GB/T 11024.2-2019 (GB/T11024.2-2019, GBT 11024.2-2019, GBT11024.2-2019) & related versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | See Detail | Status | Similar PDF |
GB/T 11024.2-2019 | English | 90 |
Add to Cart
|
0-9 seconds. Auto delivery.
|
Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V -- Part 2: Ageing testing
|
GB/T 11024.2-2019
| Valid |
GBT 11024.2-2019
|
GB/T 11024.2-2001 | English | 359 |
Add to Cart
|
3 days
|
Shunt capacitors for a.c. power systems having a rated voltage above 1 kV -- Part 2: Endurance testing
|
GB/T 11024.2-2001
| Obsolete |
GBT 11024.2-2001
|
Buy with any currencies (Euro, JPY, KRW...): GB/T 11024.2-2019 Preview this PDF: GB/T 11024.2-2019
GB/T 11024.2-2019: PDF in English (GBT 11024.2-2019) GB/T 11024.2-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 31.060.70
K 42
Replacing GB/T 11024.2-2001
Shunt capacitors for a.c. power systems having a
rated voltage above 1000 V - Part 2: Ageing testing
(IEC/TS 60871-2:2014, Shunt capacitors for a.c. power systems having
a rated voltage above 1 000 V - Part 2: Endurance testing, MOD)
ISSUED ON: MARCH 25, 2019
IMPLEMENTED ON: OCTOBER 01, 2019
Issued by: State Administration for Market Regulation;
Standardization Administration of the People’s Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 6
2 Normative references ... 6
3 Terms and definitions ... 6
4 Quality requirements and tests ... 6
Appendix A (Normative) Comparable component design and test unit design
requirements ... 9
Foreword
GB/T 11024, Shunt capacitors for a.c. power systems having a rated voltage
above 1 000 V, is divided 4 parts.
-- Part 1: General;
-- Part 2: Ageing testing;
-- Part 3: Protection of shunt capacitors and shunt capacitor banks;
-- Part 4: Internal fuses.
This Part is the 2nd part of GB/T 11024.
This Part was drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/T 11024.2-2001, Shunt capacitors for a.c. power systems
having a rated voltage above 1 kV. Part 2: Endurance testing; compared with
GB/T 11024.2-2001, the major technical changes are as follow:
-- Change the name of this Part from “Endurance testing” to “Ageing testing”;
-- Delete the “overvoltage cycle test” in the scope (see Chapter 1, Chapter 1
of version 2001);
-- Move terms and definitions to GB/T 11024.1;
-- Move the overvoltage cycle test and Appendix A “Overvoltage waveform”
which have been rewritten and adjusted from this Part to GB/T 11024.1,
as a type test project;
-- Modify the test requirements for initial capacitance and dielectric loss
tangent measurements (see 4.3.1, 2.1.2.3 of version 2001);
-- Move Appendix B, “Definition of component and capacitor case dimensions”
to GB/T 11024.1.
This Part uses the redrafting method to modify the use of IEC/TS 60871-2: 2014
"Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V
- Part 2: Endurance testing”.
The technical differences between this Part and IEC/TS 60871-2:2014 and their
reasons are as follows:
-- With regard to the normative references, this Part makes technical
adjustments to adapt to the technical conditions of China. The
Shunt capacitors for a.c. power systems having a
rated voltage above 1 000 V - Part 2: Ageing testing
1 Scope
This Part of GB/T 11024 specifies the requirements for the ageing testing of
shunt capacitors for a.c. power systems having a rated voltage above 1 000 V.
This Part applies to capacitors in accordance with GB/T 11024.1.
2 Normative references
The following documents are indispensable for the application of this document.
For dated references, only the dated version applies to this document. For
undated references, the latest edition (including all amendments) applies to this
document.
GB/T 11024.1-2019, Shunt capacitors for a.c. power systems having a rated
voltage above 1000V. Part 1: General (IEC 60871-1:2014, MOD)
JB/T 8957-1999, Method for verifying accuracy of tau delta measurements
applicable to capacitors (idtIEC60996:1989)
3 Terms and definitions
Terms and definitions determined by GB/T 11024.1-2019 are applicable to this
document.
4 Quality requirements and tests
4.1 Test requirements and overall objectives
The ageing testing is a special test to verify that the ageing degree that is
caused by increasing test voltage at the rising temperatures does not cause
premature breakdown of the dielectric. It is a means to ensure that the base
material is properly selected and that it does not undergo any rapid ageing. This
test should not be considered as a tool to make any accurate assessment of
the dielectric life characteristics. To this end, manufacturers shall pay attention
to various types of research and development activities.
The ageing testing shall be performed as a special test by the manufacturer for
a particular dielectric system, i.e. not for capacitors of each specific rated value.
f) the length of the component (effective aluminum foil width) is allowed to
vary within 50% ~ 400%; the unfolded length of the component (effective
aluminum foil length) is allowed to vary within 30% ~ 300%.
A.2 Test unit design
If the following requirements are met, the test unit is considered to be
comparable to the production unit:
a) components that meet the requirements of A.1 shall be assembled in the
same manner as the production unit; the insulation between the
components shall be the same or thinner; the components shall be
pressed in the same manner; the compression factor shall be within the
manufacturing tolerance.
b) the number of connected test unit components shall be not less than 4, so
that the capacity under rated voltage (50 Hz) is not less than 100 kvar. All
connected components shall be placed next to each other.
Note 1: The connected components can be connected in series and in
parallel in any way to suit the test equipment.
c) the connections outside the test components can be enlarged, so as to
cope with the increase in current that is caused by the parallel connection
of some components.
d) the thickness of the insulation-to-case shall be the same or thicker.
Note 2: This requirement is to ensure that the drying and dipping
conditions are the same as those of the production unit. The
electrical resistance requirements of the insulation-to-case are
tested in accordance with the tests in Chapters 10 and 15 of
GB/T 11024.1-2019.
e) The height deviation of the casing shall be ±20% compared to the
production unit; the length and width deviation of the casing shall be ±50%.
Note 3: In order to allow component size changes, the range of the above
casing dimensions is necessary.
The outer casing materials shall be of the same type (metal, polymer, etc.),
but the topcoat can be omitted or can be different.
To accommodate the test voltage and/or test current, the design of the
bushing and the number of bushings can be adjusted.
f) The drying and dipping processes shall be the same as the normal
production process.
......
Standard ID | GB/T 11024.2-2019 (GB/T11024.2-2019) | Description (Translated English) | Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V -- Part 2: Ageing testing | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K42 | Classification of International Standard | 31.060.70 | Word Count Estimation | 6,663 | Date of Issue | 2019-03-25 | Date of Implementation | 2019-10-01 | Drafting Organization | Xi'an High Voltage Electric Apparatus Research Institute Co., Ltd., Shenzhen Sanhe Power Technology Co., Ltd., Wuxi Sunking Power Capacitor Co., Ltd., New Northeast Electric Group Power Capacitor Co., Ltd., Xi'an ABB Power Capacitor Co., Ltd., Xi'an Xidian Power Capacitor Co., Ltd. , Guilin Power Capacitor Co., Ltd., Xiamen Farah Electronics Co., Ltd., Wujiang Suhang Electric Co., Ltd., State Grid Zhejiang Electric Power Co., Ltd. Electric Power Research Institute, State Grid Zhejiang Electric Power Co., Ltd. Shaoxing Power Supply Company, Anhui Huawei New Energy Co., Ltd., Shanghai Cooper Power Capacitor Co., Ltd., Shanghai Siyuan Power Capacitor Co., Ltd., State Grid Anhui Electric Power Co., Ltd. Electric Power Research Institute, Herong Electric Co., Ltd., Nissin Electric (Wuxi) Co., Ltd., Anhui Yuanguang | Administrative Organization | National Technical Committee for Standardization of Power Capacitors (SAC/TC 45) | Proposing organization | China Electrical Equipment Industry Association | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
|