GB 14536.11-2008 (GB14536.11-2008) & related versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | See Detail | Status | Similar PDF |
GB 14536.11-2008 | English | 85 |
Add to Cart
|
0-9 seconds. Auto delivery.
|
[GB/T 14536.11-2008] Automatic electrical controls for household and similar use -- Particular requirements for motor-starting relays
|
GB 14536.11-2008
| Valid |
GB 14536.11-2008
|
GB 14536.11-1996 | English | 279 |
Add to Cart
|
3 days
|
Automatic electrical controls for household and similar use. Particular requirements for electricaly perated modor starting relays
|
GB 14536.11-1996
| Obsolete |
GB 14536.11-1996
|
Buy with any currencies (Euro, JPY, KRW...): GB 14536.11-2008 Preview this PDF: GB 14536.11-2008
GB 14536.11-2008: PDF in English GB 14536.11-2008
Automatic electrical controls for household and similar use.Particular requirements for motor-starting relays
ICS 29.130.20
K32
National Standards of People's Republic of China
GB 14536.11-2008/IEC 60730-2-10.2006
Replacing GB 14536.11-1996
Household and similar electrical automatic controller
Particular requirements for motor starting relays
(IEC 60730-2-10.2006, IDT)
Posted 2008-12-30
2010-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
IEC Introduction Ⅴ
1 Scope and normative references 1
2 Definitions 1
3 General requirements 1
4 General notes 2
Rating 2 5
6 Category 2
7 Profile 2
8 Protection against electric shock 2
9 ground protection measures 2
10 Terminals and terminations 2
11 structural requirements 3
12 moisture and dust 3
13 Electric strength and insulation resistance 3
14 heat 3
15 Manufacturing deviation and drift 3
3 16 Environmental Stress
Durability 17 3
The mechanical strength of 18 3
19 Threaded parts and connections 3
20 creepage distances, clearances and distances through solid insulation through 3
21 heat, fire and resistance to tracking 3
Corrosion resistance of 22 3
23 Electromagnetic compatibility (EMC) emission requirements --- 4
24 assembly 4
25 Normal operation 4
26 Electromagnetic compatibility (EMC) requirements --- immunity 4
27 non-normal operation 4
28 Guidelines for the use of electronic disconnect 4
Figure 5
Appendix 6
Annex C (normative) mercury switch test cotton 6
Appendix E (normative) leakage current measurement circuit 6
Annex H (normative) requirements for electronic controllers 7
GB 14536.11-2008/IEC 60730-2-10.2006
Foreword
All technical content in this section is mandatory.
GB 14536 "Household and similar electrical automatic controller" is divided into two parts.
--- Part 1. General requirements;
--- Part 2. Particular requirements.
Special requirements and consists of the following components.
--- GB 14536.3 - Particular requirements for thermal motor protectors (IEC 60730-2-2, IDT);
--- Particular requirements GB 14536.4 tubular fluorescent lamp ballasts for thermal protectors (IEC 60730-2-3, IDT);
--- GB 14536.5 sealed and semi-hermetic motor - compressor motor thermal protection Particular requirements (IEC 60730-2-4,
IDT);
--- Particular requirements GB 14536.6 automatic electrical burner control systems (IEC 60730-2-5, IDT);
--- GB 14536.7 pressure sensitive electrical controls - Particular requirements (idt IEC 60730-2-6);
--- GB 14536.8 Particular requirements for timers and time switches (idt IEC 60730-2-7);
--- GB 14536.9 Particular requirements for electrically operated water valves (including mechanical requirements) (IEC 60730-2-8, IDT);
--- GB 14536.10 - Particular requirements for temperature sensing controls (IEC 60730-2-9, IDT);
--- GB 14536.11 Particular requirements for motor starting relays (IEC 60730-2-10, IDT) used;
--- GB 14536.12 Particular requirements for energy regulators (idt IEC 60730-2-11);
--- GB 14536.13 Particular requirements for electrically operated door locks (IEC 60730-2-12, IDT);
--- GB 14536.15 Particular requirements for humidity sensing controls (IEC 60730-2-13, IDT);
--- GB 14536.16 Particular requirements for electric actuators (idt IEC 60730-2-14);
--- GB 14536.17 special requirements of the float or electrode-sensitive automatic electrical water level sensing controller used in the boiler appliance
(IEC 60730-2-15, IDT);
--- GB 14536.18 - Particular requirements for household and similar use of the float type level controllers (IEC 60730-2-16, IDT);
--- GB 14536.19 Particular requirements for electrically operated gas valves, including mechanical requirements (IEC 60730-2-17, IDT);
--- GB 14536.20 Particular requirements for water and air flow sensing controls, including mechanical requirements (IEC 60730-2-18, IDT);
--- GB 14536.21 Particular requirements for electrically operated oil valves, including mechanical requirements (IEC 60730-2-19, IDT);
This section identical with IEC 60730-2-10.2006 "Household and similar electrical controls - Part 2. motor starting
Particular requirements for the relay. "
Part of this structure with IEC 60730-2-10.2006 same. In this section, there is a corresponding national standards, national standards incorporated by reference
Quasi; no national standards, IEC standards are incorporated by reference outlined.
For ease of use, this section made the following editorial changes.
a) "This standard" be replaced by "this section";
b) use a decimal point instead of a decimal comma ",". ",";
c) increase the national standard foreword.
This part of GB 14536.1-2008 "Household and similar electrical controls - Part 1. General requirements" in conjunction.
This Part replaces GB 14536.11-1996 "Household and similar electrical controls for motor starting relays to
begging".
Compared with GB 14536.11-1996 part of the main changes are as follows.
GB 14536.11-2008/IEC 60730-2-10.2006
--- Several sections according to the change of the name of GB 14536.1 made the appropriate changes;
--- Chapter 1 apply to rated voltage range according to the general asked to do modified accordingly;
--- Chapter 27 of the test contents are different;
Appendix H --- changing requirements.
This part of the Annex C, Annex E and Annex H normative appendix.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee household automatic control (SAC/TC212) centralized.
This section is drafted. Guangzhou CVC Testing Institute, Guangzhou Electric Apparatus Research Institute, Wanbao Refrigeration Group Guangzhou Electrical Appliance Co.,
Division Hangzhou Star Shuai Seoul Electric Co., Ltd. Foshan Tongbao, Lanxi City, the Electric Appliance Co., Ltd. Zhejiang Yan thermostat limited
The company, Shunde District of Foshan City, Yung your measurement Electric Co. Ltd., China Household Electrical Appliances Research Institute.
Drafters of this section. Core hole Xun, Zhu Liping, Huang Kaiyun, Huang Zhi Hang, Lu Wencheng, wheat harvest, high Yonghua, Chen Yonglong, Hedun Qi, Gu Yulin.
This part of the standard replaces the previous editions are.
--- GB 14536.11-1996.
GB 14536.11-2008/IEC 60730-2-10.2006
IEC Foreword
1) IEC (International Electrotechnical Commission) is a worldwide standardization group composed of national electrotechnical committees (IEC National Committees)
Organizations. The object of IEC is to promote international cooperation on issues related to the standardization of the electrical and electronic fields. For this purpose
IEC addition to other activities, but also publishes International Standards, technical specifications, technical reports, public specification (PAS, Publicly
AvailableSpecifications) and guidelines (henceforth referred to IEC publication). Their preparation is entrusted to technical
Commission to complete. As a member of IEC National Committees, as long as the interest of the standard to be developed, may participate
Its formulation. Liaising with the IEC 's international, official or unofficial organizations are also involved in the development of standards.
IEC and the World Organization for Standardization (ISO ) in accordance with the conditions specified in the agreement, close cooperation.
2) since each technical committee has representatives from the National Commission on the relevant issues of interest, so the IEC on technical
Issue formal decisions or agreements on the maximum expression of the international consensus on the relevant issues.
3) IEC Publications have the form of recommendations for international use, and accepted by the National Committees in that sense. Despite being made
There are possible effort to ensure that the technical content of IEC publications is correct, IEC these publications can not be used
Way or misinterpretation of any user and responsibility.
4) In order to promote international unification, IEC National Committees in charge of the IEC international standards transparently converted to the maximum extent possible
National or regional standards. Between the IEC Standard and the corresponding national or regional standard if there is any difference, it should be converted into the standard
After clearly illustrates.
5) IEC did not develop any signs of approval procedure, when a device if it complies with the IEC declared a publication, which is not IEC
Accountable.
6) All users should make sure you have the latest version of this publication.
7) IEC or its leaders, employees, servants or agents, including independent experts and IEC technical committees, national committee
Members will, for the use of any person or the trust of the IEC standards or other IEC publication caused casualties, property damage
Loss or other damage to the natural environment (whether such losses are direct or indirect) does not bear any responsibility for the phase
Should produce costs and expenses (including legal fees) is not liable.
8) To take note of the standard referenced standards. Use the referenced standard is correct application of this standard essential.
9) It is noteworthy that this International Standard may involve some parts of the patent. IEC for the identification of some or all of this
A Class of the patent will be irresponsible.
IEC 60730-2-11 by the IEC Technical Committee TC72. home automation controller developed.
This second edition cancels and replaces the first edition in 1994 and its amendments 1 and 2001 amendments enacted in 1991 2. The second edition
Constitute a technical revision and update of the standard to meet the current practice while also parallel with the use of the standard.
Standard text based on the following documents.
FDIS Report on voting
72/711/FDIS 72/724/RVD
For more information on this standard a vote, the vote on the report, see the table below.
Drafting of the publication to comply with ISO /IEC Guide. Part II.
The second part of the book used in conjunction with IEC 60730-1. This requirement was established in 1999, the third edition of IEC 60730-1 and
2003 Amendment 1 basis. IEC 60730-1 should be considered in subsequent versions or revisions.
This part supplements or modifies the corresponding provisions in IEC 60730-1 so as to be converted to the corresponding IEC standards. motor starting relay
Particular requirements for electrical appliances.
GB 14536.11-2008/IEC 60730-2-10.2006
When appearing in this part of the "addition", "modification" or "replacement", the general requirements of the relevant requirements, test description or explanatory content should
Be amended accordingly.
When no change, this section will indicate the appropriate sections or provisions apply.
In the development of a full international standard, we must consider the different requirements of the actual situation of the various regions of the world is formed, and should be recognized
Differences in each country's electrical systems and wiring rules.
Use the following printed in this section.
--- Body requirements. roman;
--- Test specifications. italic;
--- Note matters. small roman type.
For the first part of sub-clause is part of the newly added, comments, or items shown are numbered starting from 101, and the newly added Appendix
Places letters AA, BB starts.
All belong to the IEC 60730 series, attributable to the standard, "household and similar use automatic controller" category list, you can IEC
Get on the website.
The Committee decided that the contents of this publication in the IEC 's website http. // webstore. iec. On ch marked, and specific publications related
Remain unchanged before the next revision date. And to this date, the publication will be.
● reconfirmed;
● Cancel;
● The revised version of the substitution; or
● Amendment.
GB 14536.11-2008/IEC 60730-2-10.2006
Household and similar electrical automatic controller
Particular requirements for motor starting relays
1 Scope and normative references
GB 14536.1 of the chapter is applicable except as follows.
1.1 Replacement.
This section applies to household and similar equipment with automatic control of single-phase motor starting control winding.
This section applies to use NTC or PTC thermistor motor starting relays, the corresponding requirements of Appendix J.
1.1.1 This section applies to the inherent safety Automatic electrical controls for safety equipment and related operating values, operating time and operating procedures
Sequence, starting relays and test applies to household or similar device or equipment used in conjunction with an electric motor.
Not as a general household, but for the public, such as equipment shops, light industry and farm use by non-professionals, the use of
Motor starting relays are also included within the scope of this.
This part is not designed solely for the purpose of industrial motors use starting relays.
Note. "device" in this section use the term with "utensils and equipment." The term "start relay" means "motor starting relays."
1.1.2 This section applies to an electronic device equipped with the starter relay, also apply to the use of a thermistor element, from the element and the magnetic elements
Relay.
1.1.3 This section does not apply to general purpose relays or contactors within the GB 14048 series range, the motor starter. This section
Does not apply to electrical and mechanical timers mechanically operated starter.
1.1.4 This section applies to those in the manual control or mechanically and electrically starter relay combination.
Manual switch request does not constitute a part of the starter is contained in the GB 15092.1.
1.2 Replacement.
This section applies to the rated voltage not exceeding 690V, rated current not exceeding 63A of the starter relay.
1.3 Replacement.
This section considered response depends on the starter relay in the device mounting method of automatic operation. If the response to make to protect
Wearer and the surrounding environment meaningful response by the manufacturer or by the determination of the appropriate equipment standard values apply.
1.4 Replacement.
This section also applies to the starter relay with electronic devices, the corresponding requirements of Annex H.
2 Definitions
GB 14536.1 of the chapter is applicable except as follows.
2.2 is defined by use classification controller
Addition of provisions.
2.2.101
Booking is integral to the appliance or load, for controlling the primary winding of the motor and the auxiliary circuit is connected to the start winding up
To start for household and similar appliances used in single-phase motor controller electrically operated.
Note. In general, the motor starting relays will provide Type 1 action.
3 General requirements
GB 14536.1 of this chapter shall apply.
GB 14536.11-2008/IEC 60730-2-10.2006
General Description 4 Test
GB 14536.1 of this chapter shall apply.
5 RATINGS
GB 14536.1 of this chapter shall apply.
Category 6
GB 14536.1 of the chapter is applicable except as follows.
6.3 By Application
Addition of provisions.
6.3.101 --- motor starting relays.
6.3.101.1 --- voltage sensitive.
6.3.101.2 --- current sensitive.
6.3.101.3 --- PTC.
6.3.101.4 --- Thermal.
6.13 The press resistant insulating material tracking index (PTI) value classification
6.13.1 Not applicable.
6.15 Classification by structure
instead.
6.15 Integral mount or formula
6.15.1 --- electrons.
6.15.2 --- electromagnetic.
6.15.3 --- PTC thermistor.
6.15.4 --- Thermal.
NOTE. Although referred to in 6.15.2 to 6.15.4 relay the main structure does not belong to the electronic structure, but which may be equipped with internal electronic components.
7 Information
GB 14536.1 of the chapter is applicable except as follows.
Table 7.2
increase.
Information chapter, strip method
101 motor stable running current 14.4 X
8 Protection against electric shock
GB 14536.1 of this chapter shall apply.
9 ground protection measures
GB 14536.1 of this chapter shall apply.
10 Terminals and terminations
GB 14536.1 of this chapter shall apply.
GB 14536.11-2008/IEC 60730-2-10.2006
11 structural requirements
GB 14536.1 of this chapter shall apply.
12 moisture and dust
GB 14536.1 of this chapter shall apply.
13 Electric strength and insulation resistance
GB 14536.1 of this chapter shall apply.
Fever 14
GB 14536.1 of the chapter is applicable except as follows.
14.4 Replacement.
1.06 times the motor is applied in Table 7.2 101 declared starter relay coil motor steady-state operating current. Should contact
Not loaded.
14.4.3.1 Not applicable.
14.4.3.2 Not applicable.
15 Manufacturing deviation and drift
GB 14536.1 of this chapter shall apply.
16 Environmental Stress
GB 14536.1 of this chapter shall apply.
17 Durability
GB 14536.1 of the chapter is applicable except as follows.
17.9 ~ 17.13 NA.
18 Mechanical strength
GB 14536.1 of this chapter shall apply.
19 Threaded parts and connections
GB 14536.1 of this chapter shall apply.
20 creepage distances, clearances and distances through solid insulation through
GB 14536.1 of this chapter shall apply.
21 heat, fire and tracking resistance
GB 14536.1 of this chapter shall apply.
22 corrosion resistance
GB 14536.1 of this chapter shall apply.
GB 14536.11-2008/IEC 60730-2-10.2006
23 Electromagnetic compatibility (EMC) emission requirements ---
GB 14536.1 of this chapter shall apply.
24 components
GB 14536.1 of this chapter shall apply.
25 normal operation
GB 14536.1 of this chapter shall apply.
26 Electromagnetic compatibility (EMC) requirements --- immunity
GB 14536.1 of this chapter shall apply.
27 non-normal operation
GB 14536.1 of the chapter is applicable except as follows.
increase.
27.2 Burning Test
Modify interpretation section.
Note. For motor starting relays, successful completion of the test Chapter 17 is considered to meet the terms.
instead.
27.3 overvoltage and undervoltage test
Not applicable.
28 Guidelines for the use of electronic disconnection
GB 14536.1 of this chapter shall apply.
GB 14536.11-2008/IEC 60730-2-10.2006
Fig GB 14536.1 FIG apply.
GB 14536.11-2008/IEC 60730-2-10.2006
appendix
GB 14536.1 Appendix, is applicable except as follows.
Appendix C
(Normative)
Mercury switch test cotton
Not applicable.
Appendix E
(Normative)
Leakage current measurement circuit
Not applicable.
GB 14536.11-2008/IEC 60730-2-10.2006
Appendix H
(Normative)
Requirements for electronic controllers
GB 14536.1 of the appendix, is applicable except as follows.
H. 17 Durability
GB 14536.1 of the chapter is applicable except as follows.
H. 17.1.4.2 Thermal cycling test
a) cycle
instead.
Test period 18d.
H. 26 Electromagnetic compatibility (EMC) requirements --- immunity
GB 14536.1 of the chapter is applicable except as follows.
H. 26.2.1 Replacement.
For motor starting relays, meets the requirements, by H. 26.8 and H. The test was 26.9.
Note. The motor starting relays, H. 26.4 and H. 26.9 Other disturbances will not result in inherently dangerous. Changes inherent dangers and output from
Other tests of this standard to evaluate.
increase.
H. 26.9.101 test program
Controller 5 tests.
H. Replace the first paragraph 26.13.2 an explanation.
Note. The test allows the controller is no longer operational. Subject to the second option, the acceptability of the declared output must be in the final product
Assessment to determine this output does not cause unsafe operation.
GB 14536.11-2008/IEC 60730-2-10.2006
......
Standard ID | GB 14536.11-2008 (GB14536.11-2008) | Description (Translated English) | [GB/T 14536.11-2008] Automatic electrical controls for household and similar use. Particular requirements for motor-starting relays | Sector / Industry | National Standard | Classification of Chinese Standard | K32 | Classification of International Standard | 29.130.20 | Word Count Estimation | 15,170 | Date of Issue | 2008-12-30 | Date of Implementation | 2010-02-01 | Older Standard (superseded by this standard) | GB 14536.11-1996 | Quoted Standard | GB 14536.1 | Adopted Standard | IEC 60730-2-10-2006, IDT | Drafting Organization | Guangzhou Institute of CVC detection technology | Administrative Organization | National Standardization Technical Committee of home automation controller | Regulation (derived from) | Announcement of Newly Approved National Standards No. 26 of 2008 (total 139) | Proposing organization | China Electrical Equipment Industry Association | Issuing agency(ies) | Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China | Summary | This Chinese standard applies to equipment for household and similar use automatic control of single-phase motor start-winding controller. This standard applies to an NTC or PTC thermistors motor starting relays, the corresponding requirements in Appendix J. 1. 1. 1 this standard applies to the inherent safety Automatic electrical controls for safety -related operations and equipment value, the operating time and operating procedures, as well as for the home or similar device, or with the device used motor starting relays tests. Not intended for normal household, but are used in public places such as shops, light industry and farms by non-professionals use equipment, the use of motor starting relays are also included within the scope of this standard. This standard is not designed for industrial purposes for motor starting relays. Note: this standard uses the"device"encompasses"appliances and equipment. "Starter relay"means that"motor starting relays. "1. 1. 2 this standard applies to the starter relay is equipped with electronic devices, also apply to the use of a thermistor element, heating elements and magnetic components starter relay. 1. 1. 3 this standard does not apply to GB 14048 series within the scope of general purpose relays or contactors, motor starters. This standard does not apply to mechanical timers and mechanical operation of the electric starter. 1. 1. 4 this standard applies to those who are electrically or mechanically combined with the starter relay manual controller. Does not constitute a part of the starter of the manual switch in the request contained in GB15092. 1 |
|