HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (1 Dec 2024)

GB/T 42696-2023 Related PDF English

GB/T 42696-2023 (GB/T42696-2023, GBT 42696-2023, GBT42696-2023) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB/T 42696-2023English170 Add to Cart 0-9 seconds. Auto delivery. Textiles -- Determination of phosphate compounds GB/T 42696-2023 Valid GBT 42696-2023
Buy with any currencies (Euro, JPY, KRW...): GB/T 42696-2023    Preview this PDF: GB/T 42696-2023



GB/T 42696-2023 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 59.080.01 CCS W 04 Textiles - Determination of phosphate compounds ISSUED ON: MAY 23, 2023 IMPLEMENTED ON: DECEMBER 1, 2023 Issued by: State Administration for Market Regulation; Standardization Administration of the PRC. Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Principle ... 4 5 Reagents and materials ... 4 6 Apparatus ... 5 7 Analytical procedure ... 6 8 Calculation and presentation of results ... 9 9 Limit of quantification and precision ... 9 10 Test report ... 10 Appendix A (Informative) Gas chromatogram of phosphate compound standard substances ... 11 Appendix B (Informative) Gas chromatography-mass spectrometry selected ion chromatogram of phosphate compound standard substances ... 12 Textiles - Determination of phosphate compounds Warning - Personnel using this document shall have practical experience in regular laboratory work. This document does not purport to address all possible safety problems. Users are responsible for taking appropriate safety and health measures AND ensuring the conditions specified in relevant national regulations. 1 Scope This document describes the gas chromatography and gas chromatography-mass spectrometry methods for the determination of the content of 8 phosphate compounds in textiles. This document applies to all types of textiles. 2 Normative references There are no normative references in this document. 3 Terms and definitions There are no terms or definitions to be defined in this document. 4 Principle Use ethyl acetate to ultrasonically extract the specimen. After the extract is filtered through a filter membrane, use a gas chromatograph equipped with a flame photometric detector (P type) to measure; or use a gas chromatograph-mass spectrometer to measure. Use the external standard method for quantification. 5 Reagents and materials Unless otherwise specified, all reagents used are chromatographically pure. 5.1 Tributyl phosphate (TBP): CAS number 126-73-8 (purity≥98.5%). 5.2 Triphenyl phosphate (TPP): CAS number 115-86-6 (purity≥99.7%). 5.3 Tri-o-cresyl phosphate (ToCP): CAS number 78-30-8 (purity≥96%). 5.4 Tri-m-cresyl phosphate (TmCP): CAS number 563-04-2 (purity≥95%). 5.5 Tri-p-cresyl phosphate (TpCP): CAS number 78-32-0 (purity≥98%). 5.6 Trioctyl phosphate (TOP): CAS number 78-42-2 (purity≥98%). 5.7 Diphenyl octyl phosphate (DPOP): CAS number 1241-94-7 (purity≥90%). 5.8 Cresyl diphenyl phosphate (CDP): CAS number 26444-49-5 (purity≥93%). 5.9 Ethyl acetate. 5.10 Standard stock solution: Use ethyl acetate (5.9) to prepare the standard substances listed in 5.1~5.8 into a single-component standard stock solution with a mass concentration of approximately 1000 mg/L, respectively. Note: The standard stock solution is stored in the dark at 0 °C~4 °C and is valid for 6 months. 5.11 Standard working solution: Pipette 8 appropriate amounts of phosphate compound standard stock solutions (5.10) respectively; place them in the same volumetric flask. Use ethyl acetate (5.9) to prepare a mixed standard working solution with a mass concentration of approximately 100 mg/L. Then according to work needs, use ethyl acetate (5.9) to prepare a standard working solution of appropriate concentration. Note: The standard working solution is stored in the dark at 0 °C~4 °C and is valid for 3 months. 6 Apparatus 6.1 Gas chromatograph (GC-FPD): It is equipped with flame photometric detector (P type). 6.2 Gas chromatograph-mass spectrometer (GC-MS): It is equipped with electron impact ionization source (EI). 6.3 Ultrasonic generator: Working frequency is (40±5)kHz. 6.4 Analytical balance: Graduation values are 0.1 mg and 0.01 g, respectively. 6.5 Vortex mixer. 6.6 Extraction tube: It has an airtight stopper; is about 50 mL; made of hard glass. 6.7 Disposable syringe. 6.8 Organic-phase needle filter head: Pore size is 0.45 μm. retention times of the specimen solution and the standard working solution, perform qualitative analysis. Use the chromatographic peak area of the standard substance as the ordinate; use the concentration of the standard working solution as the abscissa; draw a standard working curve. Use the external standard method to perform quantitative analysis. Note: When the above analysis conditions are used, the GC-FPD (P type) analysis chromatogram of 8 phosphate compound standard substances are shown in Appendix A. Cresyl diphenyl phosphate (CDP Ⅰ) and cresyl diphenyl phosphate (CDP Ⅱ) are isomers of each other; the CDP result is the sum of the isomers. 7.4 Gas chromatography-mass spectrometry analysis method 7.4.1 Gas chromatography-mass spectrometry analysis conditions Since the test results are related to the instrument and conditions used, it is impossible to give universal parameters for instrument analysis. The following parameters have been proven to be suitable for the test. a) Chromatographic column: HP-5MS, 30 m×0.25 mm×0.25 μm; or equivalent. b) Column temperature programming: c) Inlet temperature: 250 °C. d) Mass spectrometer interface temperature is 250 °C. e) Ion source temperature: 230 °C. f) Quadrupole temperature is 150 °C. g) Ionization method: EI. h) Ionization energy: 70 eV. i) Detection method: Selected ion monitoring (SIM) mode; the monitoring ions are shown in Table 1. j) Solvent delay: 8 min. k) Carrier gas: Helium; purity≥99.999%; 1 mL/min. l) Injection method: Splitless injection; open the valve after 2 min. m) Injection volume: 1 μL. 8 Calculation and presentation of results According to formula (1), calculate the content of each phosphate compound in the specimen. The test results are expressed as the content of each phosphate compound, respectively. Calculation results are expressed to one decimal place. Where: Xi - The content of phosphate compound i in the specimen, in milligrams per kilogram (mg/kg); Ci - The mass concentration of the phosphate compound i to be measured in the sample solution obtained from the standard working curve, in milligrams per liter (mg/L); Ci0 - The mass concentration of phosphate compound i in the blank specimen solution in the sample solution obtained from the standard working curve, in milligrams per liter (mg/L); V - The final constant volume of sample solution, in milliliters (mL); m - Specimen mass, in grams (g); f - Dilution factor. 9 Limit of quantification and precision 9.1 Limit of quantification The limits of quantification of the 8 phosphate compounds in textiles using the gas chromatography method are all 2.0 mg/kg. The limits of quantification of the 8 phosphate compounds in textiles using gas chromatography-mass spectrometry are all 1.0 mg/kg. 9.2 Precision In the same laboratory, by the same operator, using the same equipment, according to the same test method, the absolute difference between the results of two tests obtained independently of each other on the same subject within a short period of time IS not greater than 15% of the arithmetic mean of the two measured values; provided that in the case of greater than 15%, it does not exceed 5%. ......

BASIC DATA
Standard ID GB/T 42696-2023 (GB/T42696-2023)
Description (Translated English) Textiles -- Determination of phosphate compounds
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard W04
Classification of International Standard 59.080.01
Word Count Estimation 10,121
Date of Issue 2023-05-23
Date of Implementation 2023-12-01
Drafting Organization Zhejiang Provincial Institute of Inspection and Quarantine Science and Technology, China Textile Standard (Shenzhen) Testing Co., Ltd., Fujian Jinjiang Huayu Weaving Co., Ltd., Kezhihua Inspection and Testing (Fujian) Co., Ltd., Zhejiang Longqi Printing and Dyeing Co., Ltd., Zhejiang Compida Textile Technology Co., Ltd., China Textile Standard Inspection and Certification Co., Ltd., Fuzhou Yongshengfa Knitting Co., Ltd., Fujian Fiber Inspection Center, Quanzhou Bogeng Biotechnology Co., Ltd., Zhejiang University of Science and Technology, Dongguan Weiside Technology Development Co., Ltd., Zhejiang Card carolina textile co., ltd.
Administrative Organization National Textile Standardization Technical Committee (SAC/TC 209)
Proposing organization China Textile Industry Federation
Issuing agency(ies) State Administration for Market Regulation, National Standardization Management Committee