HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (14 Sep 2024)

GB/T 20882.2-2021 related PDF English

GB/T 20882.2-2021 (GB/T20882.2-2021, GBT 20882.2-2021, GBT20882.2-2021) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB/T 20882.2-2021English230 Add to Cart 0-9 seconds. Auto delivery. Quality requirements for starch sugar -- Part 2: Glucose syrup and glucose syrup powder GB/T 20882.2-2021 Valid GBT 20882.2-2021
Buy with any currencies (Euro, JPY, KRW...): GB/T 20882.2-2021    Preview this PDF: GB/T 20882.2-2021



GB/T 20882.2-2021: PDF in English (GBT 20882.2-2021)
GB/T 20882.2-2021 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 67.180.20 CCS X 31 Replacing GB/T 20885-2007 Quality requirements for starch sugar - Part 2: Glucose syrup and glucose syrup powder ISSUED ON: DECEMBER 31, 2021 IMPLEMENTED ON: JULY 01, 2022 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  Introduction ... 5  1 Scope ... 6  2 Normative references ... 6  3 Terms and definitions... 6  4 Product classification ... 7  5 Requirements ... 7  6 Test methods ... 8  7 Inspection rules ... 14  8 Marking, packaging, transportation and storage ... 16  Appendix A (Informative) Determination of sugar boiling temperature ... 18  Quality requirements for starch sugar - Part 2: Glucose syrup and glucose syrup powder 1 Scope This document specifies the quality requirements for glucose syrup and glucose syrup powder, including terms and definitions, product classification, requirements, test methods, inspection rules, marking, packaging, transportation and storage. This document applies to the production, inspection and sales of glucose syrup and glucose syrup powder. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document. GB/T 191, Packaging - Pictorial marking for handling of goods GB/T 601, Chemical reagent - Preparations of reference titration solutions GB/T 602, Chemical reagent - Preparations of standard solutions for impurity GB/T 603, Chemical reagent - Preparations of reagent solutions for use in test methods GB 5009.3-2016, National Food Safety Standard - Determination of Moisture Content in Foods GB/T 6682, Water for analytical laboratory use - Specification and test methods 3 Terms and definitions The following terms and definitions are applicable to this document. 3.1 glucose syrup Weigh 1.5 g (accurate to 0.000 1 g) of standard or high-purity (99.5% pure) anhydrous dextrose which has been dried to constant weight at 105 °C ± 2 °C; dissolve in water, and dilute to 250 mL; shake well and set aside. This solution shall be prepared on the day of use. 6.3.1.3 Fehling's reagent 6.3.1.3.1 Fehling’s solution I: Weigh 34.7 g of copper sulfate pentahydrate (CuSO4·5H2O); add water to dissolve and dilute to 500 mL; shake well. 6.3.1.3.2 Fehling's solution II: Weigh 173.0 g of potassium sodium tartrate tetrahydrate (C4H4KNaO6·4H2O) and 50.0 g of sodium hydroxide (NaOH); add water to dissolve and dilute to 500 mL; shake well. 6.3.1.3.3 Mixed Fehling's solution: Pour 100 mL Fehling's solution I and 100 mL Fehling's solution II into a dry reagent bottle; mix them evenly. Note: This solution is prepared for immediate use. 6.3.1.3.4 Calibration: During pre-titration, pipette 25 mL of mixed Fehling’s solution into a conical flask; add 10 mL of water; add three glass beads; use a 25 mL burette to add 18 mL of glucose standard solution in advance; shake well; place it on an electric furnace that is covered with asbestos mesh to heat; control the liquid in the bottle to boil within 120 s ± 15 s and keep it slightly boiled for 2 min; add two drops of methylene blue indicator solution; add standard glucose solution drop by drop from the burette (one drop for about 2 s is appropriate) until the blue color just fades as the end point. The entire titration operation shall be completed within 1 min. In the formal titration, add standard glucose solution which is 0.5 mL less than the pre-titration in advance, where the operation is the same as the pre-titration. Add the standard glucose solution drop by drop until the blue color just disappears. The entire titration operation shall be completed within 1 min. At the same time, perform a parallel experiment, and record the total volume of consumed glucose solution (whichever is the arithmetic mean). The mass of glucose equivalent to 25 mL of Fehling’s mixed solution is calculated according to Formula (1): Where: RP – the mass of glucose equivalent to 25 mL of Fehling’s mixed solution, in grams (g); m1 – the mass of the weighed standard anhydrous glucose, in grams (g); V1 – total volume of the consumed standard glucose solution, in milliliters (mL); 250 – total volume of the prepared standard glucose solution, in milliliters (mL). The absolute difference between two independent determination results which are obtained under repeatability conditions shall not exceed 1% of its arithmetic mean. 6.5 Moisture Measure according to Method I of GB 5009.3-2016, "Direct drying method", in which the drying temperature is set to 105 °C ± 2 °C. 6.6 pH 6.6.1 Instruments and apparatuses Acidity meter: The accuracy is 0.01 pH; it is equipped with glass electrode and calomel electrode (or composite electrode). 6.6.2 Analysis steps 6.6.2.1 Determination method Adjust and calibrate the pH meter according to the instrument instruction manual. Weigh an appropriate amount of sample; use freshly boiled and cooled (carbon dioxide removed) water whose pH is 5.0 ~ 7.0 to prepare a glucose syrup with a dry matter of 30%. Then, use water to rinse the electrode probe; use a filter paper to dry it gently; insert the electrode into the sample solution to be tested; turn on the electromagnetic stirrer; adjust the temperature regulator so that the indicated temperature of the instrument is the same as the solution temperature; read after it is stable. 6.6.2.2 Result expression Express the calculation result to one decimal place. 6.6.3 Precision The absolute difference between two independent determination results which are obtained under repeatability conditions shall not exceed 3% of its arithmetic mean. 6.7 Light transmittance 6.7.1 Instruments and apparatuses Spectrophotometry. 6.7.2 Analysis steps 6.7.2.1 Determination method According to the instrument manual, adjust the zero point and light transmittance of the instrument at a wavelength of 440 nm. Weigh an appropriate amount of sample; use carbon dioxide removed water whose pH is 5.0 ~ 7.0 to prepare a glucose syrup with a dry matter of 30%. Then, inject the to-be-tested solution into a 1 cm cuvette; use a spectrophotometer, at a wavelength of 440 nm, to measure the light transmittance of the sample solution with the same batch of water as a reference. 6.7.2.2 Result expression Express the calculation result to one decimal place. 6.7.3 Precision The absolute difference between two independent determination results which are obtained under repeatability conditions shall not exceed 1% of its arithmetic mean. 6.8 Sulfated ash 6.8.1 Reagents 6.8.1.1 Hydrochloric acid. 6.8.1.2 Concentrated sulfuric acid. 6.8.2 Instruments and apparatuses 6.8.2.1 Porcelain crucible: 50 mL. 6.8.2.2 High-temperature furnace: The temperature control range is 525 °C ± 25 °C. 6.8.2.3 Dryer: Use silica gel as desiccant. 6.8.2.4 Analytical balance: The accuracy is 0.01 mg. 6.8.3 Analysis steps 6.8.3.1 First, use hydrochloric acid to heat and boil the crucible; then, use running water to wash it; then, use distilled water to clean it. Place the cleaned crucible in a high- temperature furnace; burn at 525 °C ± 25 °C for 0.5 h; take it out and cool it at room temperature to below 200 °C; put it in a desiccator and cool it to room temperature; accurately weigh it; repeat the burning to constant weight (the difference between the two weighing before and after does not exceed 0.3 mg). 6.8.3.2 Weigh about 2 g of the sample (accurate to 0.000 1 g); put it into a crucible that has been ignited to constant weight; add 1 mL of concentrated sulfuric acid dropwise; turn it slowly to make it uniform; place it on an electric furnace to carefully heat it until it is completely carbonized. Then, put it into the high-temperature furnace and burn at 525 °C ± 25 °C; keep this temperature until all the carbonization disappears (at least 2 h). Take it out and cool it; add a few drops of concentrated sulfuric acid to wet the residue; put it back into the high-temperature furnace and burn it until it is completely ashed; take it out and cool it to below 200°C at room temperature; put it in a desiccator; 7.4 Type inspection The inspection items are all the items specified in the requirements of this document. Generally, the type inspection is carried out once every six months. In any of the following cases, the type inspection shall also be carried out: a) When there are major changes in raw and auxiliary materials; b) When there are changes on critical processes or equipment; c) When the new product is trial-manufactured, or the normal production product is stopped for three months and resumed; d) When the delivery inspection is significantly different from the previous type inspection result; e) When the national supervision and institution carries out a spot inspection according to relevant regulations. 7.5 Determination rules 7.5.1 When all inspection items of the sampled products meet the requirements, determine that the batch of products conforms to this document. 7.5.2 If one or two items of the inspection items do not meet the requirements, taken twice the number of samples from the same batch of products for re-inspection. The re- inspection results shall prevail. If there is still one non-compliance with the requirements, determine that the batch of products does not comply with this document. If there are three or more non-compliance indicators with requirements in the inspection results, determine that the batch of products does not comply with this document. 8 Marking, packaging, transportation and storage 8.1 Marking 8.1.1 The product classification shall be indicated on the label or instruction manual; for products with a DE value greater than or equal to 95%, the product name can be marked with "whole sugar powder". 8.1.2 The pictorial marking for handling of goods shall meet the requirements of GB/T 191. 8.2 Packaging 8.2.1 Packaging containers (bottles, barrels, bags, etc.) shall be clean and undamaged. 8.2.2 If tanker trucks are used to transport glucose syrup, special tankers shall be used. Appendix A (Informative) Determination of sugar boiling temperature A.1 Reagents and solutions A.1.1 Stanmer 5-degree No. I solution Weigh 20 g of nickel sulfate (NiSO4·7H2O); add 11 g of ammonium sulfate [(NH4)2SO4]; dissolve in water and dilute to 500 mL; shake well. A.1.2 Stanmer 5-degree No. II solution Weigh 20 g of cobalt chloride (CoCl2·6H2O); add 11 g of ammonium sulfate; dissolve in water and dilute to 200 mL; shake well. A.1.3 Stanmer 5-degree No. III solution Weigh 2 g of potassium dichromate (K3Cr2O7); add 11 g of ammonium sulfate; dissolve in water and dilute to 200 mL; shake well. A.1.4 Stanmer 5-degree stock solution Draw 44.0 mL of Stanmer 5-degree No. I solution, 14.1 mL of Stanmer 5-degree No. II solution, and 4.4 mL of Stanmer 5-degree No. III solution; mix well; add water and dilute to 200 mL, which is Stanmer 5-degree stock solution. A.2 Analysis steps A.2.1 Preparation of standard color solution Take 34 mL of Stanmer 5-degree stock solution in a 100 mL volumetric flask; add water to dilute to volume; shake well, and set aside. A.2.2 Determination and result expression Weigh 200 g of the sample into a 500 mL beaker; place it in a 1 000 W heating device with a voltage regulator (such as an electric furnace covered with asbestos mesh); heat the beaker evenly; insert a 0 °C ~ 200 °C mercury thermometer in the center of the beaker (the mercury head of the thermometer is about 0.5 cm from the bottom of the cup). When the syrup is slowly boiling, add two drops of vegetable oil; continue to heat and boil and observe carefully. When the color of the sample solution is consistent with the color of the standard color solution, record the temperature immediately, which is the sugar boiling temperature. The results obtained are expressed as integers. ......

BASIC DATA
Standard ID GB/T 20882.2-2021 (GB/T20882.2-2021)
Description (Translated English) Quality requirements for starch sugar -- Part 2: Glucose syrup and glucose syrup powder
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard X31
Classification of International Standard 67.180.20
Word Count Estimation 12,149
Date of Issue 2021-12-31
Date of Implementation 2022-07-01
Older Standard (superseded by this standard) GB/T 20885-2007
Drafting Organization Qinhuangdao Lihua Starch Co., Ltd.
Administrative Organization National Food Industry Standardization Technical Committee
Regulation (derived from) National Standard Announcement No. 17 of 2021
Proposing organization National Food Industry Standardization Technical Committee (SAC/TC 64)
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration