Sterilization of health care products -- Radiation -- Part 3: Guidance on dosimeter aspects
|
GB/T 18280.3-2015
| Valid |
GBT 18280.3-2015
|
Buy with any currencies (Euro, JPY, KRW...): GB/T 18280.3-2015 Preview this PDF: GB/T 18280.3-2015
GB/T 18280.3-2015: PDF in English (GBT 18280.3-2015) GB/T 18280.3-2015
GB
NATIONAL STANDARD OF THE
PEOPLE'S REPUBLIC OF CHINA
ICS 11.080.01
C 47
GB/T 18280.3-2015 / ISO 11137-3.2006
Partly replacing GB 18280-2000
Sterilization of health care products - Radiation –
Part 3. Guidance on dosimetric aspects
(ISO 11137-3.2006, IDT)
ISSUED ON. DECEMBER 31, 2015
IMPLEMENTED ON. JANUARY 1, 2018
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3
Introduction ... 5
1 Scope ... 6
2 Normative references ... 6
3 Terms and definitions ... 6
4 Measurement of dose ... 7
5 Selection and calibration of dosimetry systems ... 7
6 Establishing the maximum acceptable dose ... 8
7 Establishing the sterilization dose ... 8
8 Installation qualification ... 10
9 Operational qualification ... 11
10 Performance qualification ... 17
11 Routine monitoring and control ... 21
Annex A (informative) Mathematical modelling ... 23
Bibliography ... 27
Foreword
GB 18280 consists of the following parts, under the general title Sterilization of health
care products - Biological indicators.
- Part 1. Requirements for development, validation and routine control of a
sterilization process for medical devices;
- Part 2. Establishing the sterilization dose;
- Part 3. Guidance on dosimetric aspects.
This Part is Part 3 of GB 18280.
This Part is drafted in accordance with the rules given in GB/T 1.1-2009.
This Part partly replaces GB 18280-2000 “Sterilization of health care products -
Requirement for validation and routine control - Radiation sterilization”. Compared with
GB 18280-2000, this Part was developed from Annex C of GB 18280-2000, main
technical content changes in this Part are as follows.
- ADD the introduction to sterilization dose;
- ADD the requirements for Installation Qualification, Operational Qualification
and Performance Qualification;
- ADD the requirements for routine monitoring and control.
This Part uses translation method to identically adopt ISO 11137-3.2006 “Sterilization
of health care products - Radiation - Part 3. Guidance on dosimetric aspects” (English
version).
China’s documents that are identical to the International documents normatively
referenced in this Part are as follows.
- GB 18280.1-2015 Sterilization of health care products - Radiation - Part 1.
Requirements for development, validation and routine control of a sterilization
process for medical devices (ISO 11137-1.2006, IDT)
- GB 18280.2-2015 Sterilization of health care products - Radiation - Part 2.
Establishing the sterilization dose (ISO 11137-2.2006, IDT)
Attention is drawn to the possibility that some of the elements of this document may
be the subject of patent rights. The issuing organizations of this document shall not be
held responsible for identifying any or all such patent rights.
This Part was proposed by State Food and Drug Administration.
This Part shall be under the jurisdiction of National Technical Committee on
Sterilization Techniques and Equipment of Standardization Administration of China
(SAC/TC 200).
Drafting organizations of this Part. Beijing Radiation Application Research Center,
Shenzhen JPY Ion-tech Co., Ltd., Guangzhou Medical Devices Quality Surveillance
and Test Institute of State Food and Drug Administration.
Main drafters of this Part. Hu Jinhui, Chen Qiang, Wu Weirong, Zeng Mingsheng, Bao
Yu and Hu Yang.
The previous edition of the standard replaced by this Part is as follow.
- GB 18280-2000.
Sterilization of health care products - Radiation –
Part 3. Guidance on dosimetric aspects
1 Scope
This Part of GB/T 18280 gives guidance on the requirements in GB 18280 parts 1 and
2 relating to dosimetry. Dosimetry procedures related to the development, validation
and routine control of a radiation sterilization process are described.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 11137-1 Sterilization of health care products - Radiation - Part 1. Requirements
for development, validation and routine control of a sterilization process for medical
devices
ISO 11137-2.2006 Sterilization of health care products - Radiation - Part 2.
Establishing the sterilization dose
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11137-1,
ISO 11137-2 and the following apply.
3.1
dosimetry system
Interrelated elements used for determining absorbed dose, including dosimeters,
instruments, associated reference standards and procedures for their use.
[ISO/TS 11139.2005]
[19] SHARPE, P. and MILLER, A. Guidelines for the Calibration of Dosimeters for use
in Radiation Processing. NPL Report CIRM 29, National Physical Laboratory,
Teddington, TW11 0LW, UK (1999)
[20] Panel on Gamma and Electron Irradiation, Guidance Notes on the Dosimetric
Aspects of Dose-setting Methods, The Panel on Gamma & Electron Irradiation,
212 Piccadilly, London, W1J 9HG, UK (1996)
[21] Panel on Gamma and Electron Irradiation, Discussion Paper on Uncertainties in
Routine Dosimetry for Gamma and EB Plants, The Panel on Gamma & Electron
Irradiation, 212 Piccadilly, London, W1J 9HG, UK (2002)
......
Standard ID | GB/T 18280.3-2015 (GB/T18280.3-2015) | Description (Translated English) | Sterilization of health care products -- Radiation -- Part 3: Guidance on dosimeter aspects | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | C47 | Classification of International Standard | 11.080.01 | Word Count Estimation | 17,177 | Date of Issue | 2015-12-31 | Date of Implementation | 2018-01-01 | Older Standard (superseded by this standard) | GB 18280-2000 | Quoted Standard | ISO 11137-1; ISO 11137-2-2006 | Adopted Standard | ISO 11137-3-2006, IDT | Drafting Organization | Beijing Applied Research Center of Radiation | Administrative Organization | National Disinfection Technology and Equipment Standardization Technical Committee | Regulation (derived from) | State Standard Announcement 2015 No.43 | Proposing organization | State Food and Drug Administration | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the dosimetry procedures associated with the development, validation and routine control of radiation sterilization processes. |
|