HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (1 Dec 2024)

GB/T 18431-2014 Related PDF English (GB/T 18431-2001)

GB/T 18431-2014 (GB/T18431-2014, GBT 18431-2014, GBT18431-2014) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB/T 18431-2014English225 Add to Cart 0-9 seconds. Auto delivery. Steam and hot water type lithium bromide absorption water chiller GB/T 18431-2014 Valid GBT 18431-2014
GB/T 18431-2001English639 Add to Cart 5 days Steam and hot water type lithium bromide absorption water chiller GB/T 18431-2001 Obsolete GBT 18431-2001
Buy with any currencies (Euro, JPY, KRW...): GB/T 18431-2014    Preview this PDF: GB/T 18431-2014



GB/T 18431-2014 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.200 J 73 Replacing GB/T 18431-2001 Steam and Hot Water Type Lithium Bromide Absorption Water Chiller ISSUED ON: JUNE 24, 2014 IMPLEMENTED ON: DECEMBER 21, 2014 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative References ... 4  3 Terms and Definitions ... 4  4 Types and Basic Parameters ... 5  5 Requirements ... 6  6 Test Methods ... 8  7 Inspection Rules ... 11  8 Marking, Packaging and Storage ... 12  Appendix A (Normative) Test Methods for Refrigerating Capacity ... 14  Appendix B (Normative) Calculation Method of Heat Loss Rate of Unit ... 19  Appendix C (Normative) Determination Method of Pressure Loss ... 21  Appendix D (Normative) Technical Requirements of Lithium Bromide Solution ... 23  Appendix E (Normative) Requirements for Cooling Water and Supplementary Water Quality ... 24  Steam and Hot Water Type Lithium Bromide Absorption Water Chiller 1 Scope This Standard specifies the terms and definitions, types and basic parameters, requirements, test methods, inspection rules, marking, packaging and storage of steam and hot water type lithium bromide absorption water chiller (hereinafter referred to as "unit"). This Standard is applicable to steam and hot water single-effect and double-effect units for central air conditioning and technology. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including all the amendments) applies. GB 151 Tubular Heat Exchangers GB/T 13306 Plates GB 18361 Safety Requirements of Lithium Bromide Absorption Water Chiller (Beater) GB/T 18430.1-2007 Water Chilling (Heat Pump) Packages Using the Vapor Compression Cycle - Part 1: Water Chilling (Heat Pump) Packages for Industrial & Commercial and Similar Application JB/T 4330-1999 Determination of Noise Emitted by Refrigerating and Air Conditioning Equipment JB/T 7249 Refrigerating Equipment - Terms 3 Terms and Definitions For the purposes of this document, the terms and definitions established in JB/T 7249 and the following ones apply. Paꞏm3/s. 5.2.2 Hydraulic pressure test All parts at the cold water side, cooling water side and heat source side of the unit shall be free from abnormal deformation and leakage. 5.3 Nominal condition performance 5.3.1 Refrigerating capacity The refrigerating capacity of the unit shall not be less than 95% of the nominal refrigerating capacity. 5.3.2 Consumption of heat source The consumption of heat source in specific refrigerating effect of the unit shall be in accordance with those specified in Table 1, and shall not be greater than 105% of the indicated value (when 95% of the indicated value of the unit is less than the value specified in Table 1). 5.3.3 Consumed electric power The consumed electric power of the unit shall not be greater than 105% of the indicated value. 5.3.4 Coefficient of performance (COP) The coefficient of performance of the unit shall not be greater than 95% of the indicated value. 5.3.5 Water-side pressure loss The pressure loss of cold water and cooling water of the unit shall not be greater than 110% of the indicated value. 5.4 Variable working condition performance The unit shall be able to work normally within the range specified in Table 2, and shall be subjected to variable working condition performance test according to interval value. Table 2 -- Application Scope Parameter Nominal condition Application scope Interval value Outlet temperature of cold water/℃ 7 5~10 1 Inlet temperature of cooling water/ ℃ 32 24~34 2 Steam single-effect Steam pressure/MPa 0.1 0.08~0.12 0.01 shall be dried with compressed air. 6.2.1.2.2 When the heat source side is designed and manufactured according to GB 151, hydraulic pressure test shall be carried out according to the requirements of GB 151. 6.2.2 Performance test under nominal condition 6.2.2.1 Refrigerating capacity Test shall be carried out according to Appendix A under the nominal condition specified in 4.3. 6.2.2.2 Consumption of heat source In the refrigerating capacity test, consumption of heat source is determined. If insulation construction is not performed for unit during the test, the unit heat loss shall be obtained according to Appendix B; the consumption of heat source shall be corrected according to Appendix A. 6.2.2.3 Consumed electric power When refrigerating capacity test is carried out, the input electric power of the unit shall be determined. 6.2.2.4 Water-side pressure loss The unit operates under nominal condition; after the determination of refrigerating capacity becomes stable, the pressure loss of unit at cold water side and cooling water side shall be determined according to Appendix C. 6.2.3 Test under variable working conditions The unit is subjected to test under variable working conditions by changing certain parameter separately according to the application scope and interval value specified in Table 2 with other conditions kept as those under the nominal condition; the test results shall be plotted into curve or compiled into table. 6.2.4 Partial load test Under the partial load condition specified in 5.5, refrigerating capacity and corresponding consumption of heat source shall be determined according to Appendix A. 6.2.5 Noise test The unit operates under nominal condition and is subjected to noise measurement 8 Marking, Packaging and Storage 8.1 Marking 8.1.1 Permanent nameplate shall be set at the obvious position of each unit; the nameplate shall meet the requirements of GB/T 13306 and its contents shall include: a) Name and trademark of manufacturer; b) Product model and name; c) Main parameters (refrigerating capacity, outlet temperature of cold water, cold water flow capacity, inlet temperature of cooling water, cooling water flow, heat source parameters and consumption, power supply, etc.); d) Factory number of product; e) Manufacture date. 8.1.2 Delivery document Each unit shall be accompanied with the following documents: a) Quality certificate, which shall include: 1) Product model and name; 2) Factory number of product; 3) Inspection conclusion; 4) Inspector's signature or seal; 5) Inspection date. b) Installation and operation instructions, which includes: 1) Product model and name; 2) Structural diagram, electrical diagram and wiring diagram of product; 3) Installation instructions and requirements; 4) Operating instructions and precautions of repair and maintenance. c) Packing list. 8.2 Packaging In Formulae (A.2)~(A.5): Qi - the heat consumption of heat source, kW; qms - the steam consumption, kg/h; hs1 - the specific enthalpy of steam, kJ/kg; hs2 - the specific enthalpy of condensation water, kJ/kg; qvk - the volume flow of hot water, m3/h; Ck - the specific heat capacity of hot water at mean temperature, kJ/(kgꞏ℃); ρk - the density of hot water, kg/m3; tk1 - the inlet temperature of hot water, ℃; tk2 - the outlet temperature of hot water, ℃; L - the heat loss rate of unit calculated according to Appendix B. A.5.3 Heat discharged by cooling water The heat discharged by cooling water shall be calculated according to Formula (A.6): Qw=(1/3 600)qvwCwρw(tw2-tw1) …………….……………………………… (A.6) Where, Qw - the heat discharged by cooling water, kW; qvw - the volume flow of cooling water, m3/h; Cw - the specific heat capacity of cooling water at mean temperature, kJ/(kgꞏ℃); ρw - the density of cooling water, kg/m3; tw1 - the inlet temperature of cooling water, ℃; tw2 - the outlet temperature of cooling water, ℃. A.5.4 Heat balance checking The heat balance deviation of unit shall be calculated according to Formula (A.7): 100%C i w Q Q P Q      …………….……………………………… (A.7) Appendix B (Normative) Calculation Method of Heat Loss Rate of Unit B.1 Calculation of heat loss The heat loss of unit shall be calculated according to Formulae (B.1) and (B.2): Q0=Ah(t0-ta) …………….……………………………… (B.1) Q1=A(t0-ta)/(1/h+δ/λ) …………….……………………………… (B.2) Where, Q0 - the heat loss prior to insulation construction, kW; Q1 - the heat loss after insulation construction, kW; A - the surface area, m2; h - the surface heat transfer coefficient, kW/(m2ꞏK), take h=11.6×10-3 kW/(m2ꞏK); t0 - the surface temperature, ℃; ta - the environment temperature, ℃, ta=20℃; δ - the thickness of thermal insulation material, m; λ - the thermal conductivity coefficient of thermal insulation material, kW/(mꞏK). B.2 Calculation of heat loss rate B.2.1 The heat loss rate of unit shall be calculated according to Formula (B.3): 0 1 Q Q  …………….……………………………… (B.3) Where, L - the heat loss rate; Q0 - the heat loss prior to insulation construction, kW; Q1 - the heat loss after insulation construction, kW; Qi - the heat consumption of heat source, kW. ......

BASIC DATA
Standard ID GB/T 18431-2014 (GB/T18431-2014)
Description (Translated English) Steam and hot water type lithium bromide absorption water chiller
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard J73
Classification of International Standard 27.200
Word Count Estimation 21,260
Date of Issue 2014/6/24
Date of Implementation 2014/12/31
Older Standard (superseded by this standard) GB/T 18431-2001
Quoted Standard GB 151; GB/T 13306; GB 18361; GB/T 18430.1-2007; JB/T 4330-1999; JB/T 7249
Drafting Organization Shuangliang saving system shares Co., Ltd.
Administrative Organization National Standardization Technical Committee refrigeration and air conditioning equipment
Regulation (derived from) National Standards Bulletin No. 14 of 2014
Proposing organization China Machinery Industry Federation
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the steam and hot water type lithium bromide absorption chillers (hereinafter referred to as "units") terms and definitions, types and basic parameters, requirements, test methods, inspection rules, marking, packaging and storage.

BASIC DATA
Standard ID GB/T 18431-2001 (GB/T18431-2001)
Description (Translated English) Steam and hot water type lithium bromide absorption water chiller
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard J73
Classification of International Standard 27.200
Word Count Estimation 16,121
Date of Issue 2001-08-30
Date of Implementation 2002-04-01
Quoted Standard GB 151-1999; GB 9969.1-1998; GB/T 13306-1991; GB/T 14436-1993; GB 18361-2001; JB/T 4330-1999; JB/T 7249-1994;
Adopted Standard JIS B8622-1994; NEQ
Drafting Organization Air Conditioning Equipment Co., Ltd. Jiangsu Shuangliang
Administrative Organization National Standardization Technical Committee refrigeration equipment
Proposing organization China Machinery Industry Federation
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China
Summary This standard specifies: steam and hot water lithium bromide absorption chillers definition, types and basic parameters, technical requirements, test methods, inspection rules, marking, packaging and storage. This standard applies to: air conditioning or process steam and hot water single and double effect absorption chillers. Steam and hot water lithium bromide absorption heat pump should also refer to the use.