HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (12 Oct 2024)

GB 31604.20-2016 related PDF English

GB 31604.20-2016 (GB31604.20-2016) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB 31604.20-2016English70 Add to Cart 0-9 seconds. Auto delivery. Food contact materials -- Polymer materials -- Determination of vinyl acetate in food stimulants by gas chromatography/mass spectrometry GB 31604.20-2016 Valid GB 31604.20-2016
Buy with any currencies (Euro, JPY, KRW...): GB 31604.20-2016    Preview this PDF: GB 31604.20-2016



GB 31604.20-2016 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA National food safety standard - Food contact materials and products - Determination of vinyl acetate migration quantity ISSUED ON. OCTOBER19, 2016 IMPLEMENTED ON. APRIL 19, 2017 Issued by. National Health and Family Planning Commission of the PRC Table of Contents Foreword . 3  1 Scope .. 4  2 Principles .. 4  3 Reagents and materials . 4  4 Instrument and equipment .. 5  5 Analytical procedures .. 5  6 Analysis results expression . 7  7 Confirmatory test .. 7  8 Precision . 7  9 Others .. 7  Appendix A Vinyl acetate gas chromatogram .. 8  Appendix B Gas chromatography-mass spectrometry confirmation reference conditions .. 9  Appendix C Vinyl acetate chromatography-mass spectrometry diagram .. 11  National food safety standard - Food contact materials and products - Determination of vinyl acetate migration quantity 1 Scope This standard specifies determination method of vinyl acetate migration quantity in food contact materials and products. This standard applies to determination of vinyl acetate migration quantity in food contact materials and products. 2 Principles In the sample, after the vinyl acetate is leached from the food simulation soaking solution, use acetone to dilute it, and finally use gas chromatography to determine and external standard method to quantify. Once the sample is detected, it must be confirmed by gas chromatography - mass spectrometry. 3 Reagents and materials Unless otherwise indicated, the reagents used in this method are analytical grade, the water is the grade-1 water specified in GB/T 6682. The containers and transfer apparatuses in the test shall avoid using plastic materials. 3.1 Reagents 3.1.1 Acetone (C3H6O). It does not contain vinyl acetate. 3.1.2 Methanol (C2H4O). 3.1.3 Water-based, acidic, alcoholic, oil-based food simulants. The reagents used are in accordance with the provisions of GB 31604.1. 3.2 Reagent preparation 3.2.1 Water-based, acidic, alcoholic, oil-based food simulants. Operate according to GB 5009.156. 5.2 Preparation of standard working solution of food simulants that are water-based, acidic food, alcoholic, and oil-based Accurately PIPETTE 0 mL, 0.01 mL, 0.05 mL, 0.1 mL, 0.5 mL, 1.0 mL of vinyl acetate standard intermediate solution into 10 mL volumetric flask; USE acetone to dilute it; OBTAIN standard working solution with vinyl acetate concentration of 0.00 mg/L, 0.1 mg/L, L, 0.5 mg/L, 1.0 mg/L, 5.0 mg/L, 10.0 mg/L, respectively. In the same way, OBTAIN standard working solution of food simulants that are water-based, acidic food, alcoholic, and oil-based. 5.3 Gas chromatograph (GC) reference conditions The GC reference conditions are listed below. a) Chromatographic column. DB-5 quartz capillary column, column length 30 m, inner diameter 0.32 mm, film thickness 0.25 μm, or equivalent; b) Temperature programming. 35 °C (keep for 5 min), rising from 5 °C/min to 50 °C, rising from 40 °C/min to 250 °C (keep for 2 min); c) Inlet temperature. 250 °C; d) Injection mode. split injection (10.1), injection volume is 1 μL; e) Detector temperature. 300 °C; f) Carrier gas (N2) flow rate. 0.5 mL/min; g) Hydrogen flow rate. 30 mL/min; h) Air flow rate. 400 mL/min. 5.4 Determination 5.4.1 Sample determination TAKE a clean and dry 25 mL volumetric flask; ADD 1 g (accurate to 0.0001 g) of simulated food soaking solution after migration experiment; USE acetone to dilute it to the mark; MIX it uniformly for spare-use. USE micro-syringe to pipette respectively a certain amount of the above test solution; INJECT it into gas chromatograph. According to the above gas chromatographic conditions, REPEAT the determination twice. The gas chromatogram of vinyl acetate is shown in Figure A.1. 5.4.2 Blank Test Blank test refers to, except for not adding sample, use exactly the same analytical procedure, reagents and dosage, carry out parallel operation. Appendix B Gas chromatography-mass spectrometry confirmation reference conditions B.1 Gas chromatographic conditions The gas chromatographic conditions are listed below. a) Chromatographic column. Capillary column. DB-5 ms 30 m × 0.25 mm (inner diameter) × 0.25 μm, or equivalent; b) Temperature programming. 30 °C (keep for 4 min), rising from 5 °C/min to 50 °C, rising from 40 °C/min to 250 °C (keep for 2 min); c) Inlet temperature. 250 °C; d) GC-MS interface temperature. 280 °C; e) Carrier gas (He). 0.55 mL/min; f) Injection mode. split injection, split ratio is 10.1. B.2 Mass Spectrometry Conditions The mass spectrometry conditions are listed below. a) Ion source temperature. 230 °C; b) Quadrupole rod temperature. 150 °C; c) Ion source. EI source, ionization energy 70 eV; d) Quantitative ion. 43 m/z; e) Qualitative ion. 86,44 m/z. Note. For different mass spectrometers, the instrument parameters may be different. Before the determination, the mass spectrometry parameters shall be optimized to the best. B.3 Qualitative determination When determining the sample, dilute the sample solution appropriately, and determine the sample solution and standard working solution according to gas chromatography-mass spectrometry conditions. If it is confirmed that the ......

BASIC DATA
Standard ID GB 31604.20-2016 (GB31604.20-2016)
Description (Translated English) Food contact materials -- Polymer materials -- Determination of vinyl acetate in food stimulants by gas chromatography/mass spectrometry
Sector / Industry National Standard
Classification of Chinese Standard X09
Word Count Estimation 8,871
Date of Issue 2016-10-19
Date of Implementation 2017-04-19
Older Standard (superseded by this standard) SN/T 2333-2009
Regulation (derived from) State Health and Family Planning Commission Notice No.1516 of 2016

BASIC DATA
Standard ID ()
Description (Translated English) (Technical specifications for ceramic capacitive sensor type partial discharge monitoring devices of 35kV and below)
Sector / Industry Chinese Industry Standard
Date of Issue 2023-10-11
Date of Implementation 2024-04-11
Issuing agency(ies) National Energy Board

BASIC DATA
Standard ID ()
Description (Translated English) (Technical specifications for ceramic capacitive sensor type partial discharge monitoring devices of 35kV and below)
Sector / Industry Chinese Industry Standard
Date of Issue 2023-10-11
Date of Implementation 2024-04-11
Issuing agency(ies) National Energy Board