HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (1 Dec 2024)

GB 24330-2020 Related PDF English (GB 24330-2009)

GB 24330-2020 (GB24330-2020) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB 24330-2020English499 Add to Cart 5 days General security technical specification for domestic sanitary insecticide GB 24330-2020 Valid GB 24330-2020
GB 24330-2009English320 Add to Cart 0-9 seconds. Auto delivery. General security technical specification for domestic sanitary insecticide GB 24330-2009 Obsolete GB 24330-2009



GB 24330-2020 General security technical specification for domestic sanitary insecticide ICS 65:100:10 G25 National Standards of People's Republic of China Replace GB 24330-2009 General technical requirements for safety of household sanitary insecticides 2020-12-24 release 2022-01-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee Preface This standard was drafted in accordance with the rules given in GB/T 1:1-2009: This standard replaces GB 24330-2009 "General Technical Requirements for the Safety of Household Hygiene and Insecticide Products", and compared with GB 24330-2009, except In addition to editorial changes, the main technical changes are as follows: ---Modified the standard normative references (see Chapter 2, Chapter 2 of the:2009 edition); ---Modified the requirements for the active ingredient content and allowable fluctuation range (see Table 1, Table 1 of the:2009 edition); ---Modified the requirements for drug efficacy (see 4:4, 4:4 of the:2009 edition); --- Modified the requirements for thermal storage stability (see 4:5, 4:5 in:2009 edition); ---Modified the requirements for the minimum duration of the electric mosquito coil liquid (see 4:7, 4:7 of the:2009 edition); ---Added the requirement of methanol content in insecticidal aerosol (see 4:8); ---Added the requirements for sanitary indicators of repellent products (see 4:12); ---Added the safety requirements for clothing mothproofing agents (see 4:13); ---Modified the test method of active ingredient content and allowable fluctuation range (see 5:3,:2009 edition 5:3); ---Modified the test method of drug efficacy (see 5:4, 5:4 of the:2009 edition); ---Modified the test method of thermal storage stability (see 5:5, 5:5 of the:2009 edition); ---Modified the test method of soot amount (see 5:6, 5:6 of the:2009 edition); ---Modified the test method for the minimum duration of the electric mosquito coil liquid (see 5:7, 5:7 in the:2009 edition); ---Added the test method of methanol content in insecticidal aerosol (see 5:9); ---Modified the test method for the net content of insecticidal aerosol (see 5:11, 5:10 of the:2009 edition) ---Added the test method for the hygienic index of repellent products (see 5:13); ---Added a test method for the safety of clothing mothproofing agents (see 5:14); ---Modified the effective ingredient content test methods of Appendix A, Appendix B, Appendix C, and Appendix D; ---Deleted the test method for the amount of mosquito cigarette dust (Appendix E of the:2009 edition); ---The determination method of p-dichlorobenzene, o-dichlorobenzene and m-dichlorobenzene content has been added (see Appendix E); ---The test method of naphthalene, an anti-moth agent for clothing, has been added (see Appendix F): Please note that certain contents of this document may involve patents: The issuing agency of this document is not responsible for identifying these patents: This standard was proposed and managed by the Ministry of Industry and Information Technology of the People's Republic of China: The previous versions of the standard replaced by this standard are as follows: ---GB 24330-2009: General technical requirements for safety of household sanitary insecticides 1 Scope This standard specifies general safety requirements and tests for household hygiene and insecticide products related to personal health and environmental protection: method: This standard applies to sanitary insecticides used for household control of mosquitoes, flies, cockroaches and other pests: 2 Normative references The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article Pieces: For undated references, the latest version (including all amendments) applies to this document: GB/T 13917:1 Indoor efficacy test and evaluation of sanitary insecticides for pesticide registration Part 1: Propellants GB/T 13917:2 Indoor efficacy test and evaluation of sanitary insecticides for pesticide registration Part 2: Aerosol GB/T 13917:3 Indoor efficacy test and evaluation of sanitary pesticides for pesticide registration: Part 3: Smoke agents and smoke tablets GB/T 13917:4 Indoor efficacy test and evaluation of sanitary insecticides for pesticide registration: Part 4: Mosquito coils GB/T 13917:5 Indoor efficacy test and evaluation of sanitary insecticides for pesticide registration: Part 5: Electric mosquito coils GB/T 13917:6 Indoor efficacy test and evaluation of sanitary pesticides for pesticide registration: Part 6: Electric mosquito coil GB/T 13917:7 Indoor efficacy test and evaluation of sanitary pesticides for pesticide registration: Part 7: Bait GB/T 13917:8 Indoor efficacy test and evaluation of sanitary pesticides for pesticide registration: Part 8: Powders and pens GB/T 13917:9 Indoor efficacy test and evaluation of sanitary insecticides for pesticide registration: Part 9: Repellent GB/T 28015 Test method for smoke and dust of household sanitary insecticide products NY/T 1151:1-2015 Indoor efficacy test and evaluation of sanitary insecticides for pesticide registration Part 1: Mothproofing agents QB/T 4147 Mosquito repellent toilet water QB/T 4148 Cockroach bait for household hygiene and insecticide QB/T 4149 household hygiene insecticide products cockroach bait QB/T 4150 Household hygiene insecticide products cockroach incense Measures for the Metrological Supervision and Administration of Quantitative Package Commodities (Order No: 75 of the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China) Cosmetic Safety Technical Specification (2015 Edition) 3 Terms and definitions The following terms and definitions apply to this document: 3:1 Active ingredient Chemical ingredients with biological insecticidal activity: 3:2 Efficacy The product can achieve the effect of repelling (killing) mosquitoes (including flies, cockroaches, ants, etc:) under specified conditions and within specified time: 3:3 Mediannockdowntime KT50 Under the specified conditions, the time required for 50% of the test insects to be knocked down (ie fall down): ......


GB 24330-2009 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 65.100.10 G 25 General security technical specification for domestic sanitary insecticide ISSUED ON: SEPTEMBER 30, 2009 IMPLEMENTED ON: MAY 01, 2010 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 4  4 Requirements ... 5  5 Test methods ... 8  Annex A (normative) Method for determining content of active ingredients in mosquito coils ... 14  Annex B (normative) Method for determining content of active ingredients in electrothermal mosquito tablet incense ... 17  Annex C (normative) Method for determining content of active ingredients in electrothermal mosquito liquid incense ... 20  Annex D (normative) Method for determining content of active ingredients in insecticide aerosol ... 23  Annex E (normative) Method for determining amount of soot of mosquito coil ... 28  General security technical specification for domestic sanitary insecticide 1 Scope This Standard specifies general terms and definitions, requirements, test methods of domestic sanitary insecticide. This Standard is applicable to general requirements related to health, environmental safety of domestic sanitary insecticide. 2 Normative references The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB 13917.1~13917.7, Laboratory efficacy test methods and criterions of public health insecticides for pesticide registration GB/T 17322.1~17322.11, Laboratory efficacy criterions of public health insecticides for pesticide registration Order of the General Administration of Quality Supervision, Inspection and Quarantine (No.75) - “Measures for the Metrological Supervision and Administration of Quantitatively Packed Commodities” Order of the Ministry of Agriculture and Rural Affairs of the People’s Republic of China [2007] (No.10) - “Pesticide registration information requirements” 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 active ingredient Chemical composition with biological insecticidal activity. 3.2 efficacy Under the specified conditions and within the specified time, the effect of repelling (killing) mosquitoes (including flies, cockroaches, ants and so on) the product shall achieve. 3.3 median knockdown time, KT50 Under the specified conditions, the time required for 50% of the test insects to be knocked down (i.e., fall down). 3.4 minimum effective period The minimum effective time for the use of the traditional Chinese medicine liquid of electrothermal mosquito liquid incense and electric heater. 4 Requirements 4.1 Requirements for use of active ingredient It shall be the medicament that is registered for use in accordance with relevant national regulations. 4.2 Toxicology It shall meet the toxicological test requirements of the corresponding dosage form in the Order of the Ministry of Agriculture and Rural Affairs of the People’s Republic of China [2007] (No.10). 4.3 Active ingredient content and allowable fluctuation range 4.3.1 The content of active ingredients shall be clearly stated on the product packaging. 4.3.2 The allowable fluctuation range of active ingredient content is shown in Table 1 and the following regulations: a) For mosquito coil, cockroach, fly incense and other tobacco preparation products, the allowable fluctuation range of its active ingredient content shall not be higher than 40% of the indicated value and not lower than 20% of the indicated value; b) For electrothermal mosquito liquid incense, the allowable fluctuation range of its active ingredient content shall not be higher than 25% of the indicated value and not lower than 10% of the indicated value; c) Electrothermal mosquito tablet incense shall be marked (mg/piece). The 5.3 Active ingredient content and allowable fluctuation range 5.3.1 Visual inspection. 5.3.2 The content of active ingredients shall be tested in accordance with the provisions of Annex A, Annex B, Annex C, and Annex D (unlisted dosage form products shall be implemented according to the test methods in relevant national standards). 5.4 Efficacy 5.4.1 Sprays, aerosols, small aerosols, mosquito coils, electrothermal mosquito tablet incenses, electrothermal mosquito liquid incenses, cockroach poison baits shall be tested according to GB 13917.1 ~ 13917.7. 5.4.2 Toxic powder, poison pen and repellent are tested according to GB/T 17322.9 ~ 17322.10. 5.4.3 Unlisted dosage form products are implemented according to the methods in relevant national product standards. 5.5 Thermal storage stability 5.5.1 Mosquito coil Take one coil from the middle of one box of test samples to crush. Pass the 0.154mm (100 mesh/inch) standard sample sieve. Take half of it and seal it in a Teflon reagent bottle (the other half is tested for active ingredient content). Then place it in a thermostat at (54±2)°C for 14d. After taking out the sample, test and calculate the degradation rate according to the method for determining the content of active ingredient within 24h. 5.5.2 Electrothermal mosquito tablet incense The test sample shall be the electrothermal mosquito tablet incense in the same row as before storage. The test sample (with aluminum foil packaging) is placed in a (54±2)°C thermostatic chamber for 14d. After taking out the sample, test and calculate the degradation rate according to the method for determining the content of active ingredient within 24h. 5.5.3 Electrothermal mosquito liquid incense Take a part of a bottle of test sample as the active ingredient content. Screw the outer cover of the rest part into the original packaging. Then place in a (54±2)°C thermostatic chamber for 14d. After taking out the sample, test and calculate the degradation rate according to the method for determining the content of active ingredient within 24h. Liquid medicine is poured into a measuring cylinder or weighed with a balance. Read out the test value (measuring cylinder division value: 0.1mL; balance division value: 0.1g). 5.9 Internal pressure of insecticide aerosol 5.9.1 Instruments 5.9.1.1 Pressure gauge: range is 0~1.6MPa, accuracy is level 2.5. 5.9.1.2 Special joint. 5.9.1.3 Timer. 5.9.1.4 Constant temperature water bath: temperature control accuracy is ±2°C. 5.9.2 Test steps Correctly press the valve actuator according to product description requirements. Eliminate the air trapped in valves and straws. Then place the sample in a (55±2)°C water bath. Immerse the water to four-fifths of the height of the tank. Maintain it at the constant temperature for 30min. Wear thick leather gloves. Remove the sample and dry it quickly. Unplug the valve actuator. Align the pressure gauge inlet with the valve stem. Press hard. After the pressure gauge pointer stabilizes, write down the pressure gauge reading. The maximum value of three measurements shall prevail. 5.10 Net content of insecticide aerosol 5.10.1 Net volume of insecticide aerosol 5.10.1.1 Instruments 5.10.1.1.1 Glass aerosol test tube with scale: capacity is 90mL, minimum division value is 1mL. 5.10.1.1.2 Balance: division value is not less than 0.01g. 5.10.1.2 Test temperature The test temperature is (25±3)°C. 5.10.1.3 Test steps Take the sample and weigh its mass m3. Assemble the glass aerosol test tube. Use a valve without a straw. Wipe the glass aerosol test tube clean. First inject a proper amount of propellant, about 10mL. Then spray empty and weigh its mass m4. Annex A (normative) Method for determining content of active ingredients in mosquito coils A.1 Identification test This identification test can be carried out simultaneously with the determination of the content of active ingredients. Under the same chromatographic operating conditions, the relative difference between the retention time of a chromatographic peak in the sample solution and the retention time of the active ingredient in the standard shall be within 1.5%. A.2 Method summary The sample uses dibutyl phthalate or dipentyl phthalate as the internal standard. Conduct gas chromatography separation and determination on internal coated SE-54 capillary column. A.2.1 Instruments A.2.1.1 Gas chromatograph: with hydrogen flame ionization detector. A.2.1.2 Chromatography column: Φ0.25mm × 30m × 0.25μm, capillary column coated with SE-54. A.2.1.3 Micro syringe: 10μL. A.2.1.4 Ground-mouth triangular flask. A.2.1.5 Balance: division value is 0.1mg. A.2.1.6 Grinder. A.2.1.7 Sieve: standard sample sieve 0.154mm (100 mesh/inch). A.2.1.8 Filter paper. A.2.1.9 Oscillator. A.2.2 Reagents A.2.2.1 Internal standard substance: dibutyl phthalate or dipentyl phthalate, without interference impurities. A.2.2.2 Solvents: acetone, methanol (analytical reagent). Annex B (normative) Method for determining content of active ingredients in electrothermal mosquito tablet incense B.1 Identification test This identification test can be carried out simultaneously with the determination of the content of active ingredients. Under the same chromatographic operating conditions, the relative difference between the retention time of a chromatographic peak in the sample solution and the retention time of the active ingredient in the standard solution shall be within 1.5%. B.2 Method summary The sample uses dibutyl phthalate or diisooctyl phthalate as the internal standard substance. Conduct gas chromatography separation and determination on internal coated SE-54 capillary column. B.2.1 Instruments B.2.1.1 Gas chromatograph: with hydrogen flame ionization detector. B.2.1.2 Chromatography column: Φ0.25mm × 30m × 0.25μm, capillary column coated with SE-54. B.2.1.3 Micro syringe: 10μL. B.2.1.4 Ground-mouth test tube. B.2.1.5 Ground-mouth triangular flask. B.2.1.6 Balance: division value is 0.1mg. B.2.2 Reagents B.2.2.1 Internal standard substance: dibutyl phthalate or diisooctyl phthalate, without interference impurities. B.2.2.2 Solvents: acetone, methanol (analytical reagent). B.2.2.3 Standard samples: allethrin, propargyl, etc. B.2.3 Gas chromatography conditions Annex C (normative) Method for determining content of active ingredients in electrothermal mosquito liquid incense C.1 Identification test This identification test can be carried out simultaneously with the determination of the content of active ingredients. Under the same chromatographic operating conditions, the relative difference between the retention time of a chromatographic peak in the sample solution and the retention time of the active ingredient in the standard solution shall be within 1.5%. C.2 Method summary The sample uses dibutyl phthalate as the internal standard substance. Conduct gas chromatography separation and determination on internal coated SE-54 capillary column. C.2.1 Instruments C.2.1.1 Gas chromatograph: with hydrogen flame ionization detector. C.2.1.2 Chromatography column: Φ0.25mm × 30m × 0.25μm, capillary column coated with SE-54. C.2.1.3 Micro syringe: 10μL. C.2.1.4 Ground-mouth test tube. C.2.1.5 Ground-mouth triangular flask. C.2.1.6 Balance: division value is 0.1mg. C.2.1.7 Dropper with rubber head. C.2.2 Reagents C.2.2.1 Internal standard substance: dibutyl phthalate, free of interfering impurities. C.2.2.2 Solvents: acetone, methanol (analytical reagent). C.2.2.3 Standard samples: allethrin, propargyrin, etc. C.2.3 Gas chromatography conditions C.2.3.1 Temperature C.2.3.1.1 Column temperature: 220°C. C.2.3.1.2 Gasification temperature: 250°C. C.2.3.1.3 Detector temperature: 250°C. C.2.3.2 Carrier gas: nitrogen. The above operating conditions are typical operating parameters. According to the characteristics of different instruments, the given operating conditions can be adjusted appropriately in order to obtain the best results. C.3 Preparation of standard solution In a ground-mouth test tube, accurately weigh 0.03g~0.04g (to the nearest of 0.0002g) of standard sample equivalent to the sample to be tested. Then weigh 0.015g~0.025g (to the nearest of 0.0002g) of dibutyl phthalate. Add methanol- acetone mixed solution. After fully dissolved, stopper and shake well, put in the refrigerator for use. C.4 Preparation of sample solution In a ground-mouth test tube, accurately weigh 1g~4g (to the nearest of 0.0002g, the ingredient to be tested is estimated about 0.03g~0.04g) of electrothermal mosquito liquid incense to be analyzed. Then weigh 0.015g~0.025g (to the nearest of 0.0002g) of dibutyl phthalate. Stopper and shake well, to be analyzed. C.5 Determination Under chromatographic conditions in C.2.3, after the instrument is stable, use a micro syringe to continuously inject standard sample solution until the peak area ratio of two adjacent needles and internal standard changes less than 1.5%. Conduct sample injection analysis in the order of standard sample solution, sample solution, sample solution, and standard sample solution. C.6 Calculation Respectively average the ratio of the peak area of the sample peak to the internal standard in the measured sample solution and the area ratio of the peak of the two internal standards to the peak of the standard sample. According to formula (C.1) and formula (C.2), calculate the mass fraction of the active ingredient to be measured, Mx. Correction factor: D.2.3 Gas chromatography conditions D.2.3.1 Temperature: the initial temperature of the column temperature is 220°C, the retention time is 13min; the termination temperature is 260°C, the retention time is 20 min; the heating rate is 20°C/min. Gasification temperature: 270°C. Detector temperature: 270°C. D.2.3.2 Carrier gas: nitrogen. The above operating conditions are typical operating parameters. According to the characteristics of different instruments, the given operating conditions can be adjusted appropriately in order to obtain the best results. D.3 Preparation of internal standard solution In a 100mL volumetric flask, weigh 0.3g~0.5g (to the nearest of 0.0002g) of corresponding internal standard substance. Use acetone or absolute ethanol to dissolve and set volume to scale. Shake well for use. D.4 Preparation of standard solution In a 50mL volumetric flask, accurately weigh various standard samples of an amount equivalent to the sample to be tested, m1 (to the nearest of 0.0002g). Add 5mL of internal standard solution. Set volume after complete dilution. Stopper and shake well. Put in the refrigerator to use. Method One: D.5 Preparation of sample solution In a clean 50mL volumetric flask, add 10mL of acetone or absolute ethanol. Shake the entire bottle of aerosol. Pre-spray several times. Use a sprinkler with a catheter (the end of the catheter is immersed in acetone or absolute ethanol) and slowly spray about 10g of the drug solution (the mass m2 is obtained by the weight reduction method, to the nearest of 0.001g). It can be placed in a 55°C water bath. After slowly removing the propellant (until there are no obvious bubbles), after adding 5mL of internal standard solution, use acetone or absolute ethanol to set volume to the scale. Shake well for use. D.6 Determination Under chromatographic conditions in D.2.3, after the instrument is stable, use a micro syringe to continuously inject standard sample solution until the peak area ratio of two adjacent needles and internal standard changes less than D.8 Preparation of standard solution In a ground-mouth test tube, accurately weigh various standard samples of an amount equivalent to the sample to be tested (to the nearest of 0.0002g). Then weigh 0.015g~0.025g (to the nearest of 0.0002g) of dipentyl phthalate. Add 5mL of acetone solution. After complete dilution, stopper and shake well. Put in the refrigerator to use. D.9 Sample pre-processing Take a can of aerosol sample. Place it in a low temperature box at about -15°C for 4h and take it out. Open a small hole with a diameter of about 0.2mm at the top of the tank. Place in 46°C water bath for 1h. Let the propellant slowly evaporate. Enlarge the hole. Pour out the liquid. D.10 Preparation of sample solution In a ground-mouth test tube, accurately weigh 10g of aerosol feed (to the nearest of 0.0002g, depending on the amount of substance to be tested). Then weigh 0.015g~0.025g of dipentyl phthalate. Stopper and shake well, to be analyzed. D.11 Determination Under chromatographic conditions in D.2.3, after the instrument is stable, use a micro syringe to continuously inject standard sample solution until the peak area ratio of two adjacent needles and internal standard changes less than 1.5%. Conduct sample injection analysis in the order of standard sample solution, sample solution, sample solution, and standard sample solution. D.12 Calculation Respectively average the ratio of the peak area of the sample peak to the internal standard in the measured sample solution and the area ratio of the peak of the two internal standards to the peak of the standard sample. According to formula (D.3), formula (D.4) and formula (D.5), calculate the mass fraction of the component to be tested, Mx. Correction factor: Mass fraction of ingredient to be tested: cstandard ......

BASIC DATA
Standard ID GB 24330-2020 (GB24330-2020)
Description (Translated English) General security technical specification for domestic sanitary insecticide
Sector / Industry National Standard
Classification of Chinese Standard G25
Classification of International Standard 65.100.10
Word Count Estimation 27,259
Date of Issue 2020-12-24
Date of Implementation 2022-01-01
Older Standard (superseded by this standard) GB 24330-2009
Quoted Standard GB/T 13917.1; GB/T 13917.2; GB/T 13917.3; GB/T 13917.4; GB/T 13917.5; GB/T 13917.6; GB/T 13917.7; GB/T 13917.8; GB/T 13917.9; GB/T 28015; NY/T 1151.1-2015; QB/T 4147; QB/T 4148; QB/T 4149; QB/T 4150
Drafting Organization Zhongshan Lanju Daily Chemical Industry Co., Ltd.
Administrative Organization Ministry of Industry and Information Technology
Regulation (derived from) National Standard Announcement No. 31 of 2020
Proposing organization Ministry of Industry and Information Technology of the People's Republic of China
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration
Summary This standard specifies general safety requirements and test methods for household hygiene and insecticide products related to personal health and environmental protection. This standard applies to sanitary insecticides used for household control of mosquitoes, flies, cockroaches and other pests.

BASIC DATA
Standard ID GB 24330-2009 (GB24330-2009)
Description (Translated English) General security technical specification for domestic sanitary insecticide
Sector / Industry National Standard
Classification of Chinese Standard G25
Classification of International Standard 65.100.10
Word Count Estimation 20,286
Date of Issue 2009-09-30
Date of Implementation 2010-05-01
Quoted Standard GB 13917.1; GB 13917.2; GB 13917.3; GB 13917.4; GB 13917.5; GB 13917.6; GB 13917.7; GB/T 17322.1; GB/T 17322.2; GB/T 17322.3; GB/T 17322.4; GB/T 17322.5; GB/T 17322.6; GB/T 17322.7; GB/T 17322.8; GB/T 17322.9; GB/T 17322.10; GB/T 17322.11; quality Supervision, Inspection and Quarantine Order No. 75 " prepackaged goods metrological supervision and management"; Ministry of Agriculture Dement [ 2007 ] 10 orders " pesticide registration data requirements."
Drafting Organization Zhongshan Daily Chemical Industry Co., Ltd. Lanju
Administrative Organization National Domestic sanitary insecticide Standardization Technical Committee
Regulation (derived from) Announcement of Newly Approved National Standards No. 10 of 2009 (No. 150 overall)
Proposing organization China Light Industry Federation
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Chinese standard specifies the household sanitary insecticide products general terms and definitions, requirements, test methods. This standard applies to household sanitary insecticide products related to health, environmental safety General requirements.