HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (6 Oct 2024)

GB 14536.11-2008 related PDF English

GB 14536.11-2008 (GB14536.11-2008) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB 14536.11-2008English85 Add to Cart 0-9 seconds. Auto delivery. [GB/T 14536.11-2008] Automatic electrical controls for household and similar use -- Particular requirements for motor-starting relays GB 14536.11-2008 Valid GB 14536.11-2008
GB 14536.11-1996English279 Add to Cart 3 days Automatic electrical controls for household and similar use. Particular requirements for electricaly perated modor starting relays GB 14536.11-1996 Obsolete GB 14536.11-1996
Buy with any currencies (Euro, JPY, KRW...): GB 14536.11-2008    Preview this PDF: GB 14536.11-2008



GB 14536.11-2008: PDF in English
GB 14536.11-2008 Automatic electrical controls for household and similar use.Particular requirements for motor-starting relays ICS 29.130.20 K32 National Standards of People's Republic of China GB 14536.11-2008/IEC 60730-2-10.2006 Replacing GB 14536.11-1996 Household and similar electrical automatic controller Particular requirements for motor starting relays (IEC 60730-2-10.2006, IDT) Posted 2008-12-30 2010-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of Contents Introduction Ⅲ IEC Introduction Ⅴ 1 Scope and normative references 1 2 Definitions 1 3 General requirements 1 4 General notes 2 Rating 2 5 6 Category 2 7 Profile 2 8 Protection against electric shock 2 9 ground protection measures 2 10 Terminals and terminations 2 11 structural requirements 3 12 moisture and dust 3 13 Electric strength and insulation resistance 3 14 heat 3 15 Manufacturing deviation and drift 3 3 16 Environmental Stress Durability 17 3 The mechanical strength of 18 3 19 Threaded parts and connections 3 20 creepage distances, clearances and distances through solid insulation through 3 21 heat, fire and resistance to tracking 3 Corrosion resistance of 22 3 23 Electromagnetic compatibility (EMC) emission requirements --- 4 24 assembly 4 25 Normal operation 4 26 Electromagnetic compatibility (EMC) requirements --- immunity 4 27 non-normal operation 4 28 Guidelines for the use of electronic disconnect 4 Figure 5 Appendix 6 Annex C (normative) mercury switch test cotton 6 Appendix E (normative) leakage current measurement circuit 6 Annex H (normative) requirements for electronic controllers 7 GB 14536.11-2008/IEC 60730-2-10.2006 Foreword All technical content in this section is mandatory. GB 14536 "Household and similar electrical automatic controller" is divided into two parts. --- Part 1. General requirements; --- Part 2. Particular requirements. Special requirements and consists of the following components. --- GB 14536.3 - Particular requirements for thermal motor protectors (IEC 60730-2-2, IDT); --- Particular requirements GB 14536.4 tubular fluorescent lamp ballasts for thermal protectors (IEC 60730-2-3, IDT); --- GB 14536.5 sealed and semi-hermetic motor - compressor motor thermal protection Particular requirements (IEC 60730-2-4, IDT); --- Particular requirements GB 14536.6 automatic electrical burner control systems (IEC 60730-2-5, IDT); --- GB 14536.7 pressure sensitive electrical controls - Particular requirements (idt IEC 60730-2-6); --- GB 14536.8 Particular requirements for timers and time switches (idt IEC 60730-2-7); --- GB 14536.9 Particular requirements for electrically operated water valves (including mechanical requirements) (IEC 60730-2-8, IDT); --- GB 14536.10 - Particular requirements for temperature sensing controls (IEC 60730-2-9, IDT); --- GB 14536.11 Particular requirements for motor starting relays (IEC 60730-2-10, IDT) used; --- GB 14536.12 Particular requirements for energy regulators (idt IEC 60730-2-11); --- GB 14536.13 Particular requirements for electrically operated door locks (IEC 60730-2-12, IDT); --- GB 14536.15 Particular requirements for humidity sensing controls (IEC 60730-2-13, IDT); --- GB 14536.16 Particular requirements for electric actuators (idt IEC 60730-2-14); --- GB 14536.17 special requirements of the float or electrode-sensitive automatic electrical water level sensing controller used in the boiler appliance (IEC 60730-2-15, IDT); --- GB 14536.18 - Particular requirements for household and similar use of the float type level controllers (IEC 60730-2-16, IDT); --- GB 14536.19 Particular requirements for electrically operated gas valves, including mechanical requirements (IEC 60730-2-17, IDT); --- GB 14536.20 Particular requirements for water and air flow sensing controls, including mechanical requirements (IEC 60730-2-18, IDT); --- GB 14536.21 Particular requirements for electrically operated oil valves, including mechanical requirements (IEC 60730-2-19, IDT); This section identical with IEC 60730-2-10.2006 "Household and similar electrical controls - Part 2. motor starting Particular requirements for the relay. " Part of this structure with IEC 60730-2-10.2006 same. In this section, there is a corresponding national standards, national standards incorporated by reference Quasi; no national standards, IEC standards are incorporated by reference outlined. For ease of use, this section made the following editorial changes. a) "This standard" be replaced by "this section"; b) use a decimal point instead of a decimal comma ",". ","; c) increase the national standard foreword. This part of GB 14536.1-2008 "Household and similar electrical controls - Part 1. General requirements" in conjunction. This Part replaces GB 14536.11-1996 "Household and similar electrical controls for motor starting relays to begging". Compared with GB 14536.11-1996 part of the main changes are as follows. GB 14536.11-2008/IEC 60730-2-10.2006 --- Several sections according to the change of the name of GB 14536.1 made the appropriate changes; --- Chapter 1 apply to rated voltage range according to the general asked to do modified accordingly; --- Chapter 27 of the test contents are different; Appendix H --- changing requirements. This part of the Annex C, Annex E and Annex H normative appendix. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee household automatic control (SAC/TC212) centralized. This section is drafted. Guangzhou CVC Testing Institute, Guangzhou Electric Apparatus Research Institute, Wanbao Refrigeration Group Guangzhou Electrical Appliance Co., Division Hangzhou Star Shuai Seoul Electric Co., Ltd. Foshan Tongbao, Lanxi City, the Electric Appliance Co., Ltd. Zhejiang Yan thermostat limited The company, Shunde District of Foshan City, Yung your measurement Electric Co. Ltd., China Household Electrical Appliances Research Institute. Drafters of this section. Core hole Xun, Zhu Liping, Huang Kaiyun, Huang Zhi Hang, Lu Wencheng, wheat harvest, high Yonghua, Chen Yonglong, Hedun Qi, Gu Yulin. This part of the standard replaces the previous editions are. --- GB 14536.11-1996. GB 14536.11-2008/IEC 60730-2-10.2006 IEC Foreword 1) IEC (International Electrotechnical Commission) is a worldwide standardization group composed of national electrotechnical committees (IEC National Committees) Organizations. The object of IEC is to promote international cooperation on issues related to the standardization of the electrical and electronic fields. For this purpose IEC addition to other activities, but also publishes International Standards, technical specifications, technical reports, public specification (PAS, Publicly AvailableSpecifications) and guidelines (henceforth referred to IEC publication). Their preparation is entrusted to technical Commission to complete. As a member of IEC National Committees, as long as the interest of the standard to be developed, may participate Its formulation. Liaising with the IEC 's international, official or unofficial organizations are also involved in the development of standards. IEC and the World Organization for Standardization (ISO ) in accordance with the conditions specified in the agreement, close cooperation. 2) since each technical committee has representatives from the National Commission on the relevant issues of interest, so the IEC on technical Issue formal decisions or agreements on the maximum expression of the international consensus on the relevant issues. 3) IEC Publications have the form of recommendations for international use, and accepted by the National Committees in that sense. Despite being made There are possible effort to ensure that the technical content of IEC publications is correct, IEC these publications can not be used Way or misinterpretation of any user and responsibility. 4) In order to promote international unification, IEC National Committees in charge of the IEC international standards transparently converted to the maximum extent possible National or regional standards. Between the IEC Standard and the corresponding national or regional standard if there is any difference, it should be converted into the standard After clearly illustrates. 5) IEC did not develop any signs of approval procedure, when a device if it complies with the IEC declared a publication, which is not IEC Accountable. 6) All users should make sure you have the latest version of this publication. 7) IEC or its leaders, employees, servants or agents, including independent experts and IEC technical committees, national committee Members will, for the use of any person or the trust of the IEC standards or other IEC publication caused casualties, property damage Loss or other damage to the natural environment (whether such losses are direct or indirect) does not bear any responsibility for the phase Should produce costs and expenses (including legal fees) is not liable. 8) To take note of the standard referenced standards. Use the referenced standard is correct application of this standard essential. 9) It is noteworthy that this International Standard may involve some parts of the patent. IEC for the identification of some or all of this A Class of the patent will be irresponsible. IEC 60730-2-11 by the IEC Technical Committee TC72. home automation controller developed. This second edition cancels and replaces the first edition in 1994 and its amendments 1 and 2001 amendments enacted in 1991 2. The second edition Constitute a technical revision and update of the standard to meet the current practice while also parallel with the use of the standard. Standard text based on the following documents. FDIS Report on voting 72/711/FDIS 72/724/RVD For more information on this standard a vote, the vote on the report, see the table below. Drafting of the publication to comply with ISO /IEC Guide. Part II. The second part of the book used in conjunction with IEC 60730-1. This requirement was established in 1999, the third edition of IEC 60730-1 and 2003 Amendment 1 basis. IEC 60730-1 should be considered in subsequent versions or revisions. This part supplements or modifies the corresponding provisions in IEC 60730-1 so as to be converted to the corresponding IEC standards. motor starting relay Particular requirements for electrical appliances. GB 14536.11-2008/IEC 60730-2-10.2006 When appearing in this part of the "addition", "modification" or "replacement", the general requirements of the relevant requirements, test description or explanatory content should Be amended accordingly. When no change, this section will indicate the appropriate sections or provisions apply. In the development of a full international standard, we must consider the different requirements of the actual situation of the various regions of the world is formed, and should be recognized Differences in each country's electrical systems and wiring rules. Use the following printed in this section. --- Body requirements. roman; --- Test specifications. italic; --- Note matters. small roman type. For the first part of sub-clause is part of the newly added, comments, or items shown are numbered starting from 101, and the newly added Appendix Places letters AA, BB starts. All belong to the IEC 60730 series, attributable to the standard, "household and similar use automatic controller" category list, you can IEC Get on the website. The Committee decided that the contents of this publication in the IEC 's website http. // webstore. iec. On ch marked, and specific publications related Remain unchanged before the next revision date. And to this date, the publication will be. ● reconfirmed; ● Cancel; ● The revised version of the substitution; or ● Amendment. GB 14536.11-2008/IEC 60730-2-10.2006 Household and similar electrical automatic controller Particular requirements for motor starting relays 1 Scope and normative references GB 14536.1 of the chapter is applicable except as follows. 1.1 Replacement. This section applies to household and similar equipment with automatic control of single-phase motor starting control winding. This section applies to use NTC or PTC thermistor motor starting relays, the corresponding requirements of Appendix J. 1.1.1 This section applies to the inherent safety Automatic electrical controls for safety equipment and related operating values, operating time and operating procedures Sequence, starting relays and test applies to household or similar device or equipment used in conjunction with an electric motor. Not as a general household, but for the public, such as equipment shops, light industry and farm use by non-professionals, the use of Motor starting relays are also included within the scope of this. This part is not designed solely for the purpose of industrial motors use starting relays. Note. "device" in this section use the term with "utensils and equipment." The term "start relay" means "motor starting relays." 1.1.2 This section applies to an electronic device equipped with the starter relay, also apply to the use of a thermistor element, from the element and the magnetic elements Relay. 1.1.3 This section does not apply to general purpose relays or contactors within the GB 14048 series range, the motor starter. This section Does not apply to electrical and mechanical timers mechanically operated starter. 1.1.4 This section applies to those in the manual control or mechanically and electrically starter relay combination. Manual switch request does not constitute a part of the starter is contained in the GB 15092.1. 1.2 Replacement. This section applies to the rated voltage not exceeding 690V, rated current not exceeding 63A of the starter relay. 1.3 Replacement. This section considered response depends on the starter relay in the device mounting method of automatic operation. If the response to make to protect Wearer and the surrounding environment meaningful response by the manufacturer or by the determination of the appropriate equipment standard values apply. 1.4 Replacement. This section also applies to the starter relay with electronic devices, the corresponding requirements of Annex H. 2 Definitions GB 14536.1 of the chapter is applicable except as follows. 2.2 is defined by use classification controller Addition of provisions. 2.2.101 Booking is integral to the appliance or load, for controlling the primary winding of the motor and the auxiliary circuit is connected to the start winding up To start for household and similar appliances used in single-phase motor controller electrically operated. Note. In general, the motor starting relays will provide Type 1 action. 3 General requirements GB 14536.1 of this chapter shall apply. GB 14536.11-2008/IEC 60730-2-10.2006 General Description 4 Test GB 14536.1 of this chapter shall apply. 5 RATINGS GB 14536.1 of this chapter shall apply. Category 6 GB 14536.1 of the chapter is applicable except as follows. 6.3 By Application Addition of provisions. 6.3.101 --- motor starting relays. 6.3.101.1 --- voltage sensitive. 6.3.101.2 --- current sensitive. 6.3.101.3 --- PTC. 6.3.101.4 --- Thermal. 6.13 The press resistant insulating material tracking index (PTI) value classification 6.13.1 Not applicable. 6.15 Classification by structure instead. 6.15 Integral mount or formula 6.15.1 --- electrons. 6.15.2 --- electromagnetic. 6.15.3 --- PTC thermistor. 6.15.4 --- Thermal. NOTE. Although referred to in 6.15.2 to 6.15.4 relay the main structure does not belong to the electronic structure, but which may be equipped with internal electronic components. 7 Information GB 14536.1 of the chapter is applicable except as follows. Table 7.2 increase. Information chapter, strip method 101 motor stable running current 14.4 X 8 Protection against electric shock GB 14536.1 of this chapter shall apply. 9 ground protection measures GB 14536.1 of this chapter shall apply. 10 Terminals and terminations GB 14536.1 of this chapter shall apply. GB 14536.11-2008/IEC 60730-2-10.2006 11 structural requirements GB 14536.1 of this chapter shall apply. 12 moisture and dust GB 14536.1 of this chapter shall apply. 13 Electric strength and insulation resistance GB 14536.1 of this chapter shall apply. Fever 14 GB 14536.1 of the chapter is applicable except as follows. 14.4 Replacement. 1.06 times the motor is applied in Table 7.2 101 declared starter relay coil motor steady-state operating current. Should contact Not loaded. 14.4.3.1 Not applicable. 14.4.3.2 Not applicable. 15 Manufacturing deviation and drift GB 14536.1 of this chapter shall apply. 16 Environmental Stress GB 14536.1 of this chapter shall apply. 17 Durability GB 14536.1 of the chapter is applicable except as follows. 17.9 ~ 17.13 NA. 18 Mechanical strength GB 14536.1 of this chapter shall apply. 19 Threaded parts and connections GB 14536.1 of this chapter shall apply. 20 creepage distances, clearances and distances through solid insulation through GB 14536.1 of this chapter shall apply. 21 heat, fire and tracking resistance GB 14536.1 of this chapter shall apply. 22 corrosion resistance GB 14536.1 of this chapter shall apply. GB 14536.11-2008/IEC 60730-2-10.2006 23 Electromagnetic compatibility (EMC) emission requirements --- GB 14536.1 of this chapter shall apply. 24 components GB 14536.1 of this chapter shall apply. 25 normal operation GB 14536.1 of this chapter shall apply. 26 Electromagnetic compatibility (EMC) requirements --- immunity GB 14536.1 of this chapter shall apply. 27 non-normal operation GB 14536.1 of the chapter is applicable except as follows. increase. 27.2 Burning Test Modify interpretation section. Note. For motor starting relays, successful completion of the test Chapter 17 is considered to meet the terms. instead. 27.3 overvoltage and undervoltage test Not applicable. 28 Guidelines for the use of electronic disconnection GB 14536.1 of this chapter shall apply. GB 14536.11-2008/IEC 60730-2-10.2006 Fig GB 14536.1 FIG apply. GB 14536.11-2008/IEC 60730-2-10.2006 appendix GB 14536.1 Appendix, is applicable except as follows. Appendix C (Normative) Mercury switch test cotton Not applicable. Appendix E (Normative) Leakage current measurement circuit Not applicable. GB 14536.11-2008/IEC 60730-2-10.2006 Appendix H (Normative) Requirements for electronic controllers GB 14536.1 of the appendix, is applicable except as follows. H. 17 Durability GB 14536.1 of the chapter is applicable except as follows. H. 17.1.4.2 Thermal cycling test a) cycle instead. Test period 18d. H. 26 Electromagnetic compatibility (EMC) requirements --- immunity GB 14536.1 of the chapter is applicable except as follows. H. 26.2.1 Replacement. For motor starting relays, meets the requirements, by H. 26.8 and H. The test was 26.9. Note. The motor starting relays, H. 26.4 and H. 26.9 Other disturbances will not result in inherently dangerous. Changes inherent dangers and output from Other tests of this standard to evaluate. increase. H. 26.9.101 test program Controller 5 tests. H. Replace the first paragraph 26.13.2 an explanation. Note. The test allows the controller is no longer operational. Subject to the second option, the acceptability of the declared output must be in the final product Assessment to determine this output does not cause unsafe operation. GB 14536.11-2008/IEC 60730-2-10.2006 ......

BASIC DATA
Standard ID GB 14536.11-2008 (GB14536.11-2008)
Description (Translated English) [GB/T 14536.11-2008] Automatic electrical controls for household and similar use. Particular requirements for motor-starting relays
Sector / Industry National Standard
Classification of Chinese Standard K32
Classification of International Standard 29.130.20
Word Count Estimation 15,170
Date of Issue 2008-12-30
Date of Implementation 2010-02-01
Older Standard (superseded by this standard) GB 14536.11-1996
Quoted Standard GB 14536.1
Adopted Standard IEC 60730-2-10-2006, IDT
Drafting Organization Guangzhou Institute of CVC detection technology
Administrative Organization National Standardization Technical Committee of home automation controller
Regulation (derived from) Announcement of Newly Approved National Standards No. 26 of 2008 (total 139)
Proposing organization China Electrical Equipment Industry Association
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Chinese standard applies to equipment for household and similar use automatic control of single-phase motor start-winding controller. This standard applies to an NTC or PTC thermistors motor starting relays, the corresponding requirements in Appendix J. 1. 1. 1 this standard applies to the inherent safety Automatic electrical controls for safety -related operations and equipment value, the operating time and operating procedures, as well as for the home or similar device, or with the device used motor starting relays tests. Not intended for normal household, but are used in public places such as shops, light industry and farms by non-professionals use equipment, the use of motor starting relays are also included within the scope of this standard. This standard is not designed for industrial purposes for motor starting relays. Note: this standard uses the"device"encompasses"appliances and equipment. "Starter relay"means that"motor starting relays. "1. 1. 2 this standard applies to the starter relay is equipped with electronic devices, also apply to the use of a thermistor element, heating elements and magnetic components starter relay. 1. 1. 3 this standard does not apply to GB 14048 series within the scope of general purpose relays or contactors, motor starters. This standard does not apply to mechanical timers and mechanical operation of the electric starter. 1. 1. 4 this standard applies to those who are electrically or mechanically combined with the starter relay manual controller. Does not constitute a part of the starter of the manual switch in the request contained in GB15092. 1