Safety regulations for the protection of dust explosion for grain processing, storage and transportation system
|
GB 17440-2008
| Valid |
GB 17440-2008
|
GB 17440-1998 | English | 439 |
Add to Cart
|
4 days
|
Safety regulations for the protection of dust explosion for grain processing, storage and transportation system
|
GB 17440-1998
| Obsolete |
GB 17440-1998
|
Buy with any currencies (Euro, JPY, KRW...): GB 17440-2008 Preview this PDF: GB 17440-2008
GB 17440-2008
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 13.230
C 67
Replacing GB 17440-1998
Safety regulations for the protection of dust explosion for
grain processing, storage and transportation system
ISSUED ON. DECEMBER 11, 2008
IMPLEMENTED ON. OCTOBER 01, 2009
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative references ... 5
3 Terms and definitions ... 6
4 Zoning and range of grain dust explosion hazardous areas ... 7
5 Process device ... 9
6 Electrical ... 12
7 Building and structure ... 16
8 Dust control ... 17
9 Dust cleaning ... 20
10 Pneumatic conveying ... 21
11 Safety precautions for radiation device use ... 21
12 Safety precautions for use in ultrasonic device ... 22
13 Operational safety management ... 22
Appendix A (Informative) List of monitoring device setting for the main
machinery device operation status in dust explosion hazardous area ... 25
Appendix B (Informative) Grain dust characteristics table ... 26
Appendix C (Informative) Descriptions of standard clauses ... 27
Foreword
All the technical contents of this standard are mandatory.
This standard is the revision of GB 17440-1998 “Safety regulations for the
protection of dust explosion for grain processing, storage and transportation
system” based on the dust explosion-proof practical experience of China's grain
storage and transportation, processing system in recent years.
This standard replaces GB 17440-1998 “Safety regulations for the protection of
dust explosion for grain processing, storage and transportation system”.
As compared with GB 17440-1998, main changes of this standard are as
follows.
- In the Scope, ADD that “it does not apply to grain drying device”;
- ADD the terms of dust release source and explosive dust atmosphere;
- CHANGE the dust explosion hazardous zone classification into zone 20,
21 and 22;
- ADD the dust explosion hazardous zoning of the relevant places of the
plant oil factory;
- The choice of electrical device is divided into type A device and type B
device;
- MODIFY the requirements for building (structure) in accordance with the
relevant fire protection code;
- CHANGE the contents related to ventilation and dedusting into the “Dust
control” chapter;
- ADD the “Pneumatic conveying” chapter;
- ADD the requirements of radiation device and ultrasonic device;
- CHANGE the original chapter “Management” into “Operational safety
management”;
- CHANGE the original Appendix A “Grain dust characteristics table” into the
Appendix B “Grain dust characteristics table”;
Safety regulations for the protection of dust explosion for
grain processing, storage and transportation system
1 Scope
This standard specifies the basic requirements for the protection of dust
explosion for grain processing, storage and transportation system.
This standard applies to the whole process of design, construction, production
and management of newly built, extended, and reconstructed projects which
may have grain dust explosion hazardous places in the grain processing,
storage and transportation process.
This standard does not apply to grease leaching plant and grain drying device.
2 Normative references
The provisions in following documents become the provisions of this Standard
through reference in this Standard. For the dated references, the subsequent
amendments (excluding corrections) or revisions do not apply to this Standard;
however, parties who reach an agreement based on this Standard are
encouraged to study if the latest versions of these documents are applicable.
For undated references, the latest edition of the referenced document applies.
GB 12476.1 Electrical apparatus for use in the presence of combustible dust
- Part 1-1. Electrical apparatus protected by enclosures and surface
temperature limitation - Specification for electrical apparatus (GB 12476.1-
2000, idt IEC 61241-11.1999)
GB 12476.2-2006 Electrical apparatus for use in the presence of
combustible dust - Part 1-2. Electrical apparatus protected by enclosures
and surface temperature limitation - Selection, installation and maintenance
of electrical apparatus (IEC 61241-1.1999, IDT)
GB/T 15604 Terminology for dust explosion prevention
GB 50016 Code of design on building fire protection and prevention
GB 50057 Design code for protection of structures against lightning
5 Process device
5.1 Process design
5.1.1 Grain processing, storage and transportation system design shall follow
the principle of overall fortification, AND be in strict compliance with the
technical requirements for dust explosion prevention.
5.1.2 The design documents shall clearly state the zoning of the grain dust
explosion hazardous zone in the design, AND propose a clear and specific
measures and methods for dust explosion prevention on the building structure,
process selection, device type selection and layout, dust control, electrical and
management, etc.
5.1.3 It is preferable for the device prone to dust explosion to be arranged
outdoors; however, if it is arranged indoor, it is preferable for it to be at a higher
position in the building AND close to the exterior wall.
5.1.4 Process piping and dedusting network shall not be through unrelated
buildings. There shall be no unrelated pipes passing through dangerous areas.
5.1.5 It is not preferable for the process pipeline and dedusting network to be
laid in multiple layers in the same rack with the heat pipe. When they are laid in
multiple layers in the same rack with utilities pipelines, it is preferable to place
the pipeline having a medium temperature higher above normal temperature at
the upper layer, AND to take thermal insulation measures.
5.2 Machinery and device
5.2.1 General requirements
5.2.1.1 For the stationary machinery and device used in hazardous areas of
grain dust explosion, it is preferable to take explosion-proof measures. When
using the explosion pressure venting method, it is preferable for the venting port
to be lead outdoor to a safe direction through the pipeline.
5.2.1.2 The observation window (door), removable cover (door), and ventilation
holes can be regarded as explosion pressure venting port.
5.2.1.3 The highest level of material in the device or silo shall not exceed the
lower edge of the venting port. The venting ports shall be located so that they
will not make the surroundings be exposed to flames and gas hazards.
Explosion pressure venting process shall not endanger personnel or limit the
operation of safety-related device.
5.2.2.2 Screw conveyor
- Spiral shall be flexible, its clearance with the housing shall comply with
requirements, AND it shall be free from scratching or jamming.
5.2.2.3 Buried scraper conveyor
- Scraper chain shall correctly engage when running into the head pulley,
AND it shall be free from chain jamming or jumping.
5.2.2.4 Roller belt conveyor and air cushion belt conveyor
- Conveyor belt shall run smoothly, the deviation is in the specified range,
AND the belt shall not direct scratch the bracket and cover.
5.2.3 Measuring device
- It shall provide the air balancing device ensuring the scale inside pressure
balance and avoiding dust fly in between the discontinuous weighing
scale’s upper hopper and lower hopper, AND it is preferable to connect it to
the dust control system.
5.2.4 Cleaning device
- Mesh shall be smooth, there shall be no congestion.
5.2.5 Dedusting device
- The type and structure of dust collector shall meet the dust control
requirements;
- It is preferable for the dust collector to take the explosion pressure venting
method, with sufficient pressure venting area;
- Explosion-proof membrane shall ensure the sealing, AND it shall be able to
withstand the maximum suction pressure produced by the fan at different
conditions.
5.2.6 Processing device
5.2.6.1 When the grain enters high-speed rotating device for grinding, crushing,
cutting and shelling, etc., the device for magnetic separation to remove metal
impurities and the cleaning device to remove inorganic impurities and other
impurities shall be provided before these devices.
5.2.6.2 It shall close in time the non-operating circuit (including the branch), so
as to prevent the accident from spreading in case of fault.
6.2.8 It shall use the dust explosion-proof type lighting device in the zone 20,
21 and 22. AND the net distance between the lighting fixture and the grain shall
not be less than 500 mm.
6.2.9 It is not preferable to use the mobile electrical device in zone 20, 21 and
22. If it is necessary to use mobile electrical device, it shall use the YC or YCW
rubber cable.
6.3 Cabling
6.3.1 Cables (wires) that are not related to dangerous area shall, as far as
possible, not pass through dangerous areas. If unavoidable, they shall comply
with the provisions of electrical wiring in dangerous dust explosion areas.
6.3.2 The types of cabling used in zone 20, 21 and 22 may be.
- The cable shall be laid in a seamless or seam welded steel pipe with a
threaded connection;
- Cable itself has sufficient mechanical strength, AND is able to prevent
mechanical damage and combustible dust intrusion.
6.3.3 Cable systems and accessories shall be installed at locations, as far as
possible, free from mechanical damage, corrosion, chemical effects and
thermal effects. If unavoidable, it shall be installed in a conduit or select the
appropriate cable.
6.3.4 If the cable or conduit system is subject to vibration, it shall be designed
into a structure which can...
......
Standard ID | GB 17440-2008 (GB17440-2008) | Description (Translated English) | Safety regulations for the protection of dust expolsion for grain processing, storage and transportation system | Sector / Industry | National Standard | Classification of Chinese Standard | C67 | Classification of International Standard | 13.230 | Word Count Estimation | 24,218 | Date of Issue | 2008-12-11 | Date of Implementation | 2009-10-01 | Older Standard (superseded by this standard) | GB 17440-1998 | Quoted Standard | GB 12476.1; GB 12476.2-2006; GB/T 15604; GB 50016; GB 50057 | Drafting Organization | State Grain Reserve, Zhengzhou Scientific Research and Design Institute | Administrative Organization | National Safety Standardization Technical Committee Technical Committee dust explosion | Regulation (derived from) | Announcement of Newly Approved National Standards No. 19 of 2008 (No. 132 overall) | Proposing organization | State Administration of Work Safety | Issuing agency(ies) | Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China | Summary | This Chinese standard specifies the food processing, storage and transportation system dust explosion basic requirements. This standard applies to food handling, transportation, storage and processing of grain dust or may occur explosive dangerous places new construction, expansion, renovation project design, construction, production and management of the entire process. This standard does not apply to oil extraction plant and grain drying equipment. | Standard ID | GB 17440-1998 (GB17440-1998) | Description (Translated English) | Safety regulations for the protection of dust explosion for grain processing, storage and transportation system | Sector / Industry | National Standard | Classification of Chinese Standard | C67 | Classification of International Standard | 13.23 | Word Count Estimation | 11,141 | Date of Issue | 1998/7/28 | Date of Implementation | 1999/6/1 | Quoted Standard | GB 50057-1994; GB 50058-1992; SBJ 03-1989; SBJ 06-1993 | Regulation (derived from) | Announcement of Newly Approved National Standards No. 19 of 2008 (No. 132 overall) | Proposing organization | Ministry of Internal Trade and Ministry of Labor | Issuing agency(ies) | State Quality and Technical Supervision | Standard ID | () | Description (Translated English) | (Technical specifications for ceramic capacitive sensor type partial discharge monitoring devices of 35kV and below) | Sector / Industry | Chinese Industry Standard | Date of Issue | 2023-10-11 | Date of Implementation | 2024-04-11 | Issuing agency(ies) | National Energy Board |
|