GB/T 40191-2021English95 Add to Cart 0-9 seconds. Auto delivery. Determination of restricted preservatives in toothpaste - High performance liquid chromatography method GB/T 40191-2021 Valid GBT 40191-2021
Buy with any currencies (Euro, JPY, KRW...): GB/T 40191-2021    Preview this PDF: GB/T 40191-2021



GB/T 40191-2021: PDF in English (GBT 40191-2021)
GB/T 40191-2021 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.040.40 Y 43 Determination of restricted preservatives in toothpaste - High performance liquid chromatography method ISSUED ON: MAY 21, 2021 IMPLEMENTED ON: DECEMBER 01, 2021 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Principle ... 4  4 Reagents and standard materials ... 4  5 Instruments ... 5  6 Specimen preparation ... 5  7 Determination by high performance liquid chromatography ... 6  8 Result calculation ... 7  9 Precision ... 7  Annex A (informative) Liquid chromatogram of mixed benzoic acid and sorbic acid standard sample ... 8  Determination of restricted preservatives in toothpaste - High performance liquid chromatography method 1 Scope This Standard specifies high performance liquid chromatography (HPLC) method to determine the content of restricted preservatives - sorbic acid and benzoic acid - in toothpaste. This Standard is applicable to the determination of the content of restricted preservatives - sorbic acid and benzoic acid - in toothpaste. The method detection limit of this Standard is 0.5mg/kg. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682-2008, Water for analytical laboratory use - Specification and test methods 3 Principle Use pure water to extract the sample. The supernatant is filtered through a 0.45μm filter membrane. Use high performance liquid chromatography- ultraviolet detection method to determine. Use retention time to characterize. Use external standard peak area method to quantify. 4 Reagents and standard materials Unless otherwise specified, all reagents used are analytically-pure AND water is grade one water specified in GB/T 6682-2008. 4.1 Methanol: chromatographically pure. value to 7. After shaking for 15min, add pure water to set volume to 25mL. Shake well. Let it still. Transfer the supernatant to the centrifuge tube. Centrifuge at 4000r/min for 10min. Take the supernatant and pass it through the 0.45μm microporous membrane. Inject a sample to test. 7 Determination by high performance liquid chromatography 7.1 Reference conditions of liquid chromatography The reference conditions of liquid chromatography are as follows: a) Chromatographic column: C18 stainless steel column (250mm×4.6mm×5μm). b) Detection wavelength: 230nm. c) Mobile phase: methanol/ammonium acetate aqueous solution (0.02mol/L) (5:95, volume ratio). d) Flow rate: 1.0mL/min. e) Column temperature: 30°C. f) Injection volume: 10μL. 7.2 Preparation of standard working solution Use mobile phase solution to gradually dilute the 100mg/L mixed standard solution (4.7). Prepare into 50mg/L, 20mg/L, 10mg/L, 5mg/L standard working solutions. Filter by 0.45μm filter membrane for future use. Under the set chromatographic conditions, respectively take 10μL for analysis. Take the mass concentration of the standard series of solutions as the abscissa (mg/L), the peak area of the reference substance as the ordinate to draw the calibration curve (linear correlation coefficient R ≥0.9990). Refer to Figure A.1 in Annex A for the liquid chromatogram of the mixed benzoic acid and sorbic acid standard sample. 7.3 Determination steps After the sample is processed according to the steps in Chapter 6, perform on- board testing according to the instrument conditions of 7.1. The response values of benzoic acid and sorbic acid in the test sample solution shall be within the linear range of the standard curve. If it exceeds the linear range, it shall be diluted before injection for determination. ......

BASIC DATA
Standard ID GB/T 40191-2021 (GB/T40191-2021)
Description (Translated English) Determination of restricted preservatives in toothpaste - High performance liquid chromatography method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y43
Classification of International Standard 71.040.40
Word Count Estimation 6,610
Date of Issue 2021-05-21
Date of Implementation 2021-12-01
Drafting Organization Jiangsu Product Quality Supervision and Inspection Institute, Jiangsu Physical and Chemical Testing Center
Administrative Organization National Oral Care Products Standardization Technical Committee (SAC/TC 492)
Regulation (derived from) National Standard Announcement No. 7 of 2021
Proposing organization China National Light Industry Council
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration