HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (6 Oct 2024)

GB 23255-2019 related PDF English

GB 23255-2019 (GB23255-2019) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB 23255-2019English110 Add to Cart 0-9 seconds. Auto delivery. Photometric Characteristics of Daytime Running Lamps for Power Driven Vehicles GB 23255-2019 Valid GB 23255-2019
GB 23255-2009English90 Add to Cart 0-9 seconds. Auto delivery. Photometric characteristics of daytime running lamps for motor vehicles GB 23255-2009 Obsolete GB 23255-2009
Buy with any currencies (Euro, JPY, KRW...): GB 23255-2019    Preview this PDF: GB 23255-2019



GB 23255-2019: PDF in English
GB 23255-2019 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 43.040.20 T 38 Replacing GB 23255-2009 Photometric Characteristics of Daytime Running Lamps for Power Driven Vehicles ISSUED ON: APRIL 4, 2019 IMPLEMENTED ON: JANUARY 1, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative References ... 4  3 Terms and Definitions ... 4  4 Different Types of Daytime Running Lamps ... 4  5 Requirements ... 5  6 Test Methods ... 8  7 Inspection Rules ... 10  8 Requirements of Transition Period ... 11  Photometric Characteristics of Daytime Running Lamps for Power Driven Vehicles 1 Scope This Standard stipulates the photometric characteristics, test methods and inspection rules of daytime running lamps for power driven vehicles. This Standard is applicable to various types of daytime running lamps used by Category-L, Category-M and Category-N power driven vehicles. 2 Normative References The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this Standard. GB 4599 Motor Vehicle Headlamps Equipped with Filament Lamps GB 4785 Prescription for Installation of the External Lighting and Light-signaling Devices for Motor Vehicles and Their Trailers GB/T 15766.1 Lamps for Road Vehicles – Dimensional, Electrical and Luminous Requirements ECE R37 Uniform Provisions Concerning the Approval of Filament Lamps for Use in Approved Lamp Units on Power-driven Vehicles and of Their Trailers ECE R128 Uniform Provisions Concerning the Approval of Light Emitting Diode (LED) Light Sources for Use in Approved Lamp Units on Power-driven Vehicles and Their Trailers 3 Terms and Definitions Terms and definitions defined in GB 4599, GB 4785 and GB/T 15766.1 are applicable to this document. 4 Different Types of Daytime Running Lamps Daytime running lamps including interlocking lamp system, have differences in the following main aspects: 6 Test Methods 6.1 Requirements of Darkroom, Device and Equipment Test darkroom, device and equipment shall comply with the stipulations in GB 4599. 6.2 Requirements of Visual Surface Visual surface boundary in the reference axis direction of daytime running lamps shall be determined. 6.3 Voltage Requirements in Photometric Test and Chromaticity Test 6.3.1 If electric light source controller is not used, colorless or colored standard light sources of categories stipulated by daytime running lamps shall be adopted. In addition, the following voltages shall be provided: a) In terms of filament light bulbs, they shall be measured under the stipulated reference luminous flux; b) In terms of 6.75 V, 13.5 V or 28.0 V LED light sources, luminous flux shall be calibrated. Calibration coefficient shall be the ratio of the target luminous flux and the average luminous flux of input voltage. 6.3.2 In terms of systems which use electric light source controller, and act as a part of daytime running lamps, the voltage of the supply lamp input terminal shall respectively be 6.75 V, 13.5 V or 28.0 V. 6.3.3 In terms of systems which use electric light source controller, but do not belong to a constituent component of daytime running lamps, the voltage released by the manufacturer shall be input to the input terminal. Laboratories may demand electric light source controller, which provides voltage to light sources, from the manufacturer. The voltage input to daytime running lamps shall be indicated in the technical instruction in 7.1.1 b). 6.3.4 In terms of daytime running lamps with irreplaceable light sources (filament light bulbs and others), the test voltage shall comply with the requirements in 6.3.2. 6.4 Requirements of Preparation before Photometric Test Before photometric test, light sources shall be lightened up in accordance with the voltage during the test, so that the optical performance could approach stability. 6.5 Requirements of Photometric Measurement of Daytime Running Lamps with Different Light Sources 6.5.1 In terms of daytime running lamps with irreplaceable light sources (filament light 6.8.2.1 In terms of daytime running lamps with replaceable light sources, they shall comply with the following requirements: a) If the light sources have stipulated maximum and minimum power, comply with the voltage that reaches the maximum and the minimum median power in the test. If they are applicable to multiple nominal voltages, choose the voltage which has the maximum power for the test; b) If light source’s maximum power is merely stipulated, voltage shall be adjusted to 90% of the maximum power. If they are applicable to multiple nominal voltages, choose the voltage which has the maximum power for the test. 6.8.2.2 In terms of daytime running lamps with irreplaceable light sources (filament light bulbs and others), the test voltage shall comply with the requirements in 6.3.2. 7 Inspection Rules 7.1 Requirements of Type Inspection 7.1.1 The manufacturer shall provide the following documents: a) A detailed description of device, vehicle and reference axis on the reference plane of the ground, which is installed through the method of different inclinations on the vehicle, or the installation on vehicle through the method of rotation around the reference axis. All the interlocking lamps in the interlocking lamp system shall also be submitted. b) Display sufficient details, so as to identify the drawings of this type of daytime running lamps. The drawings shall indicate the geometric position of the installation of daytime running lamps on vehicle, and the observation axis (horizontal angle H = 0; vertical angle V = 0), which works as reference axis in the test, and the visual surface, which works as reference center in the above-mentioned test. c) A concise technical instruction. Other than daytime running lamps with irreplaceable light sources, it shall also indicate: 1) Use the stipulated types of filament light bulbs; 2) Use the stipulated types of LED light sources; 3) In the usage of light source module, its type and parameters shall be provided, which may include the specifications, dimensions, optical parameters and target luminous flux of LED module; 4) Use the installation indication signals. ......

BASIC DATA
Standard ID GB 23255-2019 (GB23255-2019)
Description (Translated English) Photometric Characteristics of Daytime Running Lamps for Power Driven Vehicles
Sector / Industry National Standard
Classification of Chinese Standard T38
Classification of International Standard 43.040.20
Word Count Estimation 8,822
Date of Issue 2019-04-04
Date of Implementation 2020-01-01
Drafting Organization Shanghai Motor Vehicle Testing and Certification Technology Research Center Co., Ltd., Changchun Hella Auto Lamp Co., Ltd., Shanghai Automotive Group Co., Ltd. Technology Center
Administrative Organization Ministry of Industry and Information Technology of the People's Republic of China
Proposing organization Ministry of Industry and Information Technology of the People's Republic of China
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration