEC 60950-1: 2001 related content. This standard includes an uninterruptible power supply (UPS) primary function is to ensure the continuity of AC power supply output. UPS also allows power to maintain the specified characteristics, thereby improving power quality. GB 4943-2001 and IEC 60950-1: 2001 relevant chapters on regional differences comments also apply. This standard applies to pre- installed in the operator access area, low-voltage distribution systems for mobile, stationary, fixed or embedded -mounted UPS.

BASIC DATA
Standard ID GB/T 7260-1987 (GB/T7260-1987)
Description (Translated English) Uninterruptible power systems
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K85
Word Count Estimation 28,239
Date of Issue 1987/2/13
Date of Implementation 1987/11/1