HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (5 Oct 2024)

GB 5009.34-2022 related PDF English

GB 5009.34-2022 (GB5009.34-2022) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB 5009.34-2022English215 Add to Cart 0-9 seconds. Auto delivery. National food safety standard - Determination of sulfur dioxide in foods GB 5009.34-2022 Valid GB 5009.34-2022
GB 5009.34-2016English70 Add to Cart 0-9 seconds. Auto delivery. National Food Safety Standard -- Determination of sulfur dioxide in food stuffs GB 5009.34-2016 Obsolete GB 5009.34-2016
GB/T 5009.34-2003English70 Add to Cart 0-9 seconds. Auto delivery. Determination of sulphite in foods GB/T 5009.34-2003 Obsolete GBT 5009.34-2003
GB/T 5009.34-1996English199 Add to Cart 2 days Method for determination of sulphite in foods GB/T 5009.34-1996 Obsolete GBT 5009.34-1996
GB 5009.34-1985English199 Add to Cart 2 days Method for determination of sulphite in foods GB 5009.34-1985 Obsolete GB 5009.34-1985
Buy with any currencies (Euro, JPY, KRW...): GB 5009.34-2022    Preview this PDF: GB 5009.34-2022



GB 5009.34-2022: PDF in English
GB 5009.34-2022 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA National food safety standard - Determination of sulfur dioxide in foods ISSUED ON: JUNE 30, 2022 IMPLEMENTED ON: DECEMBER 30, 2022 Issued by: National Health Commission of the People's Republic of China; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Principle ... 4  3 Reagents and materials ... 4  4 Instruments and equipment ... 5  5 Analysis steps ... 5  6 Presentation of analysis results ... 7  7 Precision ... 7  8 Detection limit and quantification limit ... 7  9 Principle ... 8  10 Reagents and materials ... 8  11 Instruments and equipment ... 9  12 Analysis steps ... 9  13 Presentation of analysis results ... 10  14 Precision ... 11  15 Detection limit and quantification limit ... 11  16 Principle ... 11  17 Reagents and materials ... 12  18 Instruments and equipment ... 12  19 Analysis steps ... 12  20 Presentation of analysis results ... 14  21 Precision ... 14  22 Detection limit and quantification limit ... 14  Annex A Schematic diagram of distillation device for acid-base titration ... 16  Annex B Schematic diagram of steam distillation device ... 17  Annex C Typical spectrum of sulfur dioxide standard working solution ... 18  National food safety standard - Determination of sulfur dioxide in foods 1 Scope This document specifies the determination method of sulfur dioxide in foods. Method One: Acid-base titration method is applicable to the determination of sulfur dioxide in foods. Method Two is Spectrophotometry. Direct extraction method is suitable for the determination of sulfur dioxide in white sugar and white sugar products, starch and starch products and raw wet flour products. Nitrogen-filled steam extraction method is suitable for the determination of sulfur dioxide in wine and brown sugar. Method Three: Ion chromatography is applicable to the determination of sulfur dioxide in foods. Method One -- Acid-base titration method 2 Principle Use nitrogen-filled steaming method to treat the specimen. After the specimen is acidified, under heating conditions, a series of substances such as sulfites release sulfur dioxide. Use hydrogen peroxide solution to absorb the distillate. Sulfur dioxide is dissolved in the absorption liquid and oxidized to form sulfuric acid. Use standard sodium hydroxide solution to titrate. Calculate the content of sulfur dioxide in the specimen according to the consumption of sodium hydroxide standard solution. 3 Reagents and materials Unless otherwise stated, the reagents used in this method are all analytically pure; the water is grade three water specified in GB/T 6682. 3.1 Reagents 3.1.1 Hydrogen peroxide (H2O2): 30%. 3.1.2 Absolute ethanol (C2H5OH). 3.1.3 Sodium Hydroxide (NaOH). 3.1.4 Methyl red (C15H15N3O2). Take specimens of beer, wine, fruit wine, other fermented wine, prepared wine, and beverages. The sampling volume shall be greater than 1L. For packaging specimens such as bagged specimens and bottled specimens, at least 3 packages (same batch or number) shall be collected. Put all liquids in one container. Mix well. Seal and mark for testing. 5.1.2 Solid specimen Take specimens of grain processed products, solid condiments, biscuits, potato products, candy products (including chocolate and products), substitute tea, pickled vegetables, dried vegetable products, edible mushroom products, other vegetable products, candied fruit, dried fruit products, roasted seeds and nuts and nut products (baked, fried, other), sugar, dried aquatic products, cooked animal aquatic products, edible starch, starch products, starch sugar, non-fermented soy products, vegetables, fruits, seawater products, raw and dried nuts and seeds. The sampling weight shall be greater than 600g. According to the different properties and characteristics of specific products, conduct sampling directly. Completely mix well or use a suitable pulverizing means such as a grinder to grind the edible part. Completely mix well. Store in a clean sample bag. Seal and mark for testing. 5.1.3 Semi-fluid specimen For packaging specimens such as bagged specimens and bottled specimens, at least 3 packages (same lot or number) need to be collected. For sauces, canned fruits and vegetables and other semi-fluid specimens, the sampling amount shall be greater than 600g. Use the tissue masher to mash and mix well. Store in a clean sample bag. Seal and mark for testing. 5.2 Specimen determination Take 20g~100g of solid or semi-fluid specimen (to the nearest of 0.01g; the sampling amount depends on the content). Take 20mL(g)~200mL(g) of liquid specimen. Place the weighed specimen in the round bottom flask A in Figure A.1. Add 200mL~500mL of water. Install the device. Turn on the switch of the reflux condenser to supply water (condensate temperature < 15°C). Place the glass tube connected to the port E at the upper end of the condenser tube at the bottom of the 100mL conical flask. Add 50mL of 3% hydrogen peroxide solution to the conical flask as the absorption solution (the end of the glass tube shall be below the liquid level of the absorption solution). Add 3 drops of 2.5g/L methyl red ethanol solution indicator to the absorption solution. Use sodium hydroxide standard solution (0.01mol/L) to titrate until it turns yellow as the end point (if it exceeds the end point, the absorption solution shall be discarded). Turn on nitrogen. Adjust the gas flow meter to 1.0L/min~ 2.0L/min. Open the plunger of the separatory funnel C. Make 10mL of 6mol/L hydrochloric acid solution quickly flow into the steamer. Immediately heat the solution in the flask to boiling. Keep it slightly boiled for 1.5h. Stop heating. Cool the absorption solution and shake well. Use sodium hydroxide standard solution (0.01mol/L) to titrate till it turns yellow and not fade for 9 Principle The sample is directly soaked in methyl acetate buffer absorbent or nitrogen-filling with acid and steamed-released sulfur dioxide is absorbed by the formaldehyde solution. Generate stable hydroxymethanesulfonic acid addition compound. Under acidic conditions, with pararosaniline hydrochloride, generate a blue-violet complex. The absorbance value of this complex is proportional to the concentration of sulfur dioxide. 10 Reagents and materials Unless otherwise stated, the reagents used in this method are all analytically pure, and the water is grade three water specified in GB/T 6682. 10.1 Reagents 10.1.1 Ammonium sulfamate (H6N2O3S). 10.1.2 Disodium EDTA (C10H14N2Na2O8). 10.1.3 Formaldehyde (CH2O): 36%~38%; there shall be no polymer (no precipitation and no separation of the solution). 10.1.4 Potassium hydrogen phthalate (KHC8H4O4). 10.1.5 2% pararosaniline hydrochloride (C20H20ClN3) solution. 10.1.6 Glacial acetic acid (C2H4O2). 10.1.7 Phosphoric acid (H3PO4). 10.2 Reagent preparation 10.2.1 Sodium hydroxide solution (1.5mol/L): Weigh 6.0g of NaOH (3.1.3). Dissolve in water and dilute to 100mL. 10.2.2 Disodium EDTA solution (0.05mol/L): Weigh 1.86g of disodium ethylenediaminetetraacetate (abbreviated as EDTA-2Na). Dissolve in water and dilute to 100mL. 10.2.3 Formaldehyde buffered absorption stock solution: Weigh 2.04g of potassium hydrogen phthalate. Dissolve in a small amount of water. Add 5.5mL of 36%~38% formaldehyde solution, 20.0mL of 0.05mol/L EDTA-2Na solution. Mix well. Add water to dilute and set volume to 100mL. Store in a refrigerator to keep refrigerated. 10.2.4 Formaldehyde buffered absorption solution: Measure an appropriate amount of formaldehyde buffered absorption stock solution. Use water to dilute 100 times. Prepare 17 Reagents and materials Unless otherwise specified, the reagents used in this method are all analytically pure, and the water is grade one water specified in GB/T 6682. 17.1 Standard product Sulfate ion standard solution (1000μg/mL): with national certification and awarded the standard material certificate. 17.2 Materials Microporous membrane: 0.45μm. 18 Instruments and equipment 18.1 Steam distillation device or equivalent steam distillation equipment: equipped with gas flow meter. See Annex B for the schematic diagram of the device. 18.2 Ion chromatograph: equipped with conductivity detector and suppressor. 19 Analysis steps 19.1 Specimen preparation Same with 5.1. 19.2 Specimen processing 19.2.1 Solid or semi-fluid specimen Weigh 10g of solid or semi-fluid specimen (to the nearest of 0.01g). Place in the round bottom flask D in Figure B.1. Add 50mL of water. Shake it to evenly disperse. Turn on nitrogen protection. Control its flow to 1.0L/min~ 2.0L/min. Connect to the steam distillation bottle A. In the absorption bottle H (a 100mL Nessler colorimetric tube), add 20mL of 3% hydrogen peroxide solution (3.2.1) as the absorption solution. The lower end of the absorption tube is inserted below the liquid level of the absorption solution. In bottle D, quickly add 10mL of hydrochloric acid solution (6mol/L) (3.2.2) along the bottle wall. Quickly seal. Start the distillation. Keep bottle A boiling and adjust distillation power. Make the outflow rate of the distillate at the end of the absorption tube about 2mL/min. Distill until the total volume of the solution in bottle H is about 95mL (time is 30min~40min). Use water to wash the end tube. Transfer it to a 100mL volumetric flask. Use water to set volume to the scale. Shake well. Place for 1h. Filter with microporous membrane (0.45μm) to obtain the testing sample solution. Do not add the specimen to conduct the blank test in the same method. 19.2.2 Liquid specimen Accurately measure 10mL~50mL of liquid specimen or weigh 10g~50g of liquid specimen (to the nearest of 0.01g). When the liquid sampling is less than 50mL, add water to make up the volume to 50mL. The rest operation is same with 19.2.1. 19.3 Instrument reference conditions 19.3.1 Chromatographic column: A high-capacity anion exchange column that uses ethylvinylbenzene-divinylbenzene superporous emulsion gel polymer resin with alkanol quaternary ammonium as functional group as the packing material (packing material diameter is 9μm, 250mm×4mm) or equivalent column; Anion exchange column that the guard column uses the same packing material (packing material diameter is 13μm, 50mm×4mm). 19.3.2 Column temperature: 30°C. 19.3.3 Eluent: 20mmol/L potassium hydroxide solution (or equivalent eluent). 19.3.4 Flow rate: 1.0mL/min. 19.3.5 Suppressor: Anion suppressor. The suppressing current is 50mA (or equivalent suppressor). 19.3.6 Detector: Conductivity detector. The detection cell temperature is 35°C. 19.3.7 Injection volume: 100μL. 19.4 Preparation of standard curve Accurately pipette 5.00mL of sulfate ion standard solution. Place in a 50mL volumetric flask. Add water to set volume to the scale. From the above-mentioned solution, accurately pipette 0.10mL, 0.20mL, 0.50mL, 1.00mL, 2.00mL, 4.00mL. Put in 10mL volumetric flasks. Add water to set volume to the scale. Prepare the solutions that respectively contain 1.0μg/mL, 2.0μg/mL, 5.0μg/mL, 10.0μg/mL, 20.0μg/mL and 40.0μg/mL sulfate ions. Precisely absorb 100μL of sulfate ion standard solution. Conduct sequential injection from low concentration to high concentration. Obtain the chromatogram of the above concentration standard solution. Draw a standard curve with the sulfate ion concentration as the abscissa and the peak area or peak height as the ordinate. See Figure C.1 in Annex C for the chromatogram of the sulfate ion standard solution. 19.5 Determination of specimen solution Inject the test solution under the same chromatographic conditions as the calibration curve. The test solution is quantified by peak area or peak height. Obtain the sulfate ion ......

BASIC DATA
Standard ID GB 5009.34-2022 (GB5009.34-2022)
Description (Translated English) National food safety standard - Determination of sulfur dioxide in foods
Sector / Industry National Standard
Classification of Chinese Standard X09
Word Count Estimation 14,127
Date of Issue 2022-06-30
Date of Implementation 2022-12-30
Older Standard (superseded by this standard) GB 5009.34-2016
Administrative Organization National Health Commission
Issuing agency(ies) State Administration for Market Regulation